Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions

被引:47
|
作者
Hohl, C [1 ]
Schmidt, T [1 ]
Haage, P [1 ]
Honnef, D [1 ]
Blaum, M [1 ]
Staatz, G [1 ]
Guenther, RW [1 ]
机构
[1] Univ Technol Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
关键词
ultrasonography; harmonic imaging; pancreas; pancreatic carcinoma; pancreatitis;
D O I
10.1007/s00330-003-2191-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic sensitivity, specificity, and image quality of conventional B-mode US (BM) and phase-inversion tissue harmonic imaging (PTHI) regarding pancreatic pathology. In a prospective study, 107 patients, aged between 28 and 85 years, underwent US examinations of the pancreas with both BM and PTHI in a randomly chosen order. As diagnostic reference, either contrast-enhanced CT or MRI examinations of the upper abdomen were obtained in all patients. Sensitivity and specificity were evaluated using the Student's t test. Differences in overall image quality, lesion conspicuity, fluid-solid differentiation, and delineation of the pancreatic tail were analyzed using Wilcoxon's signed ranks test and Bowker's symmetry test. Sixteen of 107 examined patients (15%) were non-diagnostic and excluded due to technical limitations such as abdominal gas. A total of 60 pancreatic lesions (cysts, acute pancreatitis, dilatation of the pancreatic duct, calcifications, and solid tumors) were diagnosed by CT or MRI. Phase-inversion tissue harmonic imaging had a higher sensitivity of 70% (14 of 20) than BM (60%; 24 of 40) for the detection of pancreatic lesions; however, the difference was not statistically significant (p=0.46). In the assessment of lesions <1 cm of size, PTHI had a sensitivity of 70% and BM 46.7%, whereby the difference again was not statistically significant. Phase-inversion tissue harmonic imaging proved to be superior to BM regarding overall image quality (p<0.0001), lesion conspicuity (p=0.0045), and fluid-solid differentiation (p=0.0002), as well as the delineation of the pancreatic tail (p<0.0001). These differences were statistically significant. The statistically significant improvement of image quality with regards to lesion conspicuity, fluid-solid differentiation, and delineation of the pancreatic tail favors the use of PTHI when evaluating the pancreas with US. Sensitivity for pancreatic lesions is increased with PTHI in comparison with conventional sonography (BM), especially in lesions <1 cm in diameter, although the difference was not statistically significant.
引用
收藏
页码:1109 / 1117
页数:9
相关论文
共 50 条
  • [41] Noninvasive imaging techniques for the evaluation of aortic arch and carotid artery atherosclerosis in humans: A study with MRI and B-mode ultrasound
    Helft, G
    Worthley, SG
    Weinberger, J
    Zaman, AG
    Fayad, ZA
    Corti, R
    Fuster, V
    Badimon, JJ
    CIRCULATION, 2001, 104 (17) : 671 - 671
  • [42] The combination of pulsed acousto-optic imaging and B-mode diagnostic ultrasound for three-dimensional imaging in ex vivo biological tissue
    Sui, Lei
    Murray, Todd W.
    Roy, Ronald A.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2006, 2006, 6086
  • [43] Ultrasonic evaluation of quality attributes in live beef animals using real-time B-mode ultrasound imaging
    Amin, V
    Izquirdo, M
    Wilson, D
    Rouse, G
    Roberts, R
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 15A AND 15B, 1996, 15 : 1329 - 1334
  • [44] EVALUATION OF THE ACCURACY OF ARTICULAR CARTILAGE THICKNESS MEASUREMENT BY B-MODE ULTRASONOGRAPHY WITH CONVENTIONAL IMAGING AND REAL-TIME SPATIAL COMPOUND ULTRASONOGRAPHY IMAGING
    Ohashi, Satoru
    Ohnishi, Isao
    Matsumoto, Takuya
    Bessho, Masahiko
    Matsuyama, Juntaro
    Tobita, Kenji
    Kaneko, Masako
    Nakamura, Kozo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (02): : 324 - 334
  • [45] The Automated Breast Volume Scanner (ABVS): initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases
    Wojcinski, Sebastian
    Farrokh, Andre
    Hille, Ursula
    Wiskirchen, Jakub
    Gyapong, Samuel
    Soliman, Amr A.
    Degenhardt, Friedrich
    Hillemanns, Peter
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2011, 3 : 337 - 346
  • [46] Direct Comparison of Elastography Endoscopic Ultrasound Fine-Needle Aspiration and B-Mode Endoscopic Ultrasound Fine-Needle Aspiration in Diagnosing Solid Pancreatic Lesions
    Gheorghiu, Marcel
    Sparchez, Zeno
    Rusu, Ioana
    Bolboaca, Sorana D.
    Seicean, Radu
    Pojoga, Cristina
    Seicean, Andrada
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (03)
  • [47] Noninvasive evaluation of vaginal fibrosis following radiotherapy for gynecologic malignancies: A feasibility study with ultrasound B-mode and Nakagami parameter imaging
    Yang, Xiaofeng
    Rossi, Peter
    Bruner, Deborah Watkins
    Tridandapani, Srini
    Shelton, Joseph
    Liu, Tian
    MEDICAL PHYSICS, 2013, 40 (02)
  • [48] Comparison of B-mode and conventional Colour/Power Doppler ultrasound, contrast-enhanced Doppler ultrasound and spiral CT in the diagnosis of focal lesions of the liver: Results of a multicentre study
    Beissert, M
    Delorme, S
    Mutze, S
    Lees, WR
    Bahner, ML
    Filimonow, S
    Gillams, AR
    Zuna, I
    Bauer, A
    Jenett, M
    ULTRASCHALL IN DER MEDIZIN, 2002, 23 (04): : 245 - 250
  • [49] The quantative evaluation of contrast harmonic imaging in the differential diagnosis of hepatic tumors and the therapeutic effect of hepatocellular carcinoma (HCC) with B-mode second harmonic ultrasonography (US)
    Hori, N
    Sakai, M
    Ohta, M
    JOURNAL OF HEPATOLOGY, 2002, 36 : 269 - 269
  • [50] The quantitative evaluation of contrast harmonic imaging in the differential diagnosis of hepatic tumors and the therapeutic effect of hepatocellular carcinoma (HCC) with B-mode second harmonic ultrasonography.
    Hori, N
    Sakai, M
    Ohta, M
    HEPATOLOGY, 2001, 34 (04) : 678A - 678A