Improving air-cooled condenser performance in combined cycle power plants

被引:37
|
作者
Gadhamshetty, V. [1 ]
Nirmalakhandan, N. [1 ]
Myint, M. [1 ]
Ricketts, C. [1 ]
机构
[1] New Mexico State Univ, Civil Engn Dept, Las Cruces, NM 88003 USA
关键词
D O I
10.1061/(ASCE)0733-9402(2006)132:2(81)
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
It has been recognized in recent times that air-cooled condensers (ACCs) are environmentally preferable to the traditional water-cooled condensers for rejecting heat in combined-cycle power plants (CCPPs). However, a drawback of ACCs is that their performance can decline with increasing ambient air temperature. A new approach is proposed in this paper that has the potential to alleviate this drawback of ACCs. In this approach, a chilled-water thermal energy storage system (TES) is used to precool the inflow air to the ACC whenever the ambient air temperature increases above the design air inlet temperature. The temperature of the TES system is maintained by an absorption refrigeration system (ARS) driven by low-quality waste heat from the CCPR A process model integrating the CCPP with the ARS and the TES has been developed to optimize the volume of the TES. A 500 MW CCPP with steam turbine net output of 170.9 MW was chosen to evaluate the application of this approach for a power plant to be located in southern New Mexico. This analysis showed that a tank volume of 4,500 m 3 will be required to maintain the air temperature at the inlet to the ACC at the design value of 20 degrees C throughout the year. Simulations under ambient air temperatures up to 40 degrees C indicated that the proposed system is capable of maintaining the rated net power output of the plant with minimal fluctuations. Simulations also showed that TES tank volume is most sensitive to the design air inlet temperature to the ACC-an increase of this temperature by VC can result in at least 25% reduction in the volume.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [21] Effects of diffuser orifice plate on the performance of air-cooled steam condenser
    Zhang, Xuelei
    Wu, Tingting
    APPLIED THERMAL ENGINEERING, 2016, 98 : 179 - 188
  • [22] Performance Assessment of Air-Cooled Steam Condenser with Guide Vane Cascade
    Zhang Xuelei
    Li Yunpeng
    Chen Haiping
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (05) : 993 - 1003
  • [23] Performance trends of an air-cooled steam condenser under windy conditions
    van Rooyen, J. A.
    Kroger, D. G.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2008, 130 (02):
  • [24] Performance Assessment of Air-Cooled Steam Condenser with Guide Vane Cascade
    ZHANG Xuelei
    LI Yunpeng
    CHEN Haiping
    JournalofThermalScience, 2019, 28 (05) : 993 - 1003
  • [25] A numerical analysis of windscreen effects on air-cooled condenser fan performance
    Venter, A. J.
    Owen, M. T. F.
    Muiyser, J.
    APPLIED THERMAL ENGINEERING, 2021, 186
  • [26] Performance Assessment of Air-Cooled Steam Condenser with Guide Vane Cascade
    Xuelei Zhang
    Yunpeng Li
    Haiping Chen
    Journal of Thermal Science, 2019, 28 : 993 - 1003
  • [27] Uniformity Index as a Universal Air-Cooled Condenser Fan Performance Metric
    Marincowitz, Fredrik
    Owen, Michael
    Muiyser, Jacques
    Holkers, Peter
    INTERNATIONAL JOURNAL OF TURBOMACHINERY PROPULSION AND POWER, 2022, 7 (04)
  • [28] THE EFFECT OF HUB CONFIGURATION ON THE PERFORMANCE OF AN AIR-COOLED STEAM CONDENSER FAN
    Meiring, Z.
    van der Spuy, S. J.
    Meyer, C. J.
    PROCEEDINGS OF THE ASME TURBO EXPO 2020: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 1, 2020,
  • [29] Air-cooled generators for gas turbine power plants
    Diesel & Gas Turbine Worldwide, 1997, 29 (08):
  • [30] PERFORMANCE OF AIR-COOLED POWER PLANTS USING GAS FROM COAL.
    Anon
    Electric Power Research Institute, Advanced Power Systems Division, (Report) EPRI AP, 1981,