A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet

被引:28
|
作者
Yu, Ke-zhi [1 ,2 ]
Ding, Guo-liang [1 ]
Chen, Tian-ji [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Shanghai Ocean Univ, Dept Refrigerat Engn, Shanghai 201306, Peoples R China
关键词
Air curtain; Computational fluid dynamics; Correlation model; Display cabinet; Thermal entrainment factor; 2-FLUID MODEL; SIMULATION; PERFORMANCE; EVAPORATORS; DESIGN;
D O I
10.1016/j.applthermaleng.2009.02.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal entrainment factor (TEF) is an important parameter to describe the cold preservation performance of a display cabinet. In order to calculate the TEF of a display cabinet rapidly and accurately, the method of establishing a correlation model based on computational fluid dynamics (CFD) simulation results is presented and the correlation model of TEF for typical single and double air curtain in a vertical open display cabinet is developed in this paper. The TEF of display cabinet predicted by the correlation model gives a maximum deviation of -9.4% and a mean deviation of -0.1% compared with the published experimental data. In addition, the correlation model can be used to calculate the air curtain return temperature, showing a maximum deviation of 0.9 degrees C and an average deviation of 0.1 degrees C compared with the published experimental data. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2904 / 2913
页数:10
相关论文
共 42 条
  • [21] Modified two-fluid model for air curtains in open vertical display cabinets
    Yu, Ke-zhi
    Ding, Guo-liang
    Chen, Tian-ji
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03): : 472 - 482
  • [22] Numerical analysis of different diffuser and vent numbers in a commercial display cabinet with air curtain for different environmental velocities
    Gungunes, H. M.
    Baskaya, S.
    Calisir, T.
    Koseoglu, M. F.
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON TURBULENCE HEAT AND MASS TRANSFER (THMT-15), 2015, : 875 - 878
  • [23] DEPENDENCY OF AIR CURTAIN PERFORMANCE ON DISCHARGE AIR VELOCITY (GRILLE AND BACK PANEL) IN OPEN REFRIGERATED DISPLAY CABINETS
    Gaspar, Pedro Dinis
    Carrilho Goncalves, L. C.
    Voegeli, Andreas
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 9, PTS A-C, 2010, : 1067 - 1076
  • [24] Prediction of the average surface heat transfer coefficient for model foodstuffs in a vertical display cabinet
    Hoke, Karel
    Landfeld, Ales
    Severa, Jiri
    Kyhos, Karel
    Zitny, Rudolf
    Houska, Milan
    CZECH JOURNAL OF FOOD SCIENCES, 2008, 26 (03) : 199 - 210
  • [25] THREE-DIMENSIONAL CFD MODELLING AND ANALYSIS OF THE THERMAL ENTRAINMENT IN OPEN REFRIGERATED DISPLAY CABINETS
    Gaspar, Pedro Dinis
    Carrilho Goncalves, L. C.
    Pitarma, R. A.
    HT2008: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2008, VOL 2, 2009, : 63 - 73
  • [26] Experimental and Numerical Study of the Performance of an Open-Type Multi-Deck Refrigerated Cabinet with Single and Dual Air Curtain
    Vengalis, Tadas
    Moksin, Vadim
    APPLIED SCIENCES-BASEL, 2023, 13 (16):
  • [27] Numerical and experimental investigation of energy efficiency by applying phase change material to open vertical type refrigerated display cabinet
    Celik, Ayse Burcu
    Pulat, Erhan
    Sokmen, Furkan
    Balkan, Cagri
    Coskun, Salih
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2023, 38 (03): : 1453 - 1465
  • [28] A novel optimization strategy for the design of air curtains for open vertical refrigerated display cases
    Cao, Zhikun
    Han, Hua
    Gu, Bo
    APPLIED THERMAL ENGINEERING, 2011, 31 (16) : 3098 - 3105
  • [29] Improvement of air distribution in refrigerated vertical open front remote supermarket display cases
    Gray, I.
    Luscombe, P.
    McLean, L.
    Sarathy, C. S. P.
    Sheahen, P.
    Srinivasan, K.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05): : 902 - 910
  • [30] A simplified thermal CFD approach to fins and tube heat exchanger: Application to maldistributed airflow on an open display cabinet
    Rossetti, A.
    Minetto, S.
    Marinetti, S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 57 : 208 - 215