Adequacy of dialysis

被引:0
|
作者
Ikizler, TA [1 ]
Schulman, G [1 ]
机构
[1] VANDERBILT UNIV, MED CTR, DEPT MED, DIV NEPHROL, NASHVILLE, TN 37232 USA
关键词
dialysis adequacy; end-stage renal disease; morbidity in dialysis; kinetic modeling;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Despite improvements in the delivery of dialysis, morbidity and mortality remain excessively high in end-stage renal disease patients. Multiple lines of evidence suggest that inadequate dialysis is responsible these trends. The limits of our understanding of the influence of dialysis dose on mortality and morbidity are discussed. In that context, the relationship between dialysis dose and nutritional status of dialysis patients is also reviewed. The best marker for adequacy of dialysis is yet to be determined. However, urea as a surrogate for small molecular weight solute clearance, has been demonstrated by many studies to be a parameter of adequacy, both in hemodialysis and peritoneal dialysis populations. The application of kinetic modeling of urea is discussed far hemodialysis. The new insights that will be forthcoming at the conclusion of the National Institute of Health HEMO study should help to define an optimal dose of dialysis.
引用
收藏
页码:S96 / S100
页数:5
相关论文
共 50 条
  • [31] Focusing on peritoneal dialysis adequacy
    Issad, Belkacem
    Durand, Pierre-Yves
    Siohan, Pascale
    Goffin, Eric
    Cridlig, Joelle
    Jean, Guillaume
    Ryckelynck, Jean-Philippe
    Arkouche, W.
    Bourdenx, J. -P.
    Cridlig, J.
    Dallaporta, B.
    Fessy, H.
    Fischbach, M.
    Giaime, P.
    Goffin, E.
    Issad, B.
    Jean, G.
    Joly, D.
    Mercadal, L.
    Poux, J. -M.
    Ryckelynck, J. -P.
    Siohan, P.
    Souid, M.
    Toledano, D.
    Verger, C.
    Vigeral, P.
    Uzan, M.
    NEPHROLOGIE & THERAPEUTIQUE, 2013, 9 (06): : 416 - 425
  • [32] ADEQUACY OF DIALYSIS AND PROLONGED REUSE
    PEREZGROVAS, H
    HERRERAACOSTA, J
    CURRENT THERAPY IN NEPHROLOGY, 1989, 24 : 346 - 348
  • [33] ADEQUACY AND LENGTH OF DIALYSIS TREATMENT
    LEVIN, N
    DIALYSIS & TRANSPLANTATION, 1993, 22 (01) : 55 - 55
  • [34] Adequacy targets in peritoneal dialysis
    Gokal, R
    Chan, CK
    JOURNAL OF NEPHROLOGY, 2004, 17 : S55 - S57
  • [35] ADEQUACY OF PERITONEAL-DIALYSIS
    CHURCHILL, DN
    THORPE, K
    TAYLOR, DW
    KESHAVIAH, P
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 439 - 439
  • [36] Dialysis adequacy and high transporters
    Heaf, J
    PERITONEAL DIALYSIS INTERNATIONAL, 1997, 17 (04): : 412 - 412
  • [37] ADEQUACY OF DIALYSIS - A CRITICAL ANALYSIS
    VANHOLDER, RC
    RINGOIR, SM
    KIDNEY INTERNATIONAL, 1992, 42 (03) : 540 - 558
  • [38] Evolution of the technique and adequacy of dialysis
    Botella, J
    NEFROLOGIA, 1996, 16 : 43 - 49
  • [39] Assessing adequacy of peritoneal dialysis
    Hiroshige, K
    Kanegae, K
    Ohtani, A
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (07): : 471 - 473
  • [40] Adequacy and a New Era for Dialysis
    Oreopoulos, Dimitrios G.
    DIALYSIS & TRANSPLANTATION, 2011, 40 (10) : 433 - 433