Influence of Rectangular Ribs on Exergetic Performance in a Triangular Duct Solar Air Heater

被引:20
|
作者
Nidhul, Kottayat [1 ]
Kumar, Sachin [1 ]
Yadav, Ajay Kumar [1 ]
Anish, S. [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Adv Heat Transfer Lab, Surathkal 575025, India
关键词
solar air heater; triangular duct; artificial roughness; rectangular rib; thermal efficiency; entropy generation; exergetic efficiency; energy efficiency; energy systems; extended surfaces; fins; forced convection; heat exchangers; heat transfer enhancement; FRICTION FACTOR CORRELATIONS; 2ND LAW OPTIMIZATION; FORCED-CONVECTION; ARTIFICIAL ROUGHNESS; FLOW; ENERGY; PLATE; OPERATION; COLLECTOR; COEFFICIENT;
D O I
10.1115/1.4046057
中图分类号
O414.1 [热力学];
学科分类号
摘要
Several artificial roughness (ribs) configurations have been used in flat plate solar air heaters (SAH) in recent years to improve their overall performance. In the present work, energy and exergy analyses of rectangular ribs in a triangular duct SAH for varying relative rib heights (e/D = 0.02-0.04), relative rib pitches (P/e = 5-15), and rib aspect ratios (e/w = 0.5-4) are evaluated and compared with smooth SAH. The analysis reveals that the entropy generated due to heat transfer is lower for the ribbed triangular duct compared to the smooth duct. It is also observed that the width of the rib plays a crucial role in minimizing heat losses to the environment. A maximum reduction of 43% and 62% in exergy losses to the environment and exergy losses due to heat transfer to the fluid is achieved, respectively, with a rib aspect ratio (e/w) of 4 compared to the smooth plate. It is found that in contrast to the smooth plate, ribs beneath the absorber plate effectively improves thermal and exergetic efficiency. Maximum enhancement of 36% and 17% is obtained in exergetic efficiency (eta (ex)) and thermal efficiency (eta (th)), respectively, for e/w = 4, P/e = 10 and e/D = 0.04. Results also show the superiority of the ribbed triangular duct over the ribbed rectangular duct for an application requiring compact SAH with a higher flowrate.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Thermo-Hydraulic Characteristics Evaluation of a Triangular Solar Air Heater Duct Having Transverse Ribs With Gaps: An Experimental Study
    Mahanand, Yadaba
    Senapati, Jnana Ranjan
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (04):
  • [22] Analysis of exergetic performance for a solar air heater with metal foam fins
    Farhan, Ammar A.
    Obaid, Zain Alabdeen H.
    Hussien, Sally Q.
    HEAT TRANSFER, 2020, 49 (05) : 3190 - 3204
  • [23] Exergetic performance evaluation of a single pass baffled solar air heater
    Sabzpooshani, M.
    Mohammadi, K.
    Khorasanizadeh, H.
    Energy, 2014, 64 : 697 - 706
  • [24] Exergetic performance evaluation of a single pass baffled solar air heater
    Sabzpooshani, M.
    Mohammadi, K.
    Khorasanizadeh, H.
    Energy, 2014, 64 : 697 - 706
  • [25] Exergetic performance evaluation of a single pass baffled solar air heater
    Sabzpooshani, M.
    Mohammadi, K.
    Khorasanizadeh, H.
    ENERGY, 2014, 64 : 697 - 706
  • [26] Performance study of solar air heater duct with gap in V-rib with symmetrical gap and staggered ribs
    Sumer Singh Patel
    Atul Lanjewar
    Heat and Mass Transfer, 2019, 55 : 2517 - 2532
  • [27] Performance study of solar air heater duct with gap in V-rib with symmetrical gap and staggered ribs
    Patel, Sumer Singh
    Lanjewar, Atul
    HEAT AND MASS TRANSFER, 2019, 55 (09) : 2517 - 2532
  • [28] Performance prediction of solar air heater having roughened duct provided with transverse and inclined ribs as artificial roughness
    Varun
    Patnaik, Amar
    Saini, R. P.
    Singal, S. K.
    Siddhartha
    RENEWABLE ENERGY, 2009, 34 (12) : 2914 - 2922
  • [29] Optimization of artificial roughness parameters in a solar air heater duct roughened with hybrid ribs
    Gill, Raminder Singh
    Hans, Vishavjeet Singh
    Singh, Rupinder Pal
    APPLIED THERMAL ENGINEERING, 2021, 191
  • [30] Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs
    Alam, Tabish
    Kim, Man-Hoe
    APPLIED THERMAL ENGINEERING, 2017, 126 : 458 - 469