ICP-MS Detection for HPLC Analyses of Pharmaceutical Products

被引:0
|
作者
Shelbourn, Tim [1 ]
Williamson, Leah [2 ]
Gillespie, Todd [1 ]
Montgomery, Robert [1 ]
机构
[1] Eli Lilly & Co, Indianapolis, IN 46285 USA
[2] Univ Georgia, Athens, GA 30602 USA
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; FAT-SOLUBLE VITAMINS;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Experiments using inductively coupled plasma-mass spectrometry (ICP-MS) as a detection system for reversed-phase chromatographic methods have been conducted for the analyses of various pharmaceutical compounds. Interfacing the ICP-MS instrument to the high performance liquid chromatography (HPLC) system was straightforward. The eluent from the HPLC column was pumped through a photodiode array (PDA) and then directly into the ICP-MS nebulizer using standard sample introduction components at flow rates ranging from 0.5 to 1.5 mL/min. Two separate sets of experiments were carried out. Initial speciation experiments were conducted on the B supplements cyanocobalamin (vitamin 11312), biotin, and thiamine (vitamin B-1)using isocratic separations. ICP-MS chromatograms were generated by monitoring cobalt at m/z 59, phosphorus at m/z 31, and sulfur at m/z 34 simultaneously. Linear regression data were obtained for cyanocobalamin, thiamine hydrochloride, and biotin. Elemental detection was used to resolve coeluted thiamine and cyanocobalamin peaks in a rapid isocratic separation. The signal for biotin in the sulfur chromatogram was determined to be much larger than that of the corresponding UV chromatogram at 250 nm. In the second set of experiments, an active pharmaceutical ingredient (API) was hydrolyzed with base to monitor the parent compound and two degradation products: degradation product 1 (DP1) and degradation product 2 (DP2). The API molecule contains bromine, chlorine, and sulfur; DP1 contains bromine and sulfur; and DP2 contains chlorine. The ions monitored for analysis of API, DP1, and DP2 were m/z 79 for bromine, m/z 35 for chlorine, and m/z 34 for sulfur. The calculation of relative amounts of API, DP1, and DP2 from the bromine, chlorine, and sulfur chromatograms was performed. The data suggest that the same calculation performed from the UV chromatogram introduces a bias due to the difference in extinction coefficients for each compound. The capacity for monitoring UV absorbance and elemental ions sequentially was demonstrated to provide enhanced analytical specificity without requiring interpretation of complex mass spectra.
引用
收藏
页码:164 / +
页数:7
相关论文
共 50 条
  • [41] Development of a new HPLC method for the determination of inorganic and methylmercury in biological samples with ICP-MS detection
    Vallant, Birgit
    Kadnar, Rainer
    Goessler, Walter
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (03) : 322 - 325
  • [42] Selenium speciation analysis of selenium-enriched supplements by HPLC with ultrasonic nebulisation ICP-MS and electrospray MS/MS detection
    Infante, HG
    O'Connor, G
    Rayman, M
    Wahlen, R
    Entwisle, J
    Norris, P
    Hearn, R
    Catterick, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) : 1529 - 1538
  • [43] Comparative Evaluation of GFAAS and ICP-MS for Analyses of Cadmium in Blood
    Fukui, Yoshinari
    Ohashi, Fumiko
    Sakuragi, Sonoko
    Moriguchi, Jiro
    Ikeda, Masayuki
    INDUSTRIAL HEALTH, 2011, 49 (03) : 338 - 343
  • [44] Advantages of dynamic reaction cell ICP-MS for geological analyses
    Neubauer, Kenneth
    Beres, Steven
    Dionne, Luc
    Green, Damon
    Plasma Source Mass Spectrometry: Current Trends and Future Developments, 2005, (301): : 111 - 119
  • [45] Ultratrace and isotope ratios analyses of some radionuclides by ICP-MS
    Helal, AI
    Zahran, NF
    Amr, MA
    El-Lateef, AMA
    Bashter, II
    Mohsen, HT
    Abbas, Y
    RADIOCHIMICA ACTA, 2004, 92 (4-6) : 369 - 374
  • [46] Detection of transferrin isoforms in human serum:: comparison of UV and ICP-MS detection after CZE and HPLC separations
    Rodríguez, SA
    González, EB
    Llamas, GA
    Montes-Bayón, M
    Sanz-Medel, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (03) : 390 - 397
  • [47] Measurement uncertainty evaluation from correlated validation data: Determination of elemental impurities in pharmaceutical products by ICP-MS
    Milde, David
    Pluhacek, Tomas
    Kuba, Martin
    Souckova, Jitka
    Bettencourt da Silva, Ricardo J. N.
    TALANTA, 2020, 220
  • [48] Simple and reliable determination of total arsenic and its species in seafood by ICP-MS and HPLC-ICP-MS
    Nawrocka, Agnieszka
    Durkalec, Maciej
    Michalski, Miroslaw
    Posyniak, Andrzej
    FOOD CHEMISTRY, 2022, 379
  • [49] Strategies to overcome spectral interference in ICP-MS detection
    Lum, Tsz-Shan
    Leung, Kelvin Sze-Yin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (05) : 1078 - 1088
  • [50] Photochemical vapor generation of iodine for detection by ICP-MS
    Grinberg, Patricia
    Sturgeon, Ralph E.
    Journal of Analytical Atomic Spectrometry, 2009, 24 (04): : 508 - 514