Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions

被引:47
|
作者
Hohl, C [1 ]
Schmidt, T [1 ]
Haage, P [1 ]
Honnef, D [1 ]
Blaum, M [1 ]
Staatz, G [1 ]
Guenther, RW [1 ]
机构
[1] Univ Technol Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
关键词
ultrasonography; harmonic imaging; pancreas; pancreatic carcinoma; pancreatitis;
D O I
10.1007/s00330-003-2191-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic sensitivity, specificity, and image quality of conventional B-mode US (BM) and phase-inversion tissue harmonic imaging (PTHI) regarding pancreatic pathology. In a prospective study, 107 patients, aged between 28 and 85 years, underwent US examinations of the pancreas with both BM and PTHI in a randomly chosen order. As diagnostic reference, either contrast-enhanced CT or MRI examinations of the upper abdomen were obtained in all patients. Sensitivity and specificity were evaluated using the Student's t test. Differences in overall image quality, lesion conspicuity, fluid-solid differentiation, and delineation of the pancreatic tail were analyzed using Wilcoxon's signed ranks test and Bowker's symmetry test. Sixteen of 107 examined patients (15%) were non-diagnostic and excluded due to technical limitations such as abdominal gas. A total of 60 pancreatic lesions (cysts, acute pancreatitis, dilatation of the pancreatic duct, calcifications, and solid tumors) were diagnosed by CT or MRI. Phase-inversion tissue harmonic imaging had a higher sensitivity of 70% (14 of 20) than BM (60%; 24 of 40) for the detection of pancreatic lesions; however, the difference was not statistically significant (p=0.46). In the assessment of lesions <1 cm of size, PTHI had a sensitivity of 70% and BM 46.7%, whereby the difference again was not statistically significant. Phase-inversion tissue harmonic imaging proved to be superior to BM regarding overall image quality (p<0.0001), lesion conspicuity (p=0.0045), and fluid-solid differentiation (p=0.0002), as well as the delineation of the pancreatic tail (p<0.0001). These differences were statistically significant. The statistically significant improvement of image quality with regards to lesion conspicuity, fluid-solid differentiation, and delineation of the pancreatic tail favors the use of PTHI when evaluating the pancreas with US. Sensitivity for pancreatic lesions is increased with PTHI in comparison with conventional sonography (BM), especially in lesions <1 cm in diameter, although the difference was not statistically significant.
引用
收藏
页码:1109 / 1117
页数:9
相关论文
共 50 条
  • [1] Phase-inversion tissue harmonic imaging compared with conventional B-mode ultrasound in the evaluation of pancreatic lesions
    Christian Hohl
    Thorsten Schmidt
    Patrick Haage
    Dagmar Honnef
    Marcus Blaum
    Gundula Staatz
    Rolf W. Guenther
    European Radiology, 2004, 14 : 1109 - 1117
  • [2] Phase-inversion tissue harmonic imaging compared to fundamental B-mode ultrasound in the evaluation of the pathology of large and small bowel
    Schmidt, T
    Hohl, C
    Haage, P
    Honnef, D
    Mahnken, AH
    Krombach, G
    Piroth, W
    Günther, RW
    EUROPEAN RADIOLOGY, 2005, 15 (09) : 2021 - 2030
  • [3] Phase-inversion tissue harmonic imaging compared to fundamental B-mode ultrasound in the evaluation of the pathology of large and small bowel
    T. Schmidt
    C. Hohl
    P. Haage
    D. Honnef
    A. H. Mahnken
    G. Krombach
    W. Piroth
    R. W. Günther
    European Radiology, 2005, 15 : 2021 - 2030
  • [4] Diagnostic accuracy of phase-inversion tissue harmonic imaging versus fundamental B-mode sonography in the evaluation of focal lesions of the kidney
    Schmidt, T
    Hohl, C
    Haage, P
    Blaum, M
    Honnef, D
    Weiss, C
    Staatz, G
    Günther, RW
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (06) : 1639 - 1647
  • [5] EVALUATION OF ATHEROSCLEROSIS WITH B-MODE ULTRASOUND IMAGING
    PIGNOLI, P
    LONGO, T
    JOURNAL OF NUCLEAR MEDICINE AND ALLIED SCIENCES, 1988, 32 (03): : 166 - 173
  • [6] Parameters of cerebral perfusion in phase-inversion harmonic imaging (PIHI) ultrasound examinations
    Eyding, J
    Krogias, C
    Wilkening, W
    Meves, S
    Ermert, H
    Postert, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (10): : 1379 - 1385
  • [7] Comparison of contrast harmonic imaging in B-Mode with stimulated acoustic emission, conventional B-Mode US and spiral CT in the detection of liver lesions
    Beissert, M
    Jenett, M
    Keberle, M
    Kessler, C
    Klein, D
    Beer, M
    Hahn, D
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (04): : 361 - 366
  • [8] Improved ultrasound sensitivity in detecting focal liver lesions by B-mode harmonic imaging and contrast enhancement
    Campani, R
    Calliada, F
    Bottinelli, O
    Bozzini, A
    Bianchi, S
    Nervetti, S
    RADIOLOGY, 1998, 209P : 232 - 232
  • [9] Ultrasonographic evaluation of focal hepatic lesions: Comparison of pulse inversion harmonic, tissue harmonic, and conventional imaging techniques
    Jang, HJ
    Lim, HK
    Lee, WJ
    Kim, SH
    Kim, KA
    Kim, EY
    JOURNAL OF ULTRASOUND IN MEDICINE, 2000, 19 (05) : 293 - 299
  • [10] Image quality and detection of pathology by ultrasound: Comparison of B-mode ultrasound with photopic imaging and tissue harmonic imaging alone and in combination
    Fischer, T
    Filimonow, S
    Taupitz, M
    Petersein, J
    Beyersdorff, D
    Bollow, M
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1313 - 1317