Efficacy of digital breast tomosynthesis for breast cancer diagnosis

被引:1
|
作者
Alakhras, M. [1 ]
Mello-Thoms, C. [1 ]
Rickard, M. [1 ]
Bourne, R. [1 ]
Brennan, P. C. [1 ]
机构
[1] Univ Sydney, MIOPeG Fac Hlth Sci, Lidcombe, NSW, Australia
关键词
Digital breast tomosynthesis; Digital mammography; Breast Cancer; Diagnostic performance; CLINICAL-PERFORMANCE; MAMMOGRAPHY; CALCIFICATIONS; EXPERIENCE; ACCURACY; 2-VIEW;
D O I
10.1117/12.2043321
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Purpose To compare the diagnostic performance of digital breast tomosynthesis (DBT) in combination with digital mammography (DM) with that of digital mammography alone Materials and Methods Twenty six experienced radiologists who specialized in breast imaging read 50 cases (27 cancers and 23 non-cancer cases) of patients who underwent DM and DBT. Both exams included the craniocaudal (CC) and mediolateral oblique (MLO) views. Histopathologic examination established truth in all lesions. Each case was interpreted in two modes, once with DM alone followed by DM+DBT, and the observers were asked to mark the location of any lesions, if present, and give it a score based on a five-category assessment by the Royal Australian and New Zealand College of Radiologists (RANZCR). The diagnostic performance of DM compared with that of DM+DBT was evaluated in terms of the difference between areas under receiver-operating characteristic curves (AUCs), Jackknife free-response receiver operator characteristics (JAFROC) figure-of-merit, sensitivity, location sensitivity and specificity. Results Average AUC and JAFROC for DM versus DM+DBT was significantly different (AUCs 0.690 vs 0.781, p=<0.0001), (JAFROC 0.618 vs. 0.732, p=<0.0001) respectively. In addition, the use of DM+DBT resulted in an improvement in sensitivity (0.629 vs. 0.701, p=0.0011), location sensitivity (0.548 vs. 0.690, p=<0.0001) and specificity (0.656 vs. 0.758, p=0.0015) when compared to DM alone. Conclusion Adding DBT to the standard DM significantly improved radiologists' performance in terms of AUCs, JAFROC figure of merit, sensitivity, location sensitivity and specificity values.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Comparison of Digital Breast Tomosynthesis and Digital Mammography for Detection of Breast Cancer in Kuwaiti Women
    Asbeutah, Akram M.
    Karmani, Nouralhuda
    Asbeutah, AbdulAziz A.
    Echreshzadeh, Yasmin A.
    AlMajran, Abdullah A.
    Al-Khalifah, Khalid H.
    MEDICAL PRINCIPLES AND PRACTICE, 2019, 28 (01) : 10 - 15
  • [42] Imaging Surveillance of Breast Cancer Survivors with Digital Mammography versus Digital Breast Tomosynthesis
    Bahl, Manisha
    Mercaldo, Sarah
    McCarthy, Anne Marie
    Lehman, Constance D.
    RADIOLOGY, 2021, 298 (02) : 308 - 316
  • [43] Implications of Digital Breast Tomosynthesis in Breast Cancer Screening: Reducing Advanced Breast Cancers
    Kim, Soo-Yeon
    Woo, Ok Hee
    RADIOLOGY, 2024, 312 (03)
  • [44] Tumor Characteristics and Molecular Subtypes in Breast Cancer Screening with Digital Breast Tomosynthesis: The Malmo Breast Tomosynthesis Screening Trial
    Johnson, Kristin
    Zackrisson, Sophia
    Rosso, Aldana
    Sartor, Hanna
    Saal, Lao H.
    Andersson, Ingvar
    Lang, Kristina
    RADIOLOGY, 2019, 293 (02) : 273 - 281
  • [45] Outcomes by Race in Breast Cancer Screening With Digital Breast Tomosynthesis Versus Digital Mammography
    Alsheik, Nila
    Blount, Linda
    Qiong, Qiu
    Talley, Melinda
    Pohlman, Scott
    Troeger, Kathleen
    Abbey, Genevieve
    Mango, Victoria L.
    Pollack, Erica
    Chong, Alice
    Donadio, Greg
    Behling, Michael
    Mortimer, Kathleen
    Conant, Emily
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2021, 18 (07) : 906 - 918
  • [46] Breast Density and Breast Cancer Screening with Digital Breast Tomosynthesis: A TOSYMA Trial Subanalysis
    Weigel, Stefanie
    Heindel, Walter
    Hense, Hans-Werner
    Decker, Thomas
    Gerss, Joachim
    Kerschke, Laura
    TOSYMA Screening Trial Study Grp
    RADIOLOGY, 2023, 306 (02)
  • [47] Breast Cancer Detection: Digital Breast Tomosynthesis with Synthesized Mammography versus Digital Mammography
    Ha, Su Min
    Chang, Jung Min
    RADIOLOGY, 2023, 309 (03)
  • [48] Lesion-specific exposure parameters for breast cancer diagnosis on digital breast tomosynthesis and full-field digital mammography
    Ma, Le
    Liu, Hui
    Lin, Xiaojia
    Cai, Yuxing
    Zhang, Ling
    Chen, Weiguo
    Qin, Genggeng
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 77
  • [49] Leveraging Quantum Kernel Support Vector Machine for breast cancer diagnosis from Digital Breast Tomosynthesis images
    Aswiga, R. V.
    Sridevi, S.
    Indira, B.
    QUANTUM MACHINE INTELLIGENCE, 2024, 6 (02)
  • [50] Evolutionary pruning of transfer learned deep convolutional neural network for breast cancer diagnosis in digital breast tomosynthesis
    Samala, Ravi K.
    Chan, Heang-Ping
    Hadjiiski, Lubomir M.
    Helvie, Mark A.
    Richter, Caleb
    Cha, Kenny
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09):