Fully Integrated Biopotential Acquisition Analog Front-End IC

被引:22
|
作者
Song, Haryong [1 ]
Park, Yunjong [1 ]
Kim, Hyungseup [1 ]
Ko, Hyoungho [1 ]
机构
[1] Chungnam Natl Univ, Dept Elect, Taejon 305764, South Korea
基金
新加坡国家研究基金会;
关键词
biopotential; capacitively-coupled chopper instrumentation amplifier (CCIA); DC servo loop (DSL); ripple reduction loop (RRL); capacitive input boosting loop (CIBL); INSTRUMENTATION AMPLIFIER; SYSTEMS; CMOS;
D O I
10.3390/s151025139
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biopotential acquisition analog front-end (AFE) integrated circuit (IC) is presented. The biopotential AFE includes a capacitively coupled chopper instrumentation amplifier (CCIA) to achieve low input referred noise (IRN) and to block unwanted DC potential signals. A DC servo loop (DSL) is designed to minimize the offset voltage in the chopper amplifier and low frequency respiration artifacts. An AC coupled ripple rejection loop (RRL) is employed to reduce ripple due to chopper stabilization. A capacitive impedance boosting loop (CIBL) is designed to enhance the input impedance and common mode rejection ratio (CMRR) without additional power consumption, even under an external electrode mismatch. The AFE IC consists of two-stage CCIA that include three compensation loops (DSL, RRL, and CIBL) at each CCIA stage. The biopotential AFE is fabricated using a 0.18 mu m one polysilicon and six metal layers (1P6M) complementary metal oxide semiconductor (CMOS) process. The core chip size of the AFE without input/output (I/O) pads is 10.5 mm(2). A fourth-order band-pass filter (BPF) with a pass-band in the band-width from 1 Hz to 100 Hz was integrated to attenuate unwanted signal and noise. The overall gain and band-width are reconfigurable by using programmable capacitors. The IRN is measured to be 0.94 mu V-RMS in the pass band. The maximum amplifying gain of the pass-band was measured as 71.9 dB. The CIBL enhances the CMRR from 57.9 dB to 67 dB at 60 Hz under electrode mismatch conditions.
引用
收藏
页码:25139 / 25156
页数:18
相关论文
共 50 条
  • [41] A 40 Gbit/s fully integrated optical receiver analog front-end in 90 nm CMOS
    XU ZhigangCHEN YingmeiWANG TaoCHEN XuehuiZHANG Li Institute of RF OEICsSoutheast UniversityNanjing China
    The Journal of China Universities of Posts and Telecommunications, 2012, 19 (01) : 124 - 128
  • [42] MEMS DISK RESONATOR GYROSCOPE WITH INTEGRATED ANALOG FRONT-END
    Su, T. -H.
    Nitzan, S.
    Taheri-Tehrani, P.
    Kline, M.
    Boser, B.
    Horsley, D. A.
    2013 IEEE SENSORS, 2013, : 163 - 166
  • [43] A 40 Gbit/s fully integrated optical receiver analog front-end in 90 nm CMOS
    Xu, Zhi-Gang
    Chen, Ying-Mei
    Wang, Tao
    Chen, Xue-Hui
    Zhang, Li
    Journal of China Universities of Posts and Telecommunications, 2012, 19 (01): : 124 - 128
  • [44] A fully integrated analog front-end macro for cable modem applications in 0.18-μm CMOS
    Wiesbauer, A
    Clara, M
    Harteneck, M
    Pötscher, T
    Seger, B
    Sandner, C
    Fleischhacker, C
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2002, 37 (07) : 866 - 873
  • [45] A highly integrated analog front-end for 3G
    Khalil, W
    Chang, TY
    Jiang, XW
    Naqvi, SR
    Nikjou, B
    Tseng, J
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (05) : 774 - 781
  • [46] High-CMRR Low-Noise Fully Integrated Front-End for EEG Acquisition Systems
    Chebli, Robert
    Ali, Mohamed
    Sawan, Mohamad
    ELECTRONICS, 2019, 8 (10)
  • [47] Chopper Stabilized Analog Front-End IC with Improved Ripple Reduction Loop
    Park, Yunjong
    Song, Haryong
    Kim, Hyungsup
    Ko, Hyoungho
    2015 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2015, : 229 - 230
  • [48] A CMOS analog front-end IC for portable EEG/ECG monitoring applications
    Ng, KA
    Chan, PK
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2005, 52 (11) : 2335 - 2347
  • [49] A Programmable Analog Front-End IC Applied for Biomedical Signal Monitoring Systems
    Yushi Chen
    Hualian Tang
    Zhiyuan Wang
    Peng Xu
    Yiqi Zhuang
    Circuits, Systems, and Signal Processing, 2023, 42 : 2 - 26
  • [50] The analog front-end section of the BaBar silicon vertex tracker readout IC
    Manfredi, PF
    Kipnis, I
    Leona, A
    Luo, L
    Mandelli, E
    Momayezi, M
    Nyman, M
    Pedrali-Noy, M
    Re, V
    Roe, N
    Svelto, F
    NUCLEAR PHYSICS B, 1998, : 532 - 538