Digital Variance Angiography in Lower-Limb Angiography with Metal Implants

被引:8
|
作者
Bastian, M. B. [1 ]
Koenig, A. M. [1 ]
Viniol, S. [1 ]
Gyano, M. [2 ,5 ]
Szollosi, D. [3 ,5 ]
Gog, I [4 ,5 ]
Kiss, J. P. [5 ]
Osvath, S. [3 ,5 ]
Szigeti, K. [3 ,5 ]
Mahnken, A. H. [1 ]
Thomas, R. P. [1 ]
机构
[1] Philipps Univ Marburg, Univ Hosp Marburg, Dept Diagnost & Intervent Radiol, Baldingerstr 1, D-35043 Marburg, Germany
[2] Semmelweis Univ, Heart & Vasc Ctr, Dept Intervent Radiol, Budapest, Hungary
[3] Semmelweis Univ, Dept Biophys & Radiat Biol, Budapest, Hungary
[4] Hungarian Def Forces Med Ctr, Dept Vasc Surg, Budapest, Hungary
[5] Kinepict Hlth Ltd, Budapest, Hungary
关键词
Digital variance angiography; Contrast-to-noise ratio; Automated exposure control; Metal implants; CARBON-DIOXIDE; IMAGE QUALITY;
D O I
10.1007/s00270-020-02697-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The presence of metal implants may reduce angiographic image quality due to automated beam adjustments. Digital variance angiography (DVA) is reported to be superior to digital subtraction angiography (DSA) with increased contrast-to-noise ratio (CNR) and better image quality. The aim of the study was to evaluate whether DVA could counterbalance the image quality impairment of lower-limb angiographies with metal implants. Materials and Methods From November 2019 to January 2020, 85 raw lower-limb iodine contrast angiograms of 12 patients with metal implants were processed retrospectively with DVA analyses. For objective comparison, CNR of DSA and DVA images was calculated and the ratio CNRDVA/CNRDSA was determined. Visual image quality was evaluated in a paired comparison and by a five-grade Likert scale by three experienced radiologists. Results The CNR was calculated and compared in 1252 regions of interest in 37 image pairs containing metal implants. The median ratio of CNRDVA/CNRDSA was 1.84 with an interquartile range of 1.35-2.32. Paired comparison resulted in 84.5% in favour of DVA with an interrater agreement of 83.2% (Fleiss kappa 0.454, p < 0.001). The overall image quality scores for DSA and DVA were 3.64 +/- 0.08 and 4.43 +/- 0.06, respectively (p < 0.001, Wilcoxon signed-rank test) with consistently higher individual ratings for DVA. Conclusion Our small-sample pilot study shows that DVA provides significantly improved image quality in lower-limb angiography with metal implants, compared to DSA imaging. The improved CNR suggest that this approach could reduce radiation exposure for lower-limb angiography with metal implants.
引用
收藏
页码:452 / 459
页数:8
相关论文
共 50 条
  • [1] Digital Variance Angiography in Lower-Limb Angiography with Metal Implants
    M. B. Bastian
    A. M. König
    S. Viniol
    M. Gyánó
    D. Szöllősi
    I. Góg
    J. P. Kiss
    S. Osvath
    K. Szigeti
    A. H. Mahnken
    R. P. Thomas
    CardioVascular and Interventional Radiology, 2021, 44 : 452 - 459
  • [2] Digital Variance Angiography in Selective Lower Limb Interventions
    Thomas, Rohit P.
    Bastian, Moritz B.
    Viniol, Simon
    Koenig, Alexander M.
    Amin, Sandeep S.
    Eldergash, Osama
    Schnabel, Johannes
    Gyano, Marcell
    Szollosi, David
    Gog, Istvan
    Kiss, Janos P.
    Osvath, Szabolcs
    Szigeti, Krisztian P.
    Mahnken, Andreas H.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 33 (02) : 104 - 112
  • [3] LOWER-LIMB ANGIOGRAPHY IN LEPROSY
    JOHNSON, AC
    REDDY, R
    JOHNSON, S
    JAMES, AE
    RADIOLOGY, 1978, 126 (02) : 327 - 332
  • [4] Radiation Exposure Reduction by Digital Variance Angiography in Lower Limb Angiography: A Randomized Controlled Trial
    Sotonyi, Peter
    Berczeli, Marton
    Gyano, Marcell
    Legeza, Peter
    Mihaly, Zsuzsanna
    Csobay-Novak, Csaba
    Pataki, Akos
    Juhasz, Viktoria
    Gog, Istvan
    Szigeti, Krisztian
    Osvath, Szabolcs
    Kiss, Janos P.
    Nemes, Balazs
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (05)
  • [5] TECHNIQUES FOR LOWER-LIMB ANGIOGRAPHY - A COMPARATIVE-STUDY
    SMITH, TP
    CRAGG, AH
    BERBAUM, KS
    RYALS, TJ
    SATO, Y
    RADIOLOGY, 1990, 174 (03) : 951 - 955
  • [6] PULSED DOPPLER ANGIOGRAPHY IN LOWER-LIMB ARTERIAL ISCHEMIA
    BAIRD, RN
    LUSBY, RJ
    BIRD, DR
    GIDDINGS, AEB
    SKIDMORE, R
    WOODCOCK, JP
    HORTON, RE
    PEACOCK, JH
    SURGERY, 1979, 86 (06) : 818 - 825
  • [7] THE RESULTS OF COMPLETION ANGIOGRAPHY AFTER ACUTE LOWER-LIMB THROMBOEMBOLECTOMY
    HANSEN, CP
    RASCH, L
    HOLTVEG, H
    HOLSTEIN, P
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1991, 80 (03) : 271 - 273
  • [8] DIGITAL VIDEO SUBTRACTION ANGIOGRAPHY (DVSA) OF THE ABDOMINAL-AORTA AND THE PELVIC AND LOWER-LIMB ARTERIES
    HARDER, T
    JANSON, R
    LACKNER, K
    FRANKEN, T
    FISCHER, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1983, 138 (03): : 301 - 309
  • [9] PERIPHERAL ANGIOPLASTY - EMPHASIZING THE NEED FOR COMPLETE VISUALIZATION IN LOWER-LIMB ANGIOGRAPHY
    PROCTER, AE
    CUMBERLAND, DC
    CLINICAL RADIOLOGY, 1985, 36 (03) : 321 - 326
  • [10] DIGITAL DISTAL LOWER-LIMB ANGIOGRAPHY - COMPARISON OF SELECTIVE ILIAC INJECTION WITH VASODILATORS AND BOLUS CHASING TECHNIQUE
    PODEUR, L
    ROLLAND, Y
    LUCAS, A
    FERTE, L
    RAMBEAU, M
    PROVENSOL, T
    DUVAUFERRIER, R
    EUROPEAN RADIOLOGY, 1995, 5 (02) : 140 - 144