Does Performance-Related Information Augment the Maximal Isometric Force in the Elbow Flexors?

被引:5
|
作者
Miller, William [1 ]
Jeon, Sunggun [1 ,4 ]
Kang, Minsoo [2 ]
Song, Jun Seob [1 ,3 ]
Ye, Xin [1 ,5 ]
机构
[1] Univ Mississippi, Neuromuscular Lab, Dept Hlth Exercise Sci & Recreat Management, 243A Turner Ctr Univ, University, MS 38677 USA
[2] Univ Mississippi, Hlth & Sport Analyt Lab, University, MS 38677 USA
[3] Univ Mississippi, Kevser Ermin Appl Physiol Lab, University, MS 38677 USA
[4] Oklahoma State Univ, Appl Neuromuscular Physiol Lab, Dept Hlth & Human Performance, Sch Kinesiol Appl Hlth & Recreat, Stillwater, OK 74078 USA
[5] Univ Hartford, Dept Rehabil Sci, Hartford, CT 06117 USA
关键词
Visual feedback; Verbal encouragement; Maximal voluntary isometric muscle action; Upper extremity; VERBAL ENCOURAGEMENT; NEUROMUSCULAR PERFORMANCE; VISUAL FEEDBACK; PEAK TORQUE; MUSCLE; STRENGTH; BIOFEEDBACK; INSTRUCTIONS; KNOWLEDGE; MALES;
D O I
10.1007/s10484-020-09492-x
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
The effects of different feedback conditions on the elbow flexors maximal voluntary isometric (MVIC) force were examined. In a single visit, twenty participants (10 males) were exposed to four conditions including, Visual only; (i.e., knowledge of results [VI]); Verbal encouragement (i.e., verbally stating pull, pull [VE]); VI and VE (VIVE); and no VI or VE (NOVIVE). Three, 5-s MVIC trials were completed for each condition. Separate 2 x 4 (sex x condition) repeated measures analyses of variance (ANOVA) were used to examine MVIC force, rate of force development (RFD200), and rate of electromyography (EMG) rise (RER200) for the 0-200-ms window. There was a significant main condition effect for MVIC force (p < 0.001). Significantly greater MVIC force was shown for VIVE compared to VE (p < 0.001) and NOVIVE (p = 0.002) conditions, and VI compared to VE (p = 0.011) and NOVIVE (p = 0.009) conditions. A significant sex x condition interaction (p = 0.036) was observed for RFD200, with significantly (p = 0.003) greater RFD200 in males compared to females, in the VI condition only. There were no significant differences in RFD200 among condition for males (p = 0.033) or females (p = 0.194). There was a significant main effect for sex (p = 0.006) for RER200, with significantly greater (p = 0.003) RER200 (conditions merged) in males (mean +/- standard deviation (SD): 422.99 +/- 124.67%), compared to females (220.68 +/- 134.01%). Here we suggest the importance of providing VI feedback alone, or in conjunction with VE, for the measurement of elbow flexion MVIC. Additionally, these results provide a foundational framework for future studies aiming to improve feedback modalities during training or rehabilitation.
引用
收藏
页码:91 / 101
页数:11
相关论文
共 50 条
  • [21] MAXIMAL ISOMETRIC FORCE AND NEURAL ACTIVITY DURING BILATERAL AND UNILATERAL ELBOW FLEXION IN HUMANS
    ODA, S
    MORITANI, T
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1994, 69 (03): : 240 - 243
  • [22] Fluctuations of isometric force after eccentric exercise of the elbow flexors of young, middle-aged, and old men
    Andrew P. Lavender
    Kazunori Nosaka
    European Journal of Applied Physiology, 2007, 100 : 161 - 167
  • [23] Fluctuations of isometric force after eccentric exercise of the elbow flexors of young, middle-aged, and old men
    Lavender, Andrew P.
    Nosaka, Kazunori
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2007, 100 (02) : 161 - 167
  • [24] Chronic hypoxia does not affect surface EMG and mechanomyographic signals during sustained isometric contractions of the elbow flexors
    Esposito, F
    Orizio, C
    Veicsteinas, A
    FASEB JOURNAL, 2003, 17 (04): : A36 - A36
  • [25] Does the Length of Elbow Flexors and Visual Feedback Have Effect on Accuracy of Isometric Muscle Contraction in Men after Stroke?
    Juodzbaliene, Vilma
    Darbutas, Tomas
    Skurvydas, Albertas
    Brazaitis, Marius
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [26] EFFECTS OF TWO DIFFERENT SELF-ADAPTED OCCLUSAL SPLINTS ON ELECTROMYOGRAPHIC AND FORCE PARAMETERS DURING ELBOW FLEXORS ISOMETRIC CONTRACTION
    Limonta, Eloisa
    Arienti, Chiara
    Rampichini, Susanna
    Venturelli, Massimo
    Ce, Emiliano
    Veicsteinas, Arsenio
    Esposito, Fabio
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2018, 32 (01) : 230 - 236
  • [27] Submaximal isometric fatiguing exercise of the elbow flexors has no age-related effect on GABAB-mediated inhibition
    Otieno, Lavender A.
    Semmler, John G.
    Smith, Ashleigh E.
    Sidhu, Simranjit K.
    JOURNAL OF APPLIED PHYSIOLOGY, 2022, 132 (01) : 167 - 177
  • [28] Maximal voluntary isometric elbow flexion force during unilateral versus bilateral contractions in individuals with chronic stroke
    McQuade, Kevin
    Harris-Love, Michelle L.
    Whitall, Jill
    JOURNAL OF APPLIED BIOMECHANICS, 2008, 24 (01) : 69 - 74
  • [29] Differences between young and older women in maximal force, force fluctuations, and surface EMG during isometric knee extension and elbow flexion
    Bazzucchi, I
    Felici, F
    Macaluso, A
    De Vito, G
    MUSCLE & NERVE, 2004, 30 (05) : 626 - 635
  • [30] Are There Differences Between Sexes in Performance-Related Variables During a Maximal Intermittent Flywheel Test?
    Salse-Batan, Jorge
    Torrado, Priscila
    Marina, Michel
    SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2025,