Long-Term Monitoring of Thermocouple Stability with Miniature Fixed-Point Cells

被引:6
|
作者
Elliott, C. J. [1 ]
Failleau, G. [2 ]
Deuze, T. [2 ]
Sadli, M. [2 ]
Pearce, J. V. [1 ]
Machin, G. [1 ]
机构
[1] Natl Phys Lab, Temp & Humid Grp, Teddington TW11 0LW, Middx, England
[2] Lab Commun Metrol LNE Cnam, La Plaine St Denis, France
关键词
Fixed point; High temperature; Self-validation; Thermocouple;
D O I
10.1007/s10765-014-1597-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the framework of the European Metrology Research Programme ENG08 "MetroFission" project, two National Measurement Institutes, LNE-Cnam (France) and NPL (UK), have cooperatively developed methods of in situ validation of thermocouple output for application in next-generation nuclear fission power plants. Miniature fixed-point cells for use at three temperatures were constructed in the first step of this project: at the freezing point of silver (), the freezing point of copper (), and the melting point of the iron-carbon eutectic (). This paper reports the results of a second step in the study, where the robustness of the self-validation method has been investigated. Typical industrial Type N thermocouples have been employed with each of the miniature fixed-point devices installed, and repeatedly thermally cycled through the melting and freezing transitions of the fixed-point ingots. The devices have been exposed to a total of up to 90 h in the molten state. Furthermore, the LNE-Cnam devices were also subjected to fast cool-down rates, on five occasions, where the rate is estimated to have been between and . The devices are shown to be repeatable, reliable, and robust over the course of these tests. The drift of the Type N thermocouple has been identified separately to the behavior of the device. A reliable method for improving thermocouple performance and process control is therefore demonstrated. Requirements for implementation and the advantages of each approach for monitoring and correcting thermocouple drift are discussed, and an uncertainty budget for self-validation is presented.
引用
收藏
页码:560 / 573
页数:14
相关论文
共 50 条
  • [41] Effect of bushings in thermometric fixed-point cells
    Zuzek, V.
    Batagelj, V.
    Drnovsek, J.
    Bojkovski, J.
    MEASUREMENT, 2016, 78 : 289 - 295
  • [42] New SMU Gallium Fixed-Point Cells
    Juraj Ranostaj
    Stanislav Ďuriš
    Renáta Knorová
    Mariana Kaskötö
    Irena Vyskočilová
    International Journal of Thermophysics, 2011, 32 : 1535 - 1543
  • [43] An Experimental Investigation of the Long-Term Stability of Triple-Point-of-Water Cells
    K. D. Hill
    International Journal of Thermophysics, 2014, 35 : 611 - 619
  • [44] An Experimental Investigation of the Long-Term Stability of Triple-Point-of-Water Cells
    Hill, K. D.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 611 - 619
  • [45] New SMU Gallium Fixed-Point Cells
    Ranostaj, Juraj
    Duris, Stanislav
    Knorova, Renata
    Kaskoetoe, Mariana
    Vyskocilova, Irena
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (7-8) : 1535 - 1543
  • [46] Nonlinear Random Stability via Fixed-Point Method
    Cho, Yeol Je
    Kang, Shin Min
    Saadati, Reza
    JOURNAL OF APPLIED MATHEMATICS, 2012,
  • [47] Voltage Stability Analysis and Online Monitoring Method Based on Fixed-Point Principle and Spectrum Calculation
    Li, Fan
    Wang, Fang-zong
    Yang, Xue-tao
    Song, Dun-wen
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONIC ENGINEERING (EEE 2019), 2019, 185 : 5 - 14
  • [48] Accurate numerical model for characteristic temperature acquisition of miniature fixed-point blackbodies
    Sima, Rui-Heng
    Hao, Xiao-Peng
    Song, Jian
    Qi, Hong
    Yuan, Zun-Dong
    MEASUREMENT, 2021, 168
  • [49] A New Co-C Eutectic Fixed-Point Cell for Thermocouple Calibration at 1324 °C
    Failleau, G.
    Deuze, T.
    Jouin, D.
    Mokdad, S.
    Briaudeau, S.
    Sadli, M.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (6-7) : 1190 - 1201
  • [50] Self-testable industrial platinum resistance thermometers integrated with miniature mercury and indium fixed-point cells
    Kang, Kee Hoon
    Kim, Yong-Gyoo
    Gam, Kee Sool
    Yang, Inseok
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (09) : 3005 - 3008