Evaluation of fatty liver fibrosis in rabbits using real-time shear wave elastography

被引:27
|
作者
Lu, Yongping [1 ]
Wei, Jia [2 ]
Tang, Yueyue [1 ]
Yuan, Yuan [1 ]
Huang, Yanling [1 ]
Zhang, Yong [1 ]
Li, Yunyan [1 ]
机构
[1] Kunming Med Univ, Peoples Hosp Yunnan Prov 2, Affiliated Hosp 4, Dept Ultrasound, Kunming 650021, Yunnan, Peoples R China
[2] Kunming Med Univ, Peoples Hosp Yunnan Prov 2, Affiliated Hosp 4, Liver Dis Ctr, Kunming 650021, Yunnan, Peoples R China
关键词
real-time shear wave elastography; rabbit; fatty liver; elasticity; VIVO SOFT-TISSUE; NONALCOHOLIC STEATOHEPATITIS; HEPATITIS-C; NONINVASIVE ASSESSMENT; DISEASE; DIAGNOSIS; BIOPSY; SYSTEM;
D O I
10.3892/etm.2014.1749
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to detect the elastic modulus (stiffness) of the livers of rabbits with non-alcoholic and alcoholic fatty liver disease using real-time shear wave elastography (SWE), and to investigate the fibrosis development process in the formation of fatty liver. The stiffness of the fatty livers in rabbit models prepared via feeding with alcohol or a high-fat diet were measured using a real-time SWE ultrasound system and a 4-15-MHz linear array probe, and the liver stiffness was compared with the pathological staging of the disease. The stiffness of the liver was positively correlated with the degree of pathological change in fatty liver disease (P<0.01). The stiffness of the liver in the alcoholic fatty liver group was higher compared with that in the non-alcoholic fatty liver and control groups, and the stiffness in the non-alcoholic fatty liver group. was higher than that in the control group (P<0.01). Real-time SWE objectively identified the trend in the changing stiffness of the liver and noninvasively detected the development of fibrosis in the progression of non-alcoholic and alcoholic fatty liver disease.
引用
收藏
页码:355 / 362
页数:8
相关论文
共 50 条
  • [31] Real-time ultrasound shear wave elastography using a local phase gradient
    Gonzalez-Mateo, Enrique
    Camarena, Francisco
    Jimenez, Noe
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2025, 260
  • [32] Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis
    Fu, Juan
    Wu, Biao
    Wu, Huazhi
    Lin, Feng
    Deng, Wei
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [33] Comparison of strain elastography and shear wave elastography in diagnosis of fibrosis in nonalcoholic fatty liver disease
    Ogino, Yu
    Wakui, Noritaka
    Nagai, Hidenari
    Matsuda, Takahisa
    JOURNAL OF MEDICAL ULTRASONICS, 2023, 50 (02) : 187 - 195
  • [34] Comparison of strain elastography and shear wave elastography in diagnosis of fibrosis in nonalcoholic fatty liver disease
    Yu Ogino
    Noritaka Wakui
    Hidenari Nagai
    Takahisa Matsuda
    Journal of Medical Ultrasonics, 2023, 50 : 187 - 195
  • [35] Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis
    Juan Fu
    Biao Wu
    Huazhi Wu
    Feng Lin
    Wei Deng
    BMC Medical Imaging, 20
  • [36] Open questions in the assessment of liver fibrosis using real-time elastography - Reply
    Saftoiu, Adrian
    Gheonea, Dan Ionut
    Ciurea, Tudorel
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) : W372 - W373
  • [37] Liver fibrosis grading using multiresolution histogram information in real-time elastography
    Albouy-Kissi, A.
    Sarry, L.
    Massoulier, S.
    Bonny, C.
    Randl, K.
    Abergel, A.
    MEDICAL IMAGING 2010: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2010, 7629
  • [38] Liver Fibrosis Evaluation Using Real-time Shear Wave Elastography in Hepatitis C-Monoinfected and Human Immunodeficiency Virus/Hepatitis C-Coinfected Patients
    Verlinden, Wim
    Bourgeois, Stefan
    Gigase, Pierre
    Thienpont, Clara
    Vonghia, Luisa
    Vanwolleghem, Thomas
    Michielsen, Peter
    Francque, Sven
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (06) : 1299 - 1308
  • [39] Analysis of transient shear wave generation for real-time elastography
    Yagi, S
    Sanuga, A
    Kondo, Y
    Tamura, K
    Sato, A
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1356 - 1359
  • [40] Real-Time Shear Wave Elastography for Determining the Ideal Site of Liver Biopsy in Diffuse Liver Disease
    Patidar, Yashwant
    Singh, Jitender
    Chatterjee, Navojit
    Mukund, Amar
    Rastogi, Archana
    Kumar, Guresh
    Sharma, Manoj Kumar
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (01): : 44 - 53