Impact of Stirring on the Luminescent Dissolved Oxygen Sensor

被引:1
|
作者
Colt, John [1 ]
机构
[1] NOAA, Natl Marine Fisheries Serv, NW Fisheries Sci Ctr, Seattle, WA 98112 USA
关键词
D O I
10.1080/15222055.2014.893474
中图分类号
S9 [水产、渔业];
学科分类号
0908 ;
摘要
The impact of stirring on the response of the field YSI ProODO luminescence dissolved oxygen sensor was measured in a 300-mL biological oxygen demand (BOD) test bottle with a magnetic stirrer either on or off. With a water sample from a fish transport experiment, the dissolved oxygen dropped by 2-3 mg/L when the magnetic stirrer was turned off for 11 min. The initial rate of dissolved oxygen decline ranged from -0.39 to -1.04 mg/L per min for this water. The dissolved oxygen returned to a value projected from the oxygen uptake rate when the stirrer was turned on. A much smaller impact was observed for 18.2 M Omega high-purity water (mean: -0.11 mg/L). Acid-washing the BOD bottle/stir bar and cleaning the sensor cap reduced the decrease to -0.08 mg/L. Based on t-tests between pairs of stirring-on and stirring-off results, the lack of stirring had a significant effect on measured dissolved oxygen. The source of this effect and its potential impact on the accuracy of the optical probe under typical operating conditions remain to be determined.
引用
收藏
页码:242 / 244
页数:3
相关论文
共 50 条
  • [41] Fault detection of dissolved oxygen sensor in wastewater treatment plants
    Li, Xuemeng
    Chai, Wei
    Liu, Tong
    Qiao, Junfei
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 225 - 230
  • [42] Soft-sensor Software Design of Dissolved Oxygen in Aquaculture
    Wang Wei
    Deng Changhui
    Li Xiangjun
    Gu Jun
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 5413 - 5417
  • [43] Diatom frustules based dissolved oxygen sensor with superhydrophobic surface
    Zhou, Dongyan
    Cai, Shaoyong
    Sun, Haoyang
    Zhong, Gansheng
    Zhang, He
    Sun, Dazhi
    Su, Fengyu
    Deng, Mengyu
    Tian, Yanqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 371
  • [44] An optical sensor for monitoring of dissolved oxygen based on phase detection
    Feng, Weiwei
    Zhou, Na
    Chen, Lingxin
    Li, Bowei
    JOURNAL OF OPTICS, 2013, 15 (05)
  • [45] Micromachined dissolved oxygen sensor based on solid polymer electrolyte
    Wang, Peng
    Liu, Yi
    Abruna, Hector D.
    Spector, Jason A.
    Olbricht, William L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01): : 145 - 151
  • [46] Microfabirated Clark-type sensor for measuing dissolved oxygen
    Park, Jungil
    Chang, Jong-hyeon
    Choi, Myungki
    Pak, James Jungho
    Lee, Dong-Young
    Pak, Youngmi Kim
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 1412 - 1415
  • [47] DETERMINATION OF MICROCONCENTRATIONS OF DISSOLVED IN WATER OXYGEN BY MEANS OF AN ELECTROCHEMICAL SENSOR
    FLIS, BI
    ALESKOVS.VB
    ROIF, GI
    MUKHIN, NN
    ZHURNAL ANALITICHESKOI KHIMII, 1972, 27 (04): : 736 - +
  • [48] A hand-held optical sensor for dissolved oxygen measurement
    Xiao, D
    Mo, YY
    Choi, MMF
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (06) : 862 - 867
  • [49] POTENTIOMETRIC DISSOLVED-OXYGEN SENSOR USING PROTON CONDUCTORS
    KUWATA, S
    MIURA, N
    YAMAZOE, N
    NIPPON KAGAKU KAISHI, 1987, (08) : 1518 - 1523
  • [50] An improved Clark-type galvanic sensor for dissolved oxygen
    Nei, L
    Compton, RG
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (02) : 83 - 87