Limited-angle tomography for analyzer-based phase-contrast x-ray imaging

被引:1
|
作者
Majidi, Keivan [1 ]
Wernick, Miles N. [1 ]
Li, Jun [2 ]
Muehleman, Carol [2 ]
Brankov, Jovan G. [1 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] Rush Univ, Med Ctr, Dept Biochem, Chicago, IL 60612 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 13期
关键词
x-ray; phase contrast; tomosynthesis; limited angle tomography; COMPUTED-TOMOGRAPHY; BREAST-CANCER; RADIOGRAPHY; REFRACTION; CT; RECONSTRUCTION; IMPLEMENTATION; IMAGES;
D O I
10.1088/0031-9155/59/13/3483
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
引用
收藏
页码:3483 / 3500
页数:18
相关论文
共 50 条
  • [31] Modeling the phase-contrast X-ray tomography imaging of medical samples
    S. V. Gasilov
    I. V. Gasilova
    S. V. Dyachenko
    Mathematical Models and Computer Simulations, 2012, 4 (6) : 560 - 567
  • [32] Phase-contrast x-ray imaging and tomography of the nematode Caenorhabditis elegans
    Olendrowitz, C.
    Bartels, M.
    Krenkel, M.
    Beerlink, A.
    Mokso, R.
    Sprung, M.
    Salditt, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (16):
  • [33] Optimal contrast for X-ray phase-contrast imaging
    College of Medical Instrument, University of Shanghai Science and Technology, Shanghai 200093, China
    不详
    Guangzi Xuebao, 2008, 6 (1217-1220):
  • [34] On analyzing of the contrast for X-ray phase-contrast imaging
    Liu, S.
    Zhang, X. L.
    Huang, Y.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1168 - 1171
  • [35] Biases of estimated signals in x-ray analyzer-based imaging
    夏健霖
    徐文
    周瑞成
    石晓敏
    任坤
    陈恒
    王志立
    Chinese Physics B, 2020, 29 (06) : 666 - 671
  • [36] A Multiscale Reconstruction Framework Based on Edge-Enhanced Guidance for In-Line X-Ray Phase-Contrast CT With Limited-Angle Projections
    Li, Yimin
    Zhao, Yuanyuan
    Ma, Chenyang
    Li, Fangzhi
    Wang, Ziyao
    Lv, Wenjuan
    Ji, Dongjiang
    Jian, Jianbo
    Zhao, Xinyan
    Zhao, Yuqing
    Hu, Chunhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [37] Hard X-ray phase-contrast imaging
    Gao, D.C.
    Pogany, A.
    Stevenson, A.W.
    Gureyev, T.
    Wilkins, S.W.
    Mai, Zhen-Hong
    Wuli Xuebao/Acta Physica Sinica, 2000, 49 (12): : 2367 - 2368
  • [38] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [39] Benchtop phase-contrast X-ray imaging
    Gundogdu, O.
    Nirgianaki, E.
    Ismail, E. Che
    Jenneson, P. M.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (12) : 1337 - 1344
  • [40] Hard X-ray phase-contrast imaging
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    Mai, ZH
    ACTA PHYSICA SINICA, 2000, 49 (12) : 2357 - 2368