Surveillance of Unruptured Intracranial Saccular Aneurysms Using Noncontrast 3D-Black-Blood MRI: Comparison of 3D-TOF and Contrast-Enhanced MRA with 3D-DSA

被引:22
|
作者
Zhu, C. [1 ]
Wang, X. [2 ,3 ]
Eisenmenger, L. [1 ]
Tian, B. [2 ]
Liu, Q. [2 ]
Degnan, A. J. [4 ]
Hess, C. [1 ]
Saloner, D. [1 ]
Lu, J. [2 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Changhai Hosp, Dept Radiol, Shanghai, Peoples R China
[3] Northern Mil Command, Gen Hosp, Dept Radiol, Shenyang, Liaoning, Peoples R China
[4] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
基金
中国国家自然科学基金; 美国国家卫生研究院;
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; GUGLIELMI DETACHABLE COILS; FAST SPIN-ECHO; CT ANGIOGRAPHY; VESSEL WALL; FOLLOW-UP; CEREBRAL ANEURYSMS; ARTERY ANEURYSMS; NATURAL-HISTORY; TIME;
D O I
10.3174/ajnr.A6080
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Patients with unruptured intracranial aneurysms routinely undergo surveillance imaging to monitor growth. Angiography is the criterion standard for aneurysm diagnosis, but it is invasive. This study aimed to evaluate the accuracy and reproducibility of a 3D noncontrast black-blood MR imaging technique for unruptured intracranial aneurysm measurement in comparison with 3D-TOF and contrast-enhanced MRA, using 3D rotational angiography as a reference standard. MATERIALS AND METHODS: Sixty-four patients (57.3 +/- 10.9 years of age, 41 women) with 68 saccular unruptured intracranial aneurysms were recruited. Patients underwent 3T MR imaging with 3D-TOF-MRA, 3D black-blood MR imaging, and contrast-enhanced MRA, and they underwent 3D rotational angiography within 2 weeks. The neck, width, and height of the unruptured intracranial aneurysms were measured by 2 radiologists independently on 3D rotational angiography and 3 MR imaging sequences. The accuracy and reproducibility were evaluated by Bland-Altman plots, the coefficient of variance, and the intraclass correlation coefficient. RESULTS: 3D black-blood MR imaging demonstrates the best agreement with DSA, with the smallest limits of agreement and measurement error (coefficients of variance range, 5.87%-7.04%). 3D-TOF-MRA had the largest limits of agreement and measurement error (coefficients of variance range, 12.73%-15.78%). The average coefficient of variance was 6.26% for 3D black-blood MR imaging, 7.03% for contrast-enhanced MRA, and 15.54% for TOF-MRA. No bias was found among 3 MR imaging sequences compared with 3D rotational angiography. All 3 MR imaging sequences had excellent interreader agreement (intraclass correlation coefficient, > 0.95). 3D black-blood MR imaging performed the best for patients with intraluminal thrombus (n = 10). CONCLUSIONS: 3D black-blood MR imaging achieves better accuracy for aneurysm size measurements compared with 3D-TOF, using 3D rotational angiography as a criterion standard. This noncontrast technique is promising for surveillance of unruptured intracranial aneurysms.
引用
收藏
页码:960 / 966
页数:7
相关论文
共 50 条
  • [31] Evaluation of intracranial aneurysm: Comparison between ZTE-MRA and 3D-TOF-MRA
    Lyu, J.
    Sha, L.
    Qi, X.
    Chen, Z.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (03): : 723 - 725
  • [32] Building Three-Dimensional Intracranial Aneurysm Models from 3D-TOF MRA: a Validation Study
    Turker Acar
    Asli Beril Karakas
    Mehmet Asim Ozer
    Ali Murat Koc
    Figen Govsa
    Journal of Digital Imaging, 2019, 32 : 963 - 970
  • [33] Peripheral contrast-enhanced 3D MRA with 1.0 M Gadobutrol
    Herborn, CU
    EUROPEAN RADIOLOGY, 2004, 14 : M23 - M25
  • [34] Building Three-Dimensional Intracranial Aneurysm Models from 3D-TOF MRA: a Validation Study
    Acar, Turker
    Karakas, Asli Beril
    Ozer, Mehmet Asim
    Koc, Ali Murat
    Govsa, Figen
    JOURNAL OF DIGITAL IMAGING, 2019, 32 (06) : 963 - 970
  • [35] Deep Learning-Based Detection of Intracranial Aneurysms in 3D TOF-MRA
    Sichtermann, T.
    Faron, A.
    Sijben, R.
    Teichert, N.
    Freiherr, J.
    Wiesmann, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (01) : 25 - 32
  • [36] Renal artery aneurysms: diagnosis and surveillance with 3D contrast-enhanced magnetic resonance angiography
    Ronan F. J. Browne
    Elaine O. Riordan
    Jacqueline A. Roberts
    John P. Ridgway
    Graham Woodrow
    Michael Gough
    Dermot Moore
    James F. M. Meaney
    European Radiology, 2004, 14 : 1807 - 1812
  • [37] Renal artery aneurysms: diagnosis and surveillance with 3D contrast-enhanced magnetic resonance anglography
    Browne, RFJ
    Riordan, EO
    Roberts, JA
    Ridgway, JP
    Woodrow, G
    Gough, M
    Moore, D
    Meaney, JFM
    EUROPEAN RADIOLOGY, 2004, 14 (10) : 1807 - 1812
  • [38] Contrast-enhanced MRA (efgre3d) for the preoperative MR imaging of meningiomas
    Suzuki, M
    Matsui, O
    Ueda, E
    Katagiri, A
    Saitoh, C
    Kobayashi, K
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (05): : 1027 - 1028
  • [39] Visceral artery aneurysms: Evaluation using 3D contrast-enhanced MR angiography
    Liu, Qi
    Lu, Jian Ping
    Wang, Fei
    Wang, Li
    Jin, Ai Guo
    Wang, Jian
    Tian, Jian Ming
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (03) : 826 - 833
  • [40] Improve temporal and spatial resolution in contrast-enhanced 3D MRA using paralle imaging
    Quijano, CV
    Chen, Q
    Li, W
    Storey, P
    Mai, VM
    Edelman, RT
    RADIOLOGY, 2002, 225 : 571 - 572