Analysis of complex protein mixtures with improved sequence coverage using (CE-MS/MS)n

被引:41
|
作者
Garza, Selynda [1 ]
Moini, Mehdi [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
D O I
10.1021/ac0612269
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)(n), which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)(n) can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)(n) is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes similar to 10 min; therefore, several subanalyses can be performed in similar to 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)(n) using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)(n) is performed by scanning a narrow mass range (every similar to 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of similar to 26 000 (standard I), a six-protein mixture with an average MW similar to 49 000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In similar to 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respctively.
引用
收藏
页码:7309 / 7316
页数:8
相关论文
共 50 条
  • [21] Analysis of benzodiazepines in dynamically coated capillaries by CE-DAD, CE-MS and CE-MS2
    Vanhoenacker, G
    de l'Escaille, F
    De Keukeleire, D
    Sandra, P
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (03) : 595 - 606
  • [22] Enantioselective CE-MS analysis of ketamine metabolites in urine
    Sandbaumhuter, Friederike A.
    Aerts, Jordan T.
    Theurillat, Regula
    Andren, Per E.
    Thormann, Wolfgang
    Jansson, Erik T.
    ELECTROPHORESIS, 2023, 44 (1-2) : 125 - 134
  • [23] Combination of LC-MS and CE-MS analysis for the separation and the identification of phosphonic acids
    Mercier, JP
    Morin, P
    Dreux, M
    CHIMIA, 1999, 53 (10) : 511 - 514
  • [24] Reproducibility Evaluation of Urinary Peptide Detection Using CE-MS
    Mavrogeorgis, Emmanouil
    Mischak, Harald
    Latosinska, Agnieszka
    Siwy, Justyna
    Jankowski, Vera
    Jankowski, Joachim
    MOLECULES, 2021, 26 (23):
  • [25] CE-microreactor-CE-MS/MS for protein analysis
    Schoenherr, Regine M.
    Ye, Mingliang
    Vannatta, Michael
    Dovichi, Norman J.
    ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2230 - 2238
  • [26] Multiple enzymatic digestion for enhanced sequence coverage of proteins in complex proteomic mixtures using capillary LC with ion trap MS/MS
    Choudhary, G
    Wu, SL
    Shieh, P
    Hancock, WS
    JOURNAL OF PROTEOME RESEARCH, 2003, 2 (01) : 59 - 67
  • [27] On-line coupling of SPE and CE-MS for peptide analysis
    Tempels, F. W. Alexander
    Underberg, Willy J. M.
    Somsen, Govert W.
    de Jong, Gerhardus J.
    ELECTROPHORESIS, 2007, 28 (09) : 1319 - 1326
  • [28] Use of organic solvent to prevent protein adsorption in CE-MS experiments
    Staub, Aline
    Comte, Sylvain
    Rudaz, Serge
    Veuthey, Jean-Luc
    Schappler, Julie
    ELECTROPHORESIS, 2010, 31 (19) : 3326 - 3333
  • [29] CE-MS for the analysis of intact proteins 2010-2012
    Haselberg, Rob
    de Jong, Gerhardus J.
    Somsen, Govert W.
    ELECTROPHORESIS, 2013, 34 (01) : 99 - 112
  • [30] Analysis of acid dye degradation products by CE-MS and HPLC
    Lu, Yiping
    Hardin, Ian R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1573 - U1573