Proficiency Testing on Gross Alpha/Beta Measurements in Drinking Water: Lessons Learnt

被引:0
|
作者
Radulescu, I. [1 ]
Calin, M. R. [1 ]
Stochioiu, A. [1 ]
机构
[1] Horia Hulubei Natl Inst Phys & Nucl Engn, IFIN HH, Reactorului Str 30,POB MG 6, RO-077125 Bucharest, Romania
关键词
Gross alpha; beta analysis; Drinking water; Relative bias; Uncertainties; Proficiency test;
D O I
10.1007/s12161-021-02007-2
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Gross alpha-beta measurement is a worldwide applied technique to determine activity concentration in drinking water. Laboratories have implemented standard methods where standard sources measurements and routine methods are applied to achieve good analytical results. Proficiency testing is among the most used methods to assess the accuracy of the analytical data produced by laboratories, as this also represents a requirement for laboratories which have ISO 17025 and a quality assurance system implemented. The results presented in this paper show the performance of two laboratories for proficiency tests organized by IAEA, to which SALMROM laboratory and Personal Dosimetry Monitoring Laboratory (LDPM) have participated in 3 years. The feedback from the final reports from IAEA reports demonstrates the performance of the laboratories where 17 out of 18 results pass the acceptance criteria. Only one reported result has a warning which means that it did not pass all acceptance criteria. The results served as a basis to improve the laboratory analysis and to optimize accuracy measurements. The overall results of the PTs point out the reliability and traceability of the systems used for drinking water measurements.
引用
收藏
页码:1695 / 1703
页数:9
相关论文
共 50 条
  • [21] Results of a European interlaboratory comparison on gross alpha/beta activity determination in drinking water
    Viktor Jobbágy
    Jana Merešová
    Edmond Dupuis
    Pieter Kwakman
    Timotheos Altzitzoglou
    Andrej Rožkov
    Mikael Hult
    Håkan Emteborg
    Uwe Wätjen
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 306 : 325 - 331
  • [22] Results of a European interlaboratory comparison on gross alpha/beta activity determination in drinking water
    Jobbagy, Viktor
    Meresova, Jana
    Dupuis, Edmond
    Kwakman, Pieter
    Altzitzoglou, Timotheos
    Rozkov, Andrej
    Hult, Mikael
    Emteborg, Hakan
    Watjen, Uwe
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 306 (01) : 325 - 331
  • [23] Characterization of an array of gas-flow proportional counters for determination of gross alpha and gross beta in drinking water
    Aviv, O.
    Daniely, E.
    Barazani, Y.
    Baziza, T.
    Koch, J.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (06)
  • [24] DETECTION LIMITS, ACCURACY AND PRECISION OF GROSS ALPHA AND BETA MEASUREMENTS ON WATER - NUCL
    BARATTA, EJ
    KNOWLES, FE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1970, (FEB): : 50 - &
  • [25] An application of LSC method for the measurement of gross alpha and beta activities in spiked water and drinking water samples
    Cakal, Gaye Ozgur
    Guven, Rufi Yet
    Yucel, Haluk
    NUKLEONIKA, 2015, 60 (03) : 637 - 642
  • [26] STATISTICAL LIMITS OF ACCURACY AND PRECISION OF GROSS ALPHA AND BETA RADIOACTIVITY MEASUREMENTS IN WATER
    BARATTA, EJ
    KNOWLES, FE
    RADIOLOGICAL HEALTH DATA AND REPORTS, 1971, 12 (04): : 195 - &
  • [28] Determination of natural radioactivity by gross alpha and beta measurements in ground water samples
    Turhan, S.
    Ozcitak, E.
    Taskin, H.
    Varinlioglu, A.
    WATER RESEARCH, 2013, 47 (09) : 3103 - 3108
  • [29] Establishing a proficiency testing scheme for drinking water radiochemistry
    Brookman, Brian
    NUCLEAR PROFICIENCY TESTING, 2008, 1036 : 114 - 120
  • [30] Radioactivity Measurement Method for Environmental Monitoring Gross Alpha/beta Activities in Drinking Water in Turkey
    Kahraman, Gulten
    Asian, Nazife
    Sahin, Mihriban
    Yuksek, Simay
    ACTA CHIMICA SLOVENICA, 2015, 62 (03) : 595 - 604