摘要
Objective: To compare axial and coronal Fast Spin-Echo fat-suppressed T2-weighted sequences with three-dimensional (3D) maximum intensity projection (MIP) images in patients with suspected pancreaticobiliary obstruction. Material and methods: MR cholangiopancreatography (MRCP) was performed in 108 consecutive patients with a non-breath-hold, fat-suppressed, 2D, heavily T2-weighted fast spin-echo sequence in coronal plane. Axial T1- and T2-weighted images were previously obtained. In addition. 3D reconstructions of the coronal images were analysed separately by using a MIP algorithm. Both two-dimensional (2D) (axial and coronal) and 3D MIP images were separately evaluated by two readers in conference and their results were compared with that of endoscopic retrograde cholangiopancreatography, percutaneous trans-hepatic cholangiography, surgery and:or imaging follow-up. Statistical analysis of 2D and 3D MRCP images in diagnosing the level and probable cause of pancreaticobiliary obstruction were separately calculated. Results: 106/108 of MRCP examinations were judged diagnostic by the two reviewers for adequacy of visualisation of the biliary and pancreatic ducts, Sensitivity, specificity, positive predictive value, negative predictive value and global diagnostic accuracy of 2D (axial and coronal) and 3D MRCP images in diagnosing the pancreaticobiliary obstruction were 94 and 57%, 95 and 93%, 97 and 92%, 91 and 60%, 94 and 72%, respectively. Conclusion: Our results do indicate a higher global accuracy for axial and coronal fast Spin-Echo fat-suppressed T2-weighted sequences versus 3D MIP images in diagnosis of the level and probable cause of pancreaticobiliary obstruction and stress the limitations of 3D images in depiction of small intraductal pathology such as calculi and biliary neoplastic lesions. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 181
页数:11
相关论文
共 50 条
  • [21] Comparison of fat-suppressed T2-weighted fast spin-echo sequence and modified STIR sequence in the evaluation of the rotator cuff tendon.
    Kijowski, R
    Farber, JM
    Medina, J
    Morrison, W
    Ying, J
    Buckwalter, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) : 371 - 378
  • [22] T2-weighted fast spin-echo MR imaging of liver.
    Mirowitz, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 263 - 264
  • [23] THE PELVIS - T2-WEIGHTED FAST SPIN-ECHO MR-IMAGING
    NGHIEM, HV
    HERFKENS, RJ
    FRANCIS, IR
    SOMMER, FG
    JEFFREY, RB
    LI, KCP
    STEINER, RM
    GLOVER, GH
    RADIOLOGY, 1992, 185 (01) : 213 - 217
  • [24] Is there an Added Value of T1-Weighted Contrast-Enhanced Fat-suppressed Spin-Echo MR Sequences Compared to STIR Sequences in MRI of the Foot and Ankle?
    Veronika Zubler
    Marco Zanetti
    Tobias J. Dietrich
    Norman Espinosa
    Christian W. Pfirrmann
    Nadja Mamisch-Saupe
    European Radiology, 2017, 27 : 3452 - 3459
  • [25] Is there an Added Value of T1-Weighted Contrast-Enhanced Fat-suppressed Spin-Echo MR Sequences Compared to STIR Sequences in MRI of the Foot and Ankle?
    Zubler, Veronika
    Zanetti, Marco
    Dietrich, Tobias J.
    Espinosa, Norman
    Pfirrmann, Christian W.
    Mamisch-Saupe, Nadja
    EUROPEAN RADIOLOGY, 2017, 27 (08) : 3452 - 3459
  • [26] Comparison of single-echo T2-weighted fast spin-echo and conventional spin-echo MR sequences - In the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Banco, A
    Miraglia, R
    Nicastro, T
    Lagalla, R
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 (04): : 471 - 476
  • [27] FAST MRI WITH T2-WEIGHTED SPIN-ECHO SEQUENCES BY VARYING THE FLIP ANGLE
    SCHUBEUS, P
    SANDER, B
    SCHORNER, W
    DEIMLING, M
    TOSCH, U
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (03): : 272 - 276
  • [28] PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN
    SCHWARTZ, LH
    SELTZER, SE
    TEMPANY, CMC
    SILVERMAN, SG
    PIWNICAWORMS, DR
    ADAMS, DF
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    RADIOLOGY, 1993, 189 (02) : 411 - 416
  • [29] Gradient-echo versus fat-suppressed fast spin-echo MR imaging of rotator cuff tears
    Sahin-Akyar, G
    Miller, TT
    Staron, RB
    McCarthy, DM
    Feldman, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 223 - 227
  • [30] COMPARISON OF T2-WEIGHTED SPIN-ECHO AND FAST SPIN-ECHO TECHNIQUES IN THE EVALUATION OF MYELINATION
    PRENGER, EC
    BECKETT, WW
    KOLLIAS, SS
    BALL, WS
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02): : 179 - 184