Analysis of human hippocampus gangliosides by fully-automated chip-based nanoelectrospray tandem mass spectrometry

被引:44
|
作者
Vukelic, Zeljka
Zarei, Mostafa
Peter-Katalinic, Jasna
Zamfir, Alina D. [1 ]
机构
[1] Univ Munster, Inst Med Phys & Biophys, Munster, Germany
[2] Univ Zagreb, Fac Med, Dept Chem & Biochem, Zagreb 41000, Croatia
[3] Natl Inst Res & Dev Electrochem & Condensed Matte, Timisoara, Romania
关键词
microfluidics; electrospray ionization; gangliosides; hippocampus;
D O I
10.1016/j.chroma.2006.05.033
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Modem microfluidic devices are currently introduced in electrospray (ESI) mass spectrometry (MS), tending to substitute the classical capillary-based ESI infusion. Automated systems using the combination of robotized sample handling and chip-based ESI are significantly increasing the analysis reproducibility, precision, throughput, and efficiency. In the last couple of years our group developed the chip-based ESI-MS approach for glycomics in biomedical research and applied it for oligosaccharide, glycopeptide and ganglioside investigation. Here we report upon the optimization and application of this modem technique for the analysis of differential ganglioside expression patterns in human fetal and adult hippocampus. By this methodology, ganglioside species exhibiting high degree of heterogeneity in the ceramide motifs and biologically-relevant modifications could be identified in human hippocampus. The ultra-high reproducibility of the experiments uniquely provided by the chip-ESI approach allowed for a reliable MS-based ganglioside comparative assay. Moreover, the particular feature of chip ESI-tandem MS to provide structural information at high sensitivity was useful for detailed characterization of hippocampus-associated species. The experimental data presented in this study indicate the benefits of microfluidic/MS for determination of the topospecific brain ganglioside composition and development-related changes in their expression, which might be of high Value in clinical investigation and for studies related to ganglioside-based therapy of central nervous system diseases. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:238 / 245
页数:8
相关论文
共 50 条
  • [41] A micromachined chip-based electrospray source for mass spectrometry
    Licklider, L
    Wang, XQ
    Desai, A
    Tai, YC
    Lee, TD
    ANALYTICAL CHEMISTRY, 2000, 72 (02) : 367 - 375
  • [42] Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine
    Deng, YZ
    Henion, J
    Li, JJ
    Thibault, P
    Wang, C
    Harrison, DJ
    ANALYTICAL CHEMISTRY, 2001, 73 (03) : 639 - 646
  • [43] Chip-based separation devices coupled to mass spectrometry
    Ohla, Stefan
    Belder, Detlev
    CURRENT OPINION IN CHEMICAL BIOLOGY, 2012, 16 (3-4) : 453 - 459
  • [44] Automated chip-nanoelectrospray mass spectrometry for glycourinomics in Schindler disease type I
    Sarbu, Mirela
    Robu, Adrian
    Peter-Katalinic, Jasna
    Zamfir, Alina D.
    CARBOHYDRATE RESEARCH, 2014, 398 : 90 - 100
  • [45] Negative ion 'chip-based' nanospray tandem mass spectrometry for the analysis of flavonoids in glandular trichomes of Lychnophora ericoides Mart
    Gobbo-Neto, L.
    Gates, P. J.
    Lopes, N. P.
    PLANTA MEDICA, 2008, 74 (09) : 920 - 920
  • [46] Novel Stable Isotope-Resolved Metabolomics Method for a Small Number of Cells Using Chip-Based Nanoelectrospray Mass Spectrometry
    Yu, Di
    Zheng, Fujian
    Wang, Lichao
    Li, Chao
    Lu, Xin
    Lin, Xiaohui
    Zhou, Lina
    Xu, Guowang
    ANALYTICAL CHEMISTRY, 2021, 93 (41) : 13765 - 13773
  • [47] Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma
    Deng, YZ
    Zhang, NW
    Henion, J
    ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1432 - 1439
  • [48] Chip-based nano-liquid chromatography-electrospray-tandem mass spectrometry analysis of 7-aminoflunitrazepam in urine
    Fuh, Ming-Ren
    Bai, Hsin-Yu
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [49] Coupling of fully automated chip-based electrospray ionization to high-capacity ion trap mass spectrometer for ganglioside analysis
    Almeida, Reinaldo
    Mosoarca, Cristina
    Chirita, Marius
    Udrescu, Valentina
    Dinca, Nicolae
    Vukelic, Zeljka
    Allen, Mark
    Zamfir, Alina D.
    ANALYTICAL BIOCHEMISTRY, 2008, 378 (01) : 43 - 52
  • [50] Nano-LC fraction analysis by chip-based nanoelectrospray for improved glycopeptide characterization
    Corso, T.
    Van Pelt, C.
    Huang, X.
    Li, J.
    MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S300 - S300