Four-dimensional patient-specific musculoskeletal model of the patient after Total Hip Arthroplasty

被引:4
|
作者
Otake, Y [1 ]
Suzuki, N [1 ]
Hattori, A [1 ]
Miki, H [1 ]
Yamamura, M [1 ]
Nakamura, N [1 ]
Sugano, N [1 ]
Yonenobu, K [1 ]
Ochi, T [1 ]
机构
[1] Jikei Univ, Sch Med, Inst High Dimens Med Imaging, Komae, Tokyo 2018601, Japan
关键词
four-dimensional motion analysis; muscle model; total hip arthroplasty;
D O I
10.1016/j.ics.2004.03.207
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We constructed a four-dimensional (4D) patient-specific musculoskeletal model of the patient having had Total Hip Arthroplasty (THA). The model includes the three-dimensional skeletal structures, the muscles and the movement data from optical motion capture system. This model reflects the patient-specific characteristics of the bone geometry, implant alignment and the characteristics of the movement. The muscle model proposed in this paper is the string-typed model representing the route of the muscles. The strings expands and contracts according to the movement of the origin and insertion location of the muscle and we can estimate the direction of the muscle force and the length of the muscles. We developed models of the seven muscles and muscle groups related to the movement of the hip joint. By using this model, clinicians can predict the potential for dislocation or recognize the causes of dislocation, including the influence of the muscles. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:591 / 596
页数:6
相关论文
共 50 条
  • [21] Patient-specific approach in total knee arthroplasty
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Adams, Joanne B.
    ORTHOPEDICS, 2008, 31 (09) : 927 - 930
  • [22] Patient-specific instrumentation in total knee arthroplasty
    Mathis, Dominic T.
    Hirschmann, Michael T.
    ARTHROSKOPIE, 2021, 34 (05) : 342 - 350
  • [23] Patient-specific instruments in total knee arthroplasty
    Conteduca, Fabio
    Iorio, Raffaele
    Mazza, Daniele
    Ferretti, Andrea
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) : 259 - 265
  • [24] Patient-specific instruments in total knee arthroplasty
    Fabio Conteduca
    Raffaele Iorio
    Daniele Mazza
    Andrea Ferretti
    International Orthopaedics, 2014, 38 : 259 - 265
  • [25] The effect of range of motion simulated with a patient-specific three-dimensional simulation analysis on dislocation after total hip arthroplasty
    Mitsutake, Ryo
    Tanino, Hiromasa
    Ito, Hiroshi
    HIP INTERNATIONAL, 2023, 33 (02) : 313 - 322
  • [26] Patient-specific instrumentation for total shoulder arthroplasty
    Gomes, Nuno Sampaio
    EFORT OPEN REVIEWS, 2016, 1 (05): : 177 - 182
  • [27] A Comparative Study of Patients' Subjective Feelings Toward Total Hip Arthroplasty with Patient-Specific Instruments and Traditional Total Hip Arthroplasty
    Xing, Qi-qi
    Zhong, Da
    Pan, Yi-xiao
    An, Sen-bo
    Wang, Cheng-gong
    Su, Shi-long
    Wang, Long
    Hu, Yi-he
    ORTHOPAEDIC SURGERY, 2020, 12 (01) : 269 - 276
  • [28] A Geometric Model to Determine Patient-Specific Cup Anteversion Based on Pelvic Motion in Total Hip Arthroplasty
    Sutter, E. Grant
    Wellman, Samuel S.
    Bolognesi, Michael P.
    Seyler, Thorsten M.
    ADVANCES IN ORTHOPEDICS, 2019, 2019
  • [29] Four-Dimensional Determination of the Patient-Specific Centre of Rotation for Total Temporomandibular Joint Replacements: Following the Groningen Principle
    Merema, Bram B. J.
    Witjes, Max J. H.
    Van Bakelen, Nicolaas B.
    Kraeima, Joep
    Spijkervet, Frederik K. L.
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (09):
  • [30] Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty
    Spencer-Gardner, L.
    Pierrepont, J.
    Topham, M.
    Bare, J.
    McMahon, S.
    Shimmin, A. J.
    BONE & JOINT JOURNAL, 2016, 98B (10): : 1342 - 1346