Establishment of CZT pixellated radiation detection system and pulse-height correction

被引:1
|
作者
Shen, Min [1 ,2 ]
Xiao, Sha Li [2 ]
Li, Miao [3 ]
机构
[1] Chongqing Radio & TV Univ, Chongqing 400052, Peoples R China
[2] Chongqing Univ, Key Lab Optoelect Technol & Syst, Educ Minist China, Chongqing 400030, Peoples R China
[3] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing 400065, Peoples R China
来源
OPTIK | 2018年 / 158卷
基金
中国国家自然科学基金;
关键词
CdZnTe (CZT); Semiconductor detector; Pixel array; Pulse-height correction; Energy resolution;
D O I
10.1016/j.ijleo.2017.12.143
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
11 x 11 x 3 mm(3) and 4 x 4 pixel array CdZnTe (CZT) detector system based on the principle of CZT pixel array detector and correction algorithm has been established. The leakage current of CZT pixellated crystal is tested and analyzed. The pulse amplitude spectrum of the CZT detector has been measured using Cs-137 662 keV Gamma source. The average energy resolution of pixellated detector system is 3.3% and full energy peak FWHM is 21.85 keV.The corrected algorithm of pulse-height is applied for improving spectroscopy response. The average energy resolution of corner pixels has been improved. The best energy resolution of pixels is 2.5% after correction. The energy resolution of the 4 x 4 pixellated CZT detector system is excellent. The spectrum performance of edge pixels is obvious improved by pulse height correction. The resolution of edge pixels is improved efficiently. (C) 2017 Elsevier GmbH. All rights reserved.
引用
收藏
页码:1220 / 1226
页数:7
相关论文
共 50 条
  • [21] RFX X-RAY PULSE-HEIGHT ANALYSIS SYSTEM
    CARRARO, L
    VALISA, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2801 - 2803
  • [22] IMPROVED SYSTEM OF DOT ON FILM RECORDS FOR PULSE-HEIGHT ANALYSIS
    CHOUDHURY, SS
    BANERJEE, BM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (12): : 1080 - 1080
  • [23] AN EASY-TO-OPERATE PORTABLE PULSE-HEIGHT ANALYSIS SYSTEM FOR AREA MONITORING WITH TEPC IN RADIATION PROTECTION
    KUNZ, A
    PIHET, P
    AREND, E
    MENZEL, HG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 696 - 701
  • [24] THEORETICAL PULSE-HEIGHT DISTRIBUTION OF OPTICAL CERENKOV RADIATION FROM LARGE EAS
    PATHAK, KM
    TALUKDAR, K
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1981, 19 (07) : 642 - 645
  • [25] A FAST PUNCHED-CARD READOUT SYSTEM FOR PULSE-HEIGHT ANALYZERS
    EULER, BA
    PHELPS, PL
    COVELL, DF
    NUCLEAR INSTRUMENTS & METHODS, 1965, 34 (03): : 266 - &
  • [26] SYSTEM FOR ELIMINATING RANDOM EVENTS FROM PULSE-HEIGHT COINCIDENCE SPECTRA
    BEATTIE, RJD
    BYRNE, J
    NUCLEAR INSTRUMENTS & METHODS, 1971, 95 (02): : 373 - &
  • [27] MEMPHIS 2000 - A MODULAR EXPERIMENT MULTIPARAMETER PULSE-HEIGHT INSTRUMENTATION SYSTEM
    KAYSER, FJ
    STEVENS, W
    STOFF, H
    WATZLAWIK, K
    KARNADI, M
    GAST, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (02) : 176 - 180
  • [28] Simple system for dual-parameter multichannel pulse-height analysis
    Kusakabe, T
    Taniguchi, H
    Norizawa, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1996, 35 (11): : 5882 - 5883
  • [29] AUTOMATIC DEAD-TIME CORRECTION IN AI-100 PULSE-HEIGHT ANALYZER
    VINOKURO.VA
    VESNOVSK.SP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (05): : 1154 - &
  • [30] AUTOMATIC CORRECTION OF PULSE-HEIGHT SHIFTS DUE TO QUENCHING IN LIQUID-SCINTILLATION COUNTING
    BUDD, AL
    STEPHENS, WD
    MILLER, JA
    APPLIED SPECTROSCOPY, 1968, 22 (04) : 371 - &