Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation

被引:35
|
作者
Huang, Zhaoya [1 ,2 ]
Ni, Youyi [3 ]
Wang, Hai [4 ]
Zheng, Jian [1 ]
Yamazaki, Shinnosuke [1 ]
Sakaguchi, Aya [5 ]
Long, Xinggui [2 ]
Uchida, Shigeo [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Dept Radioecol & Fukushima Project, Inage Ku, 491 Anagawa, Chiba 2638555, Japan
[2] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Sichuan, Peoples R China
[3] Peking Univ, Sch Phys, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[4] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Peoples R China
[5] Univ Tsukuba, Ctr Res Isotopes & Environm Dynam, Tsukuba, Ibaraki, Japan
关键词
Np-237; Pu isotope; Anion-exchange chromatography; SF-ICP-MS; Soil; ENVIRONMENTAL-SAMPLES; ATOMIC SPECTROMETRY; RAPID-DETERMINATION; PLUTONIUM; FIELD; RADIONUCLIDES; FOREST; AM-241; AM; NP;
D O I
10.1016/j.microc.2019.05.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a method developed for simultaneous analysis of ultra-trace level Np-237 and Pu isotopes in soil and sediment samples by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Pu-242 was used as a yield tracer for Np-237 as well as for Pu isotopes. A simple single chromatographic column packed with anion exchange resin (AG MP-1M) was used for the separation of Np-237 and Pu isotopes from the matrix elements and other potential interferences. The SF-ICP-MS measurement precision of the Np-237/Pu-242 atom ratio for sub-fg/mL level Np-237 and (PU)-P-242 was 0.97%, and the overall fractionation between Np-237 and (PU)-P-242 for the whole analysis procedure was 1.010 +/- 0.038. Besides, the single column chromatographic separation realized high decontamination factor of U (1.8 x 10(6) to 1.7 x 10(7)), and that ensured the interference effect of U-238 to the Np-237, Pu-239 and Pu-240 measurements was negligible or could be easily corrected. Four standard reference materials were analyzed for method validation, and the results illustrated Pu-242 was an effective non-isotopic tracer for Np-237 determination. Finally, the developed method was successfully employed in the analysis of the global fallout level of Np-237 and Pu isotopes in Japanese paddy soil samples to study their environmental behaviors.
引用
收藏
页码:597 / 604
页数:8
相关论文
共 38 条
  • [31] Improved radioanalytical method for the simultaneous determination of Th, U, Np, Pu and Am(Cm) on a single TRU column by alpha spectrometry and ICP-MS
    Macsik, Z.
    Groska, J.
    Vajda, N.
    Vogt, S.
    Kis-Benedek, G.
    Kim, C. S.
    Maddison, A.
    Donohue, D.
    RADIOCHIMICA ACTA, 2013, 101 (04) : 241 - 251
  • [32] Simultaneous multi-element analysis of trace elements in soil samples by means of high-resolution inductively coupled plasma sector field mass spectrometry (SF-ICP-MS)
    Latkoczy, C
    Prohaska, T
    Stingeder, G
    Wenzel, WW
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (2-3): : 256 - 262
  • [33] Simultaneous multi-element analysis of trace elements in soil samples by means of high-resolution inductively coupled plasma sector field mass spectrometry (SF-ICP-MS)
    C. Latkoczy
    Thomas Prohaska
    Gerhard Stingeder
    Walter W. Wenzel
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 256 - 262
  • [34] Rapid determination of plutonium isotopes in small samples using single anion exchange separation and ICP-MS/MS measurement in NH3-He mode for sediment dating
    Xu, Yihong
    Li, Chen
    Yu, Haiping
    Fang, Fengman
    Hou, Xiaolin
    Zhang, Chao
    Li, Xiaofei
    Xing, Shan
    TALANTA, 2022, 240
  • [35] Rapid determination of plutonium isotopes in small samples using single anion exchange separation and ICP-MS/MS measurement in NH3–He mode for sediment dating
    Xu, Yihong
    Li, Chen
    Yu, Haiping
    Fang, Fengman
    Hou, Xiaolin
    Zhang, Chao
    Li, Xiaofei
    Xing, Shan
    Talanta, 2022, 240
  • [36] Ultra-trace determination of 90Sr, 137Cs, 238Pu, 239Pu, and 240Pu by triple quadruple collision/reaction cell-ICP-MS/MS: Establishing a baseline for global fallout in Qatar soil and sediments
    Amr, Mohamed A.
    Helal, Abdul-Fattah I.
    Al-Kinani, Athab T.
    Balakrishnan, Perumal
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 153 : 73 - 87
  • [37] Simultaneous determination of ultra-trace Au, Pt, Pd, Ru, Rh, Os and Ir in geochemical samples by KED-ICP-MS combined with Sb-Cu fire assay and microwave digestion
    Ni, Wenshan
    Zhang, Hongli
    Mao, Xiangju
    Liu, Lu
    Guo, Xiaorui
    Xiao, Fang
    Gao, Xiaofei
    MICROCHEMICAL JOURNAL, 2020, 158
  • [38] Matrix-matched multi-external standards combined internal standard calibration strategy for the simultaneous determination of ultra-trace Au, Pt and Pd in geochemical samples by LA-ICP-MS after lead fire assay preconcentration
    Ni, Wenshan
    Mao, Xiangju
    Zhang, Hongli
    Liu, Lu
    Guo, Xiaorui
    Zhang, Liping
    MICROCHEMICAL JOURNAL, 2021, 170