Evaluation of a commercial three-dimensional electron beam treatment planning system

被引:20
|
作者
Ding, GX
Cygler, JE
Zhang, GG
Yu, MK
机构
[1] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Surrey, BC V3V 1Z2, Canada
[2] Ottawa Reg Canc Ctr, Dept Phys Med, Ottawa, ON K1Y 4K7, Canada
[3] Natl Res Council Canada, Ottawa, ON, Canada
关键词
electron beam; treatment planning; inhomogeneous phantom;
D O I
10.1118/1.598795
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We evaluated a commercial three-dimensional (3D) electron beam treatment planning system (CADPLAN V.2.7.9) using both experimentally measured and Monte Carlo calculated dose distributions to compare with those predicted by CADPLAN calculations. Tests were carried out at various field sizes and electron beam energies from 6 to 20 MeV. For a homogeneous water phantom the agreement between measured and CADPLAN calculated dose distributions is very good except at the phantom surface. CADPLAN is able to predict hot and cold spots caused by a simple 3D inhomogeneity but unable to predict dose distributions for a more complex geometry where CADPLAN underestimates dose changes caused by inhomogeneity. We discussed possible causes for the inaccuracy in the CADPLAN dose calculations. In addition, we have tested CADPLAN treatment monitor unit and electron cut-out factor calculations and found that CADPLAN predictions generally agree with manual calculations. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00412-5].
引用
收藏
页码:2571 / 2580
页数:10
相关论文
共 50 条
  • [1] Evaluation of a commercial three-dimensional electron pencil beam algorithm
    S. Margaret Mercy Healthcare Centers, Hammond, IN 46320, United States
    不详
    MED. PHYS., 1 (91-101):
  • [2] Evaluation of a commercial three-dimensional electron pencil beam algorithm
    MullerRunkel, R
    Cho, SH
    MEDICAL PHYSICS, 1997, 24 (01) : 91 - 101
  • [3] Dosimetric evaluation of a three-dimensional treatment planning system
    Murugan, Appasamy
    Valas, Xavier Sidonia
    Thayalan, Kuppusamy
    Ramasubramanian, Velayudham
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (01) : 15 - 21
  • [4] Evaluation of a Monte Carlo Based Commercial Electron Beam Treatment Planning System
    Al Kafi, M.
    Moftah, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S844 - S844
  • [5] Three-Dimensional Virtual Treatment Planning: Presurgical Evaluation
    Farronato, Giampietro
    Galbiati, Guido
    Esposito, Luca
    Mortellaro, Carmen
    Zanoni, Federica
    Maspero, Cinzia
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (05) : E433 - E437
  • [6] Implementations of the generalised Gaussian pencil beam algorithm for three-dimensional electron beam dose planning
    Hyodynmaa, Simo
    Publications - Technical Research Centre of Finland, 1991, (74): : 1 - 96
  • [7] A beam model for three-dimensional radiotherapy planning
    Redpath, AT
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (816): : 1356 - 1363
  • [8] Three-dimensional optimization of treatment planning for gamma unit treatment system
    Shu, HZ
    Yan, YL
    Luo, LM
    Bao, XD
    MEDICAL PHYSICS, 1998, 25 (12) : 2352 - 2357
  • [9] A three-dimensional treatment planning system for interstitial hyperthermia and brachytherapy
    DeBree, J
    Kotte, ANTJ
    VanderKoijk, JF
    Lagendijk, JJW
    QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 96 - 98
  • [10] Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
    Francescon, P
    Cavedon, C
    Reccanello, S
    Cora, S
    MEDICAL PHYSICS, 2000, 27 (07) : 1579 - 1587