Evaluation of a commercial three-dimensional electron beam treatment planning system

被引:20
|
作者
Ding, GX
Cygler, JE
Zhang, GG
Yu, MK
机构
[1] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Surrey, BC V3V 1Z2, Canada
[2] Ottawa Reg Canc Ctr, Dept Phys Med, Ottawa, ON K1Y 4K7, Canada
[3] Natl Res Council Canada, Ottawa, ON, Canada
关键词
electron beam; treatment planning; inhomogeneous phantom;
D O I
10.1118/1.598795
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated a commercial three-dimensional (3D) electron beam treatment planning system (CADPLAN V.2.7.9) using both experimentally measured and Monte Carlo calculated dose distributions to compare with those predicted by CADPLAN calculations. Tests were carried out at various field sizes and electron beam energies from 6 to 20 MeV. For a homogeneous water phantom the agreement between measured and CADPLAN calculated dose distributions is very good except at the phantom surface. CADPLAN is able to predict hot and cold spots caused by a simple 3D inhomogeneity but unable to predict dose distributions for a more complex geometry where CADPLAN underestimates dose changes caused by inhomogeneity. We discussed possible causes for the inaccuracy in the CADPLAN dose calculations. In addition, we have tested CADPLAN treatment monitor unit and electron cut-out factor calculations and found that CADPLAN predictions generally agree with manual calculations. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00412-5].
引用
收藏
页码:2571 / 2580
页数:10
相关论文
共 50 条
  • [21] Three-dimensional treatment planning for prosthetic rehabilitation
    Besimo, CE
    Rohner, HP
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (01) : 81 - 87
  • [22] An interactive beam-weight optimization tool for three-dimensional radiotherapy treatment planning
    Burba, S
    Gardey, K
    Nadobny, J
    Stalling, D
    Seebass, M
    Beier, J
    Wust, P
    Budach, V
    Felix, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 337 - 337
  • [23] Three-dimensional design in electron-beam lithography
    Aristov, VV
    Dubonos, SV
    Dyachenko, RY
    Gaifullin, BN
    Matveev, VN
    Raith, H
    Svintsov, AA
    Zaitsev, SI
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1995, 13 (06): : 2526 - 2528
  • [24] Three-dimensional additive electron-beam lithography
    Koops, HWP
    Weber, M
    Schossler, C
    Kaja, A
    METAL/NONMETAL MICROSYSTEMS: PHYSICS, TECHNOLOGY, AND APPLICATIONS, 1996, 2780 : 388 - 395
  • [25] Three-dimensional model of electron beam generated plasma
    Rauf, Shahid
    Balakrishna, Ajit
    Agarwal, Ankur
    Dorf, Leonid
    Collins, Kenneth
    Boris, David R.
    Walton, Scott G.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2017, 26 (06):
  • [26] Three-dimensional simulation study on the electron beam lithography
    Song, Hui-Ying
    Yang, Rui
    Zhao, Zhen-Yu
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2010, 38 (03): : 617 - 619
  • [27] Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning
    Cygler, JE
    Daskalov, GM
    Chan, GH
    Ding, GX
    MEDICAL PHYSICS, 2004, 31 (01) : 142 - 153
  • [28] Evaluation of electron beam tomographic coronary arteriography with three-dimensional reconstruction in healthy subjects
    Lu, B
    Dai, RP
    Bai, H
    He, S
    Jing, BL
    Zhuang, N
    Gao, RL
    Yang, YJ
    Chen, JL
    Budoff, MJ
    ANGIOLOGY, 2000, 51 (11) : 895 - 904
  • [29] Evaluation of a Pencil Beam Scanning Proton Dose Model for a Commercial Treatment Planning System
    Patel, D.
    Poenisch, F.
    Sahoo, N.
    Zhu, X.
    Gillin, M.
    Janson, M.
    Mohan, R.
    Titt, U.
    MEDICAL PHYSICS, 2018, 45 (06) : E261 - E261
  • [30] Development of a three-dimensional treatment planning system based on computed tomographic data
    Troulis, MJ
    Everett, R
    Seldin, EB
    Kikinis, R
    Kaban, LB
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (04) : 349 - 357