The coupling of LC to ICP-MS in element speciation - Part II: Recent trends in application

被引:54
|
作者
Michalke, B [1 ]
机构
[1] GSF, Natl Res Ctr Environm & Hlth, Inst Ecol Chem, D-85764 Neuherberg, Germany
关键词
liquid chromatography; inductively coupled plasma-mass spectrometry; speciation;
D O I
10.1016/S0165-9936(02)00303-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This two-part article covers the application of liquid chromatography (LC) combined with inductively coupled plasma-mass spectrometry (ICP-MS) in the field of speciation. In this second part, the focus is on some "key elements" in speciation as well as the most popular elements for speciation. As examples, it describes some recent publications on As-, Se- and Cd-speciation, including investigations on metal-lothioneins, as well as iodine-speciation and Pt-speciation. Tin-speciation is still dominated by GC-AED, but has recently become of interest in LC-ICP-NIS hyphenations. (C) 2002 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:154 / 165
页数:12
相关论文
共 50 条
  • [31] Arsenic speciation: HPLC followed by ICP-MS or INAA
    W. D. James
    T. Raghvan
    T. J. Gentry
    G. Shan
    R. H. Loeppert
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 267 - 270
  • [32] Multielement trace-element speciation in metal- biomolecules by chromatography coupled with ICP-MS
    Ferrarello, CN
    de la Campa, MRF
    Sanz-Medel, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) : 412 - 421
  • [33] ICP-AES and ICP-MS: Trends and Pittcon'98
    Pecheyran, C
    ANALUSIS, 1998, 26 (04) : M88 - M91
  • [34] The application and development of elemental speciation analysis in foods by ICP-MS related hyphenated technique
    Zu, Wen-Chuan
    Wang, Yu
    Li, Bing-Ning
    Ren, Min
    Liu, Cong
    Wu, Yan-Wen
    Chen, Shun-Cong
    Journal of Chinese Mass Spectrometry Society, 2013, 34 (04) : 247 - 256
  • [35] ICP-MS trace element analysis of steels
    Kuss, HM
    NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1995, 43 (7-8): : 804 - +
  • [36] Trace element determination in lichens by ICP-MS
    Bettinelli, M
    Spezia, S
    Bizzarri, G
    ATOMIC SPECTROSCOPY, 1996, 17 (03) : 133 - 141
  • [37] Application of ICP-MS in environmental science
    Prohaska, T
    Köllensperger, G
    Hann, S
    Stingeder, G
    Fitz, W
    Wenzel, W
    PLASMA SOURCE MASS SPECTROMETRY: APPLICATIONS AND EMERGING TECHNOLOGIES, 2003, : 93 - 104
  • [38] Application and quality of ICP-MS analysis
    Prohaska, T
    Stingeder, G
    Nelms, SM
    Quétel, C
    Latkoczy, C
    Hann, S
    Köllensperger, G
    Taylor, P
    PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267): : 165 - 176
  • [39] Interface development for coupling capillary electrophoresis (CE) and inductively coupled plasma - Mass spectrometry (ICP-MS): Application to plutonium speciation
    Baglan, N
    Delorme, A
    Aupiais, J
    PLUTONIUM FUTURES - THE SCIENCE, 2003, 673 : 393 - 395
  • [40] Impact of Measurement Protocol on ICP-MS Data Quality Objectives: Part II
    Thomas, Robert (SpectroscopyEdit@mmhgroup.com), 1600, Advanstar Communications Inc. (36):