Study of single perfobond rib with head stud shear connectors for a composite structure

被引:8
|
作者
Deng, Wenqin [1 ]
Gu, Jiancheng [2 ]
Liu, Duo [3 ]
Hu, Jun [1 ]
Zhang, Jiandong [1 ,2 ,3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Civil Engn & Mech, Wuhan, Hubei, Peoples R China
[2] Nanjing Univ Technol, Coll Civil Engn, Nanjing, Jiangsu, Peoples R China
[3] Jiangsu Transportat Res Inst, Nanjing, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
composite materials; joints; shear; STRENGTH; BEHAVIOR;
D O I
10.1680/jmacr.18.00051
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The head stud connector and the perfobond rib connector are the most common forms of ductile and rigid shear connector, respectively, but have strengths and weaknesses. This study evaluates the behaviour of a single perfobond rib with head stud shear connector that combines the advantages of both. First, a shear resistance equation is proposed to predict the strength of the single perfobond rib with head stud shear connector based on equations for the head stud connector and the single perfobond rib shear connector. Five groups of single perfobond rib with head stud shear connectors, ten push-out test specimens in total, were used to investigate the fracture failure mode, load-slip relationship, shear capacity and ductility of the specimens. Based on the test results, the influences of the parameters of the shear connector on shear capacity are discussed. The experiments show that the single perfobond rib with head stud shear connector is superior in terms of shear resistance and ductility. Shear capacity and corresponding relative slip of the specimens increase with increasing diameter of the head stud and transverse rebar, whereas ductility decreases. The accuracy of the proposed shear-capacity equation is verified by comparison with the test results.
引用
收藏
页码:920 / 934
页数:15
相关论文
共 50 条
  • [41] Shear behavior and analytical model of T-type perfobond rib connectors
    Zhan, Yulin
    Huang, Wenfeng
    Li, Yanyan
    Zhang, Cheng
    Shao, Junhu
    Tian, Bo
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2023, 23 (03)
  • [42] Effect of rebar strength in Y-type perfobond rib shear connectors
    Kim, S. H.
    Han, O.
    Kim, K. S.
    Kim, S. J.
    Shin, J. Y.
    MAINTENANCE, SAFETY, RISK, MANAGEMENT AND LIFE-CYCLE PERFORMANCE OF BRIDGES, 2018, : 381 - 385
  • [43] Shear Performance Study of Sleeved Stud Connectors in Continuous Composite Girder
    Wu, Fei
    Su, Hang
    Su, Qingtian
    Yuan, Bo
    MATERIALS, 2024, 17 (13)
  • [44] Experimental and numerical investigations on the flexural behavior of steel-uhpc composite slabs with perfobond rib shear connectors
    Zhou M.
    Xiao J.-L.
    Yang T.-Y.
    Nie J.-G.
    Fan J.-S.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (07): : 19 - 29
  • [45] Experimental Study on the Mechanical Properties of Perfobond Rib Shear Connectors with Steel Fiber High Strength Concrete
    Wu, Fangwen
    Liu, Shuo
    Xue, Chengfeng
    Yang, Kangkang
    Feng, Yanpeng
    Zhang, Hao
    MATERIALS, 2021, 14 (12)
  • [46] Behavior of headed stud shear connectors in composite beam
    Lam, D
    El-Lobody, E
    JOURNAL OF STRUCTURAL ENGINEERING, 2005, 131 (01) : 96 - 107
  • [47] Experimental and Numerical Evaluation of Perfobond Rib Shear Connectors Embedded in Recycled Aggregate Concrete
    Yu, Zhenxuan
    He, Shaohua
    Mosallam, Ayman S.
    Jiang, Shuo
    Feng, Wenxian
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [48] Rib shear connectors in composite profiled slabs
    Burnet, MJ
    Oehlers, DJ
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (12) : 1267 - 1287
  • [49] Experimental study on behavior of π-type perfobond shear connectors
    Li G.
    Wang Z.
    Yang Z.
    Xu W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (02): : 131 - 141
  • [50] Push-out tests and evaluation of FRP perfobond rib shear connectors performance
    Kolpasky, Ludvik
    Ryjacek, Pavel
    BUILDING UP EFFICIENT AND SUSTAINABLE TRANSPORT INFRASTRUCTURE 2017 (BESTINFRA2017), 2017, 236