Real-time beam monitoring in scanned proton therapy

被引:5
|
作者
Klimpki, G. [1 ]
Eichin, M. [1 ]
Bula, C. [1 ]
Rechsteiner, U. [1 ]
Psoroulas, S. [1 ]
Weber, D. C. [1 ,2 ]
Lomax, A. [1 ]
Meer, D. [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, CH-5232 Villigen, Switzerland
[2] Univ Hosp Zurich, Dept Radiat Oncol, Ramistr 100, CH-8091 Zurich, Switzerland
关键词
Beam monitoring; Real-time controls; Particle beam scanning; Proton therapy; Patient safety; SYSTEM; FACILITY; DESIGN; PSI;
D O I
10.1016/j.nima.2018.02.107
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
When treating cancerous tissues with protons beams, many centers make use of a step-and-shoot irradiation technique, in which the beam is steered to discrete grid points in the tumor volume. For safety reasons, the irradiation is supervised by an independent monitoring system validating cyclically that the correct amount of protons has been delivered to the correct position in the patient. Whenever unacceptable inaccuracies are detected, the irradiation can be interrupted to reinforce a high degree of radiation protection. At the Paul Scherrer Institute, we plan to irradiate tumors continuously. By giving up the idea of discrete grid points, we aim to be faster and more flexible in the irradiation. But the increase in speed and dynamics necessitates a highly responsive monitoring system to guarantee the same level of patient safety as for conventional step-and-shoot irradiations. Hence, we developed and implemented real-time monitoring of the proton beam current and position. As such, we read out diagnostic devices with 100 kHz and compare their signals against safety tolerances in an FPGA. In this paper, we report on necessary software and firmware enhancements of our control system and test their functionality based on three exemplary error scenarios. We demonstrate successful implementation of real-time beam monitoring and, consequently, compliance with international patient safety regulations.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 50 条
  • [41] Intensity-modulated proton therapy with a scanned beam: Study of the effects of the beam instability
    Trofimov, A
    Slopsema, R
    Bortfeld, T
    Kooy, H
    Flanz, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1797 - 1798
  • [42] Patient Treatment Quality Assurance for a Uniformly Scanned Proton Therapy Beam
    Baillie, N.
    Lee, T.
    Duvvuri, S.
    Shahnazi, K.
    Athar, B.
    Long, C.
    Butuceanu, C.
    Nazaryan, V.
    Keppel, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3538 - 3539
  • [43] Impact of spot size variations on dose in scanned proton beam therapy
    Kraan, A. C.
    Depauw, N.
    Clasie, B.
    Madden, T.
    Kooy, H. M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 58 - 64
  • [45] A real-time phase-space beam emittance monitoring system
    Samadi, Nazanin
    Shi, Xianbo
    Dallin, Les
    Chapman, Dean
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1213 - 1219
  • [46] In situ real-time beam monitoring with dielectric meta-holograms
    Blau, Yoav
    Eitan, Michal
    Egorov, Victor
    Boag, Amir
    Hanein, Yael
    Scheuer, Jacob
    OPTICS EXPRESS, 2018, 26 (22): : 28469 - 28483
  • [47] Real-time beam loss monitoring system and its applications in SRRC
    Hsu, KT
    Lin, KK
    Kuo, CH
    Liu, YC
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2259 - 2261
  • [48] A real-time beam loss monitoring system for storage ring of SSRF
    Cai Jun
    Xu Xunjiang
    Xia Xiaobin
    Hou Lei
    Zeng Ming
    Wang Jianhua
    Wang Guanghong
    Liu Xin
    Xu Jiaqiang
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (01) : 5 - 8
  • [49] Real-Time Verification of VMAT Delivery by An Automated Beam Monitoring System
    Farrokhkish, M.
    Islam, M.
    Heaton, R.
    Norrlinger, B.
    Jaffray, D.
    MEDICAL PHYSICS, 2017, 44 (06) : 2879 - 2879
  • [50] In situ Real-Time Beam Monitoring with Dielectric Meta-Holograms
    Blau, Yoav
    Eitan, Michal
    Egorov, Victor
    Boag, Amir
    Hanein, Yael
    Scheuer, Jacob
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,