Pull-out capacity of multiple screw fastener connections in cold-formed steel roof battens

被引:12
|
作者
Sivapathasundaram, Mayooran [1 ]
Mahendran, Mahen [1 ]
机构
[1] QUT, Brisbane, Qld, Australia
基金
澳大利亚研究理事会;
关键词
Light gauge steel buildings; Roof battens; Roof purlins; Multiple screw connections; Pull-out failures; Experimental study; Load sharing; Design equations; CLADDINGS; STRENGTH; BEHAVIOR; SUBJECT; DESIGN;
D O I
10.1016/j.jcsr.2018.01.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Light gauge steel roofing systems of low rise buildings are made of high strength steel roof cladding, battens and purlins/rafters/trusses and fastened with self-drilling screws. Localised failures occurring at these screw connections under wind uplift loading often lead to catastrophic losses of steel roofing systems during severe storm events. Pull-out failures occurring at the two bottom flanges of roof batten to purlin/rafter screw connections is one of them. Multiple screw fasteners connecting the bottom flanges of roof battens to purlins/rafters pull out prematurely from the light gauge steel purlins/rafters. Since the structural behaviour of multiple screw connections differs significantly from the behaviour of single screw connections, the pull-out capacity of multiple screw connections cannot be calculated directly based on the number of screw fasteners. Hence a series of 80 small scale pull-out tests was conducted to investigate the pull-out capacities of two and four-screw fastener connections in roof battens. The pull-out failure loads from the tests were first compared with the pull-out capacities predicted using the design equations in the current cold-formed steel design standards. Suitable design modifications were then proposed to accurately calculate the pull-out capacities of roof battens with two and four screw connections, This paper describes the details and the results of this study. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:40 / 52
页数:13
相关论文
共 50 条
  • [32] Evaluation of the pull-out strength of connections with roof cladding using honeycomb panels with cool roof performance capacity
    Sang-Woo Park
    In-Ho Lee
    Kwang-Il Ko
    E. T. Lee
    International Journal of Steel Structures, 2016, 16 : 505 - 516
  • [33] Evaluation of the pull-out strength of connections with roof cladding using honeycomb panels with cool roof performance capacity
    Park, Sang-Woo
    Lee, In-Ho
    Ko, Kwang-Il
    Lee, E. T.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2016, 16 (02) : 505 - 516
  • [34] Numerical studies of pull-through failures in cold-formed steel battens at sub-zero temperatures
    Athmarajah, Gopikrishna
    Mahendran, Mahen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 218
  • [35] Node connections of cold-formed steel structures
    Kurazhova, V. G.
    Nazmeyeva, T. V.
    MAGAZINE OF CIVIL ENGINEERING, 2011, 21 (03): : 47 - +
  • [36] COLD-FORMED STEEL PANELS WITH RIVETED CONNECTIONS
    YENER, M
    WHITE, RN
    JOURNAL OF STRUCTURAL ENGINEERING, 1984, 110 (05) : 1035 - 1050
  • [37] Experimental studies on screw connections between cold-formed steel framing and sandwich sheathing
    Jammi, Ashok
    Jayachandran, S. Arul
    STRUCTURES, 2021, 32 : 2048 - 2059
  • [38] Numerical study on the stiffness and ultimate strength of cold-formed steel C-shaped connectors under pull-out failure
    Obeydi, Marzieh
    Baltork, Iman Mohammadpoor
    Zeynalian, Mehran
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2023, 24 (02) : 173 - 189
  • [39] Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures
    Chen, Wei
    Ye, Jihong
    Chen, Tao
    APPLIED SCIENCES-BASEL, 2016, 6 (09):
  • [40] Pull-out strength of steel roof and wall cladding systems
    Mahendran, M.
    Tang, R.B.