Digital Variance Angiography in Lower-Limb Angiography with Metal Implants

被引:8
|
作者
Bastian, M. B. [1 ]
Koenig, A. M. [1 ]
Viniol, S. [1 ]
Gyano, M. [2 ,5 ]
Szollosi, D. [3 ,5 ]
Gog, I [4 ,5 ]
Kiss, J. P. [5 ]
Osvath, S. [3 ,5 ]
Szigeti, K. [3 ,5 ]
Mahnken, A. H. [1 ]
Thomas, R. P. [1 ]
机构
[1] Philipps Univ Marburg, Univ Hosp Marburg, Dept Diagnost & Intervent Radiol, Baldingerstr 1, D-35043 Marburg, Germany
[2] Semmelweis Univ, Heart & Vasc Ctr, Dept Intervent Radiol, Budapest, Hungary
[3] Semmelweis Univ, Dept Biophys & Radiat Biol, Budapest, Hungary
[4] Hungarian Def Forces Med Ctr, Dept Vasc Surg, Budapest, Hungary
[5] Kinepict Hlth Ltd, Budapest, Hungary
关键词
Digital variance angiography; Contrast-to-noise ratio; Automated exposure control; Metal implants; CARBON-DIOXIDE; IMAGE QUALITY;
D O I
10.1007/s00270-020-02697-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The presence of metal implants may reduce angiographic image quality due to automated beam adjustments. Digital variance angiography (DVA) is reported to be superior to digital subtraction angiography (DSA) with increased contrast-to-noise ratio (CNR) and better image quality. The aim of the study was to evaluate whether DVA could counterbalance the image quality impairment of lower-limb angiographies with metal implants. Materials and Methods From November 2019 to January 2020, 85 raw lower-limb iodine contrast angiograms of 12 patients with metal implants were processed retrospectively with DVA analyses. For objective comparison, CNR of DSA and DVA images was calculated and the ratio CNRDVA/CNRDSA was determined. Visual image quality was evaluated in a paired comparison and by a five-grade Likert scale by three experienced radiologists. Results The CNR was calculated and compared in 1252 regions of interest in 37 image pairs containing metal implants. The median ratio of CNRDVA/CNRDSA was 1.84 with an interquartile range of 1.35-2.32. Paired comparison resulted in 84.5% in favour of DVA with an interrater agreement of 83.2% (Fleiss kappa 0.454, p < 0.001). The overall image quality scores for DSA and DVA were 3.64 +/- 0.08 and 4.43 +/- 0.06, respectively (p < 0.001, Wilcoxon signed-rank test) with consistently higher individual ratings for DVA. Conclusion Our small-sample pilot study shows that DVA provides significantly improved image quality in lower-limb angiography with metal implants, compared to DSA imaging. The improved CNR suggest that this approach could reduce radiation exposure for lower-limb angiography with metal implants.
引用
收藏
页码:452 / 459
页数:8
相关论文
共 50 条
  • [31] Value of routine angiography before traumatic lower-limb reconstruction with microvascular free tissue transplantation
    Lutz, BS
    Ng, SH
    Cabailo, R
    Lin, CH
    Wei, FC
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1998, 44 (04): : 682 - 686
  • [32] COLOR-CODED DOPPLER SONOGRAPHY OF THE PELVIC AND LOWER-LIMB ARTERIES - A COMPARISON OF THE METHOD WITH ANGIOGRAPHY
    METZ, V
    BRAUNSTEINER, A
    GRABENWOGER, F
    DOCK, W
    HUBSCH, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 149 (03): : 314 - 316
  • [33] Initial Operating Room Experience with Digital Variance Angiography in Carbon Dioxide-Assisted Lower Limb Interventions: A Pilot Study
    Gyano, Marcell
    Csobay-Novak, Csaba
    Berczeli, Marton
    Gog, Istvan
    Kiss, Janos P.
    Szigeti, Krisztian
    Osvath, Szabolcs
    Nemes, Balazs
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (08) : 1226 - 1231
  • [34] Initial Operating Room Experience with Digital Variance Angiography in Carbon Dioxide-Assisted Lower Limb Interventions: A Pilot Study
    Marcell Gyánó
    Csaba Csobay-Novák
    Márton Berczeli
    István Góg
    János P. Kiss
    Krisztián Szigeti
    Szabolcs Osváth
    Balázs Nemes
    CardioVascular and Interventional Radiology, 2020, 43 : 1226 - 1231
  • [35] Digital variance angiography in patients undergoing lower limb arterial recanalization: cost-effectiveness analysis within the English healthcare setting
    Ansaripour, Amir
    Moloney, Eoin
    Branagan-Harris, Michael
    Patrone, Lorenzo
    Javanbakht, Mehdi
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2024, 13 (04)
  • [37] The evaluation of lower limb arteriopathy by multidetector computed tomography compared with digital subtraction angiography
    Ferrer, Ma D.
    Revert, A. J.
    Pallardo, Y.
    Esteban, E.
    Jornet, J.
    Molla, E.
    RADIOLOGIA, 2006, 48 (06): : 369 - 374
  • [38] Initial Experience Using Digital Variance Angiography in Context of Prostatic Artery Embolization in Comparison with Digital Subtraction Angiography
    Alizadeh, Leona S.
    Gyano, Marcell
    Gog, Istvan
    Szigeti, Krisztian
    Osvath, Szabolcs
    Kiss, Janos P.
    Yel, Ibrahim
    Koch, Vitali
    Gruenewald, Leon D.
    Vogl, Thomas J.
    Booz, Christian
    ACADEMIC RADIOLOGY, 2023, 30 (04) : 689 - 697
  • [39] Magnetic resonance angiography compared with digital subtraction angiography in patients with critical limb ischemia
    Herrera Mingorance, J. D.
    Lozano Alonso, S.
    Linares Palomino, J. P.
    Ros Vidal, R.
    Cuenca Manteca, J. B.
    Salmeron Febres, L. M.
    ANGIOLOGIA, 2015, 67 (06): : 470 - 475
  • [40] Comparison between automated carbon dioxide digital angiography and standard iodinated contrast media angiography for lower limb arterial disease evaluation
    Scalise, F.
    Auguadro, C.
    Sorropago, G.
    Sorropago, A.
    Zannoli, R.
    CORONARY ARTERY DISEASE 2015, 2016, : 61 - 64