Cross-Sectional Changes in Lung Volume Measured by Electrical Impedance Tomography Are Representative for the Whole Lung in Ventilated Preterm Infants

被引:46
|
作者
van der Burg, Pauline S. [1 ]
Miedema, Martijn [1 ]
de Jongh, Frans H. [1 ]
Frerichs, Inez [2 ]
van Kaam, Anton H. [1 ]
机构
[1] Emma Childrens Hosp, Acad Med Ctr, Dept Neonatol, Amsterdam, Netherlands
[2] Univ Med Ctr Schleswig Holstein, Dept Anesthesiol & Intens Care Med, Kiel, Germany
关键词
electrical impedance tomography; high-frequency oscillatory ventilation; premature infant; recruitment; respiratory distress syndrome; respiratory inductive plethysmography; RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY; POSITIVE AIRWAY PRESSURE; FREQUENCY OSCILLATORY VENTILATION; BIRTH-WEIGHT INFANTS; PREMATURE-INFANTS; BREATHING PATTERN; PEEP; RECRUITMENT; ANESTHESIA; ACCURACY;
D O I
10.1097/CCM.0000000000000230
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Electrical impedance tomography measures lung volume in a cross-sectional slice of the lung. Whether these cross-sectional volume changes are representative of the whole lung has only been investigated in adults, showing conflicting results. This study aimed to compare cross-sectional and whole lung volume changes using electrical impedance tomography and respiratory inductive plethysmography. Design: A prospective, single-center, observational, nonrandomized study. Setting: The study was conducted in a neonatal ICU in the Netherlands. Patients: High-frequency ventilated preterm infants with respiratory distress syndrome. Interventions: Cross-sectional and whole lung volume changes were continuously and simultaneously measured by, respectively, electrical impedance tomography and respiratory inductive plethysmography during a stepwise recruitment procedure. End-expiratory lung volume changes were assessed by mapping the inflation and deflation limbs using both the pressure/impedance and pressure/inductance pairs and characterized by calculating the inflection points. In addition, oscillatory tidal volume changes were assessed at each pressure step. Measurements and Main Results: Twenty-three infants were included in the study. Of these, eight infants had to be excluded because the quality of the registration was insufficient for analysis (two electrical impedance tomography and six respiratory inductive plethysmography). In the remaining 15 infants (gestational age 28.0 2.6 wk; birth weight 1,027 +/- 514 g), end-expiratory lung volume changes measured by electrical impedance tomography were significantly correlated to respiratory inductive plethysmography measurements in 12 patients (mean r = 0.93 +/- 0.05). This was also true for the upper inflection point on the inflation (r = 0.91, p < 0.01) and deflation limb (r = 0.83, p < 0.01). In 13 patients, impedance and inductance data also correlated significantly on oscillatory tidal volume/pressure relationships (mean r = 0.81 +/- 0.18). Conclusions: This study shows that cross-sectional lung volume changes measured by electrical impedance tomography are representative for the whole lung and that this concept also applies to newborn infants.
引用
收藏
页码:1524 / 1530
页数:7
相关论文
共 50 条
  • [41] Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury
    Kunst, PWA
    Böhm, SH
    de Anda, GV
    Amato, MBP
    Lachmann, B
    Postmus, PE
    de Vries, PMJM
    CRITICAL CARE MEDICINE, 2000, 28 (01) : 178 - 183
  • [42] Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution?
    Inéz Frerichs
    Peter A. Dargaville
    Taras Dudykevych
    Peter C. Rimensberger
    Intensive Care Medicine, 2003, 29 : 2312 - 2316
  • [43] Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography
    Markhorst, D.G.
    Groeneveld, A.B.J.
    Heethaar, R.M.
    Zonneveld, E.
    Van Genderingen, H.R.
    Journal of Medical Engineering and Technology, 2009, 33 (04): : 281 - 287
  • [44] Lung volume and cardiorespiratory changes during open and closed endotracheal suction in ventilated newborn infants
    Hoellering, A. B.
    Copnell, B.
    Dargaville, P. A.
    Mills, J. F.
    Morley, C. J.
    Tingay, D. G.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2008, 93 (06): : 1436 - 1441
  • [45] INITIAL EXPERIENCE WITH INTRAPROCEDURAL ELECTRICAL IMPEDANCE TOMOGRAPHY FOR EVALUATING REGIONAL VENTILATION CHANGES DURING BRONCHOSCOPIC LUNG VOLUME REDUCTION
    Swenson, Kai
    Munoz, Ricardo
    Azizi, Basit
    Suleiman, Aiman
    Parikh, Mihir
    Kassis, Elias Baedorf
    Majid, Adnan
    Schaefer, Maximilian
    CHEST, 2022, 162 (04) : 2121A - 2122A
  • [46] Regional pulmonary pressure volume curves in mechanically ventilated patients with acute respiratory failure measured by electrical impedance tomography
    Hinz, J
    Moerer, O
    Neumann, P
    Dudykevych, T
    Frerichs, I
    Hellige, G
    Quintel, M
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (03) : 331 - 339
  • [47] Chest x-ray findings versus lung volume as measured by the SF6 washout technique in ventilated preterm infants. † 1606
    Ulrich Thome
    Andreas Töpfer
    Peter Schaller
    Frank Pohlandt
    Pediatric Research, 1997, 41 (Suppl 4) : 270 - 270
  • [48] Effects of pleural effusion drainage in the mechanically ventilated patient as monitored by electrical impedance tomography and end-expiratory lung volume: A pilot study
    Rara, Ales
    Roubik, Karel
    Tyll, Tomas
    JOURNAL OF CRITICAL CARE, 2020, 59 : 76 - 80
  • [49] Ventilation and cardiac/perfusion related impedance changes of the lung determined by Electrical Impedance Tomography in cystic fibrosis
    Krueger-Ziolek, S.
    Schullcke, B.
    Gong, B.
    Mueller-Lisse, U.
    Moeller, K.
    IFAC PAPERSONLINE, 2017, 50 (01): : 9938 - 9942
  • [50] Congenital masses of the lung: Changes in cross-sectional area during gestation
    Winters, WD
    Effmann, EL
    Nghiem, HV
    Nyberg, DA
    JOURNAL OF CLINICAL ULTRASOUND, 1997, 25 (07) : 372 - 377