Hemostatic and fibrinolytic activation is less following cutting balloon angioplasty of the coronary arteries

被引:7
|
作者
Namiki, A
Toma, H
Nakamura, M
Matsuda, K
Hara, H
Hara, H
Asahara, T
Soumitsu, Y
Kobayashi, N
Yamaguchi, T
机构
[1] Toho Univ, Sch Med, Ohashi Hosp, Dept Internal Med 3, Tokyo 153, Japan
[2] Toranomon Gen Hosp, Tokyo, Japan
来源
JAPANESE HEART JOURNAL | 2004年 / 45卷 / 03期
关键词
percutaneous coronary intervention; plain old balloon angioplasty; coronary stenting; cutting balloon; prothrombin fragment 1+2; fibrinopeptide A; thrombin-antithrombin IIIcomplex; plasminogen activator inhibitor-1;
D O I
10.1536/jhj.45.409
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent studies have shown that percutaneous coronary intervention (PCI) activates systemic hemostatic activity, reflecting platelet activation and thrombin formation in the coronary arteries. The present study compared systemic levels of hemostatic markers induced by plain old balloon angioplasty (POBA), coronary stenting (STENT), and cutting balloon (CB) angioplasty. Sixty-one patients with stable angina pectoris, who underwent elective PCI or diagnostic coronary angiography (CAG) alone, were investigated. Patients who underwent PCI were divided into the POBA group (n = 11), the STENT group (n = 27), and the CB group (n = 11). Patients who underwent CAG alone were assigned to the CAG group (n = 12). Blood samples were collected before, 24 hours after, and 3 days after PCI or CAG. Plasma concentrations of prothrombin fragment 1+2 (F1+2), fibrinopeptide A (FPA), thrombi n-antithrombin III complex (TAT), and Plasminogen activator inhibitor-1 (PAI-1) were measured. In the CB group, the F1+2 (1.23 +/- 0.4 nmol/L) level 3 days after PCI was significantly smaller than that of the POBA group (2.37 +/- 0.5 nmol/L) (P < 0.05). The FPA (1.81 +/- 0.9 ng/mL), TAT (3.36 +/- 1.2 ng/mL) and PAI-1 (23.0 +/- 4.1 ng/mL) levels in the CB group 3 days after PCI were significantly smaller than those of the POBA group (P < 0.05, respectively) and STENT group (P < 0.05, respectively), but similar to the CAG group. Systemic hemostasis is activated to a greater extent after POBA and stenting than it is after CB angioplasty of the coronary arteries. This may contribute to the favorable longterrn outcome of CB angioplasty.
引用
收藏
页码:409 / 417
页数:9
相关论文
共 50 条
  • [41] SUCCESSFUL ROTATIONAL CORONARY ABLATION FOLLOWING FAILED BALLOON ANGIOPLASTY
    IYER, SS
    HALL, P
    KING, JF
    DORROS, G
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (01): : 65 - 68
  • [42] LOCAL RELEASE OF ENDOTHELIN IN HUMAN CORONARY-ARTERIES IN RESPONSE TO BALLOON ANGIOPLASTY
    LERMAN, A
    HOLMES, DR
    GARRATT, KN
    REEDER, GS
    BELL, MR
    BURNETT, JC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A124 - A124
  • [43] Numerical simulation of arterial dissection during balloon angioplasty of atherosclerotic coronary arteries
    Badel, Pierre
    Avril, Stephane
    Sutton, Michael A.
    Lessner, Susan M.
    JOURNAL OF BIOMECHANICS, 2014, 47 (04) : 878 - 889
  • [44] Sirolimus Coated Balloon Angioplasty for In-stent Restenosis in Small Coronary Arteries
    Dani, Sameer
    Parikh, Keyur
    Shetty, Ranjan
    Pillai, PrathapKumar
    Hiremath, Jagdish
    Shah, Dinesh
    Di Palma, Gaetano
    Cortese, Bernardo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S41 - S41
  • [45] Randomized comparison of coronary stenting with optimal balloon angioplasty for treatment of lesions in small coronary arteries
    Park, SW
    Lee, CW
    Hong, MK
    Kim, JJ
    Cho, GY
    Nah, DY
    Park, SJ
    EUROPEAN HEART JOURNAL, 2000, 21 (21) : 1785 - 1789
  • [46] A randomized comparison of elective stenting and balloon angioplasty in the treatment of small coronary arteries
    Savage, MP
    Fischman, DL
    Kada, F
    Fry, ETA
    Kiernan, FJ
    Goldberg, S
    CIRCULATION, 1999, 100 (18) : 503 - 503
  • [47] Comparison of the results of stenting and balloon angioplasty of coronary arteries in relation to the type of stenosis
    Puretskij, M.V.
    Abugov, S.A.
    Saakyan, Yu.M.
    Vestnik Rentgenologii i Radiologii, 2003, (02) : 25 - 31
  • [48] Coronary artery perforation and delayed cardiac tamponade following balloon coronary angioplasty
    Tseng, CD
    Chen, GY
    Chiang, FT
    Hsu, KL
    Lo, HM
    Tseng, YZ
    Tsai, CH
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1996, 95 (10) : 789 - 792
  • [49] Self-expanding coronary Stent (radius) implantation with cutting balloon angioplasty
    Lee, SH
    Choi, SH
    Ko, YG
    Choi, DH
    Jang, YS
    Shim, WH
    CARDIOLOGY, 2005, 103 (03) : 123 - 127
  • [50] Development of coronary aneurysm after cutting balloon angioplasty: Assessment by intracoronary ultrasound
    Bertrand, OF
    Mongrain, R
    Soualmi, L
    Rodes, J
    Tardif, JC
    Crepeau, J
    Bonan, R
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 44 (04): : 449 - 452