Performance analysis of a dielectric based 3D building integrated concentrating photovoltaic system

被引:87
|
作者
Baig, Hasan [1 ]
Sellami, Nazmi [1 ]
Chemisana, Daniel [2 ]
Rosell, Joan [2 ]
Mallick, Tapas K. [1 ]
机构
[1] Univ Exeter, Environm & Sustainabil Inst, Penryn TR10 9FE, Cornwall, England
[2] Univ Lleida, Lleida, Spain
基金
英国工程与自然科学研究理事会;
关键词
3DCCPC; Non-uniform; CPV; BiCPV; CPC; COMPOUND PARABOLIC CONCENTRATOR; SOLAR-CELLS; MODULES;
D O I
10.1016/j.solener.2014.03.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The use of concentrating photovoltaic systems (CPV) in building integration has spurred towards the development of newer products, which have the potential to offer the convenience of pleasing architecture and day lighting along with simultaneous production of clean energy. This paper addresses the energy transformations and the expected energy output of a low concentrating photovoltaic system designed to have a geometric concentration of 3.6 x. The optical element used is a three dimensional Cross Compound Concentrator (3DCCPC) made from clear polyurethane material. Small sized silicon solar cells based on the Laser Grooved Buried Contact (LGBC) technology having an absorber area of 1 cm(2) are utilised in the system. Both experimental and numerical analyses are performed confirming the optical, electrical and thermal performance of the system. While performing the optical analysis the concentrator was found to have a maximum optical efficiency of 73.4%. A maximum power ratio of 2.67 was observed when comparing the electrical output of the concentrator unit with a non-concentrating counterpart. The effects of non-uniformity caused by the use of the concentrator are analysed. The non-uniformity of flux distribution showed an average drop of 2.2% in the I-sc values which is again reflected in the overall power output. Manufacturing defects like the cell and concentrator misalignments are addressed and their impact on the overall performance are verified by numerical simulations. The operating temperature of the solar cells was found to have a parasitic effect on the overall performance of the system. A maximum temperature of 332 K was observed in the solar cell at 0 degrees incidence and a incoming radiation of 1000 W/m(2) which brings down the overall power production by 14.6%. Finally, the expected system output over a given time period is presented showing the strengths and weakness while employing such a system. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:525 / 540
页数:16
相关论文
共 50 条
  • [31] Evaluation of the smart daylighting control performance of the concentrating photovoltaic/daylighting system as the skylight in the building
    Xuan, Qingdong
    Li, Guiqiang
    Zhao, Bin
    Jiang, Bin
    Sun, Dongfang
    Zhang, Xiuping
    Tang, Jingchun
    Zhuang, Yuan
    Liu, Jie
    Li, Lao
    Solar Energy, 2022, 238 : 17 - 29
  • [32] Evaluation of the smart daylighting control performance of the concentrating photovoltaic/daylighting system as the skylight in the building
    Xuan, Qingdong
    Li, Guiqiang
    Zhao, Bin
    Jiang, Bin
    Sun, Dongfang
    Zhang, Xiuping
    Tang, Jingchun
    Zhuang, Yuan
    Liu, Jie
    Li, Lao
    SOLAR ENERGY, 2022, 238 : 17 - 29
  • [33] Performance analysis of a mirror symmetrical dielectric totally internally reflecting concentrator for building integrated photovoltaic systems
    Muhammad-Sukki, Firdaus
    Abu-Bakar, Siti Hawa
    Ramirez-Iniguez, Roberto
    McMeekin, Scott G.
    Stewart, Brian G.
    Munir, Abu Bakar
    Yasin, Siti Hajar Mohd
    Rahim, Ruzairi Abdul
    APPLIED ENERGY, 2013, 111 : 288 - 299
  • [34] Performance analysis and optimization of insulation layers on a novel building-integrated photovoltaic system
    Zhang, Yaxi
    Zhu, Na
    Yu, Zhongyi
    Zhu, Zishang
    Luo, Zhenyu
    Zhao, Xudong
    ENERGY AND BUILDINGS, 2024, 320
  • [35] Performance evaluation of a building integrated photovoltaic array using an internet based monitoring system
    Dirks, E.
    Gole, A. M.
    Molinski, T. S.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 3453 - +
  • [36] Electrical and Thermal Performance Analysis for a Highly Concentrating Photovoltaic/Thermal System
    Xu, Ning
    Ji, Jie
    Sun, Wei
    Huang, Wenzhu
    Jin, Zhuling
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2015, 2015
  • [37] Optical performance analysis of immersion cooling liquid in concentrating photovoltaic system
    聚光光伏系统中浸没冷却液体的光学性能分析
    Han, Xinyue (hanxinyue123456@163.com), 1630, Science Press (39):
  • [38] Design, fabrication and outdoor performance analysis of a low concentrating photovoltaic system
    Sarmah, Nabin
    Mallick, Tapas K.
    SOLAR ENERGY, 2015, 112 : 361 - 372
  • [39] Performance analysis of a multiple chamber trough concentrating photovoltaic/thermal system
    Chang, Ze-Hui
    Zheng, Hong-Fei
    Hou, Jing
    Dai, Jing
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2012, 32 (09): : 915 - 920
  • [40] Long term performance analysis of low concentrating photovoltaic (LCPV) systems for building retrofit
    Parupudi, Ranga Vihari
    Singh, Harjit
    Kolokotroni, Maria
    Tavares, Jose
    APPLIED ENERGY, 2021, 300