Silicon Mach-Zehnder interferometer racetrack microring for sensing

被引:2
|
作者
Xiong, Yule [1 ]
Ye, Winnie N. [1 ]
机构
[1] Carleton Univ, Dept Elect, Ottawa, ON K1S 5B6, Canada
来源
SILICON PHOTONICS IX | 2014年 / 8990卷
关键词
microring resonator; Mach-Zehnder interferometer; multimode interference; sensing; RING-RESONATOR;
D O I
10.1117/12.2037405
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
SOI-based microring resonators (MRRs) have attracted extensive attentions as ultra-compact sensors. Recently, a new structure design combining a ring and a Mach-Zehnder interferometer (MZI) was proposed as sensors for biomedical applications, and as modulators for communications applications. In this design, the MZI uses two identical couplers, where one arm is formed by connecting the access waveguide of the couplers, while the other arm is part of the microring. Such a device may have only one major resonance with a high extinction ratio in a very broad wavelength span (quasi-free spectral range, quasi-FSR), which offers a very large measurement range for sensing applications. 2x2 multimode interference (MMI) couplers are used to couple the microring and the bus waveguides as MMI couplers have broader wavelength responses. We present the first experimental demonstration of the MMI-coupled MZI racetrack microrings for sensing applications. Two types of MMI-coupled MZI racetrack microrings are discussed: one with wire waveguides, and the other using slotted waveguides. For the MZI racetrack microring using wire waveguides, we achieve a quasi-FSR of 34.3 nm near the wavelength of 1520 nm. The corresponding major resonance of the MZI racetrack microring demonstrates a high extinction ratio of similar to 22.4 dB with a full-width-half-maximum (FWHM) of 1.94 nm, and a quality factor Q of similar to 800. On the other hand, the quasi-FSR of the MZI racetrack microring with slot waveguides is 23.2 nm near the wavelength of 1540 nm; and the extinction ratio of the major resonance is similar to 24.5 dB with lambda(FWHM)=0.82 nm and Q=similar to 1,900. To demonstrate the uses for sensing applications, we measure the resonance shifts corresponding to the concentration change of the ambient aqueous solutions of sucrose. DI water is used as the reference for calibration to avoid any other variations, e. g. temperature change. Experiments show that the sensitivities of the MZI racetrack microring sensors with wire and slot waveguides are 101.7 nm/RIU and 166.7 nm/RIU, respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Polarization characterization of a Mach-Zehnder interferometer
    Mabrouki, A
    Gadonna, M
    LeNaour, R
    APPLIED OPTICS, 1996, 35 (19): : 3591 - 3596
  • [42] MACH-ZEHNDER TYPE OF ULTRASONIC INTERFEROMETER
    TURNER, WR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1964, 36 (05): : 1040 - &
  • [43] SPECTRAL CHANGES IN THE MACH-ZEHNDER INTERFEROMETER
    AGARWAL, GS
    JAMES, DFV
    JOURNAL OF MODERN OPTICS, 1993, 40 (08) : 1431 - 1436
  • [44] INITIAL ADJUSTMENT OF THE MACH-ZEHNDER INTERFEROMETER
    PRICE, EW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1952, 23 (04): : 162 - 162
  • [45] A WAVELENGTH-SELECTIVE SWITCH BASED ON MICRORING RESONATORS AND MACH-ZEHNDER INTERFEROMETER SWITCHES
    Miura, Kengo
    Shoji, Yuya
    Mizumoto, Tetsuya
    2013 18TH MICROOPTICS CONFERENCE (MOC), 2013,
  • [46] An interleaver with tunable bandwidth ratio based on microring resonator coupled Mach-Zehnder interferometer
    Xu, Chi
    Zhang, Yundong
    Zhang, Xuenan
    Wang, Kaiyang
    Wu, Yongfeng
    Zhai, Xianxin
    Yuan, Ping
    OPTICS COMMUNICATIONS, 2015, 339 : 148 - 152
  • [47] Mach-Zehnder interferometer for movement monitoring
    Vasinek, Vladimir
    Cubik, Jakub
    Kepak, Stanislav
    Doricak, Jan
    Latal, Jan
    Koudelka, Petr
    FIBER OPTIC SENSORS AND APPLICATIONS IX, 2012, 8370
  • [48] Topologically protected Mach-Zehnder interferometer
    Yang, Peilin
    Jiang, Pengpeng
    Guo, Xiaowei
    Hou, Lianping
    JOURNAL OF OPTICS, 2020, 22 (10)
  • [49] Nonlinear Mach-Zehnder interferometer isolator
    Singh, Neetesh
    Kaertner, Franz X.
    OPTICS EXPRESS, 2022, 30 (04) : 5973 - 5980
  • [50] ALIGNMENT TECHNIQUE FOR MACH-ZEHNDER INTERFEROMETER
    PANARELLA, E
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (06): : 523 - 523