Establishment of CZT pixellated radiation detection system and pulse-height correction

被引:1
|
作者
Shen, Min [1 ,2 ]
Xiao, Sha Li [2 ]
Li, Miao [3 ]
机构
[1] Chongqing Radio & TV Univ, Chongqing 400052, Peoples R China
[2] Chongqing Univ, Key Lab Optoelect Technol & Syst, Educ Minist China, Chongqing 400030, Peoples R China
[3] Chongqing Univ Posts & Telecommun, Coll Optoelect Engn, Chongqing 400065, Peoples R China
来源
OPTIK | 2018年 / 158卷
基金
中国国家自然科学基金;
关键词
CdZnTe (CZT); Semiconductor detector; Pixel array; Pulse-height correction; Energy resolution;
D O I
10.1016/j.ijleo.2017.12.143
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
11 x 11 x 3 mm(3) and 4 x 4 pixel array CdZnTe (CZT) detector system based on the principle of CZT pixel array detector and correction algorithm has been established. The leakage current of CZT pixellated crystal is tested and analyzed. The pulse amplitude spectrum of the CZT detector has been measured using Cs-137 662 keV Gamma source. The average energy resolution of pixellated detector system is 3.3% and full energy peak FWHM is 21.85 keV.The corrected algorithm of pulse-height is applied for improving spectroscopy response. The average energy resolution of corner pixels has been improved. The best energy resolution of pixels is 2.5% after correction. The energy resolution of the 4 x 4 pixellated CZT detector system is excellent. The spectrum performance of edge pixels is obvious improved by pulse height correction. The resolution of edge pixels is improved efficiently. (C) 2017 Elsevier GmbH. All rights reserved.
引用
收藏
页码:1220 / 1226
页数:7
相关论文
共 50 条
  • [1] Establishment of CZT pixellated radiation detection system and realization of its amplitude correction
    Li, Miao
    Xiao, Sha-Li
    Wang, Xi
    Chen, Yu-Xiao
    Cao, Yu-Lin
    Nie, Ling
    Zhang, Liu-Qiang
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2011, 22 (09): : 1277 - 1282
  • [2] Array of virtual Frisch-grid CZT detectors with common cathode readout and pulse-height correction
    Bolotnikov, A. E.
    Camarda, G. S.
    Cui, Y.
    Egarievwe, S. U.
    Fochuk, P. M.
    Fuerstnau, M.
    Gul, R.
    Hossain, A.
    Jones, F.
    Kim, K.
    Kopach, O. V.
    Taggart, R.
    Yang, G.
    Ye, Z.
    Xu, L.
    James, R. B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XII, 2010, 7805
  • [3] RADIATION SPECTROSCOPY BY DIGITAL PULSE-HEIGHT ANALYSIS
    ARCOS, JML
    GARCIATORANO, E
    OLMOS, P
    MARIN, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 251 - 253
  • [4] PULSE-HEIGHT ANALYZER WITH AUTOMATIC DIFFERENTIAL DEADTIME CORRECTION
    BYRD, JS
    GOOSEY, MH
    NUCLEAR INSTRUMENTS & METHODS, 1979, 158 (2-3): : 565 - 569
  • [5] LESION DETECTION PERFORMANCE AND PULSE-HEIGHT SELECTION
    ASHARE, AB
    RAUF, CG
    DUBUQUE, GL
    KEREIAKE.JG
    SOUTHERN MEDICAL JOURNAL, 1973, 66 (11) : 1329 - 1329
  • [6] THE CORRECTION OF RESOLUTION DISTORTION IN CONTINUOUS PULSE-HEIGHT SPECTRA
    WORTMAN, DE
    GRAMER, JG
    NUCLEAR INSTRUMENTS & METHODS, 1964, 26 (02): : 257 - 262
  • [7] IMPROVED METHOD FOR LIVETIME CORRECTION IN PULSE-HEIGHT SPECTROSCOPY
    HARTMANN, G
    KLEIN, JW
    FAATZ, H
    NUCLEAR INSTRUMENTS & METHODS, 1972, 102 (02): : 361 - &
  • [8] CORRECTION FOR PEAK PILE UP IN PULSE-HEIGHT SPECTROSCOPY
    JOHNS, PC
    YAFFE, MJ
    HOLMES, RB
    MEDICAL PHYSICS, 1987, 14 (03) : 455 - 455
  • [9] PULSE-HEIGHT ANALYSIS OF A LARGE COUNTER SYSTEM
    INYAKIN, AV
    JOHNSON, RP
    KRASNOKUTSKY, RN
    LEBEDEV, AA
    MIKHAILOV, YV
    PROKOSHKIN, YD
    SHUVALOV, RS
    NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (03): : 385 - 387
  • [10] COMPUTER SYSTEM USED FOR PULSE-HEIGHT ANALYSIS
    SCHIMA, FJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 : 36 - 36