Optimum conditions and application of one-step fluorescent cyanoacrylate fuming method for fingermark development based on PolyCyano UV

被引:1
|
作者
Li, Kang [1 ,2 ]
Li, Shuo [2 ]
Yang, Jun [2 ]
机构
[1] Zhejiang Police Coll, Forens Sci Dept, Hangzhou, Peoples R China
[2] Peoples Publ Secur Univ China, Sch Invest, Beijing, Peoples R China
关键词
Forensic sciences; polyCyano UV; latent fingermark; developing conditions; fluorescence technique; one-step fuming;
D O I
10.1080/20961790.2022.2049153
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Cyanoacrylate fluorescent staining has become a common method for developing latent fingermarks on light-coloured or white objects. The method requires two steps and skilled operation, and the handling process has the risk of damaging the ridge details or even biological samples. To take full advantage of the high-sensitivity fluorescence, recent research efforts on fluorescent cyanoacrylate have aimed to avoid rinsing after staining, add fluorescence to the cyanoacrylate, increase the fluorescence intensity and broaden the fluorescence spectral range. PolyCyano UV is a novel product that can be used to overcome the disadvantages associated with progressing to one-step fuming to directly develop fingermarks. To explore the optimal development conditions and application effects of PolyCyano UV, thermogravimetric differential thermal analysis, fluorescence spectroscopy and control variable analysis are used to determine and analyse the best conditions for using the reagent, including temperature, fluorescence excitation band, relative humidity and fuming concentration. The temperature range of the one-step fuming development method is 212.14 degrees C-275.16 degrees C, the wavelength range of the excitation light source is 235-580 nm, the relative humidity is 60%-80%, the concentration of the fume is 1-3 g/m(3) and the specific value is related to the surface properties of the object and the aged time of the fingermarks. Additionally, fluorescence spectroscopy shows that the excitation wavelength range of the light source is 235-580 nm. Based on the best fuming condition, many common objects were selected to proceed to the application experiments, which allowed for a comparison with the traditional visualisation method, namely the Cyanobloom reagent + dyeing two-step development method. The comparison showed that latent fingermarks on most non-porous smooth surfaces, especially on light-coloured or white objects, were developed successfully. In addition, a comparative study with the conventional cyanoacrylate glue-fluorescent staining experiments showed that the effect of dyeing afterwards with Rhodamine 6 G is better than the one-step method. The effect of dyeing with BBD is basically the same as that of the one-step method.
引用
收藏
页码:550 / 559
页数:10
相关论文
共 36 条
  • [1] PolyCyano UV: an investigation into a one-step luminescent cyanoacrylate fuming process
    Chadwick, Scott
    Xiao, Linda
    Maynard, Philip
    Lennard, Chris
    Spindler, Xanthe
    Roux, Claude
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2014, 46 (04) : 471 - 484
  • [2] Lumicyano™: A new fluorescent cyanoacrylate for a one-step luminescent latent fingermark development
    Prete, Cosimo
    Galmiche, Laurent
    Quenum-Possy-Berry, Fifonsi-Gwladys
    Allain, Clemence
    Thiburce, Nicolas
    Colard, Thomas
    FORENSIC SCIENCE INTERNATIONAL, 2013, 233 (1-3) : 104 - 112
  • [3] A simple one-step method for preparation of fluorescent carbon nanospheres and the potential application in cell organelles imaging
    Ruan, Shaobo
    Zhu, Biyue
    Zhang, Huajin
    Chen, Jiantao
    Shen, Shun
    Qian, Jun
    He, Qin
    Gao, Huile
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2014, 422 : 25 - 29
  • [4] One-step solid-phase UV spectrophotometric method for phenol determination in vaccines: Development and quality assessment
    J. Vuković
    R. Jurišić Grubešić
    D. Kremeŕ
    A. Spaić
    Journal of Analytical Chemistry, 2013, 68 : 1033 - 1043
  • [6] One-step solid-phase UV spectrophotometric method for phenol determination in vaccines: Development and quality assessment
    Vukovic, J.
    Grubesic, R. Jurisic
    Kremer, D.
    Spaic, A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (12) : 1033 - 1043
  • [7] Coumarin-based fluorescent probe synthesized by one-step reaction for sensitive detection of hydrazine and its application
    Geng, Xiangdong
    Zheng, Xiaoyan
    Tang, Keyong
    Liu, Jie
    CHEMISTRY LETTERS, 2024, 53 (03)
  • [8] Optimum conditions for novel one-step cleaning method for pre-gate oxide cleaning using robust design methodology
    Pan, TM
    Lei, TF
    Chao, TS
    Liaw, MC
    Lu, CP
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2000, 39 (10): : 5805 - 5808
  • [9] Optimum conditions for novel one-step cleaning method for pre-gate oxide cleaning using robust design methodology
    Pan, Tung Ming
    Lei, Tan Fu
    Chao, Tien Sheng
    Liaw, Ming Chi
    Lu, Chih Peng
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2000, 39 (10): : 5805 - 5808
  • [10] One-step synthesis of epoxy-based silicon prepolymers and its application in UV-curable coating
    Fuping Bian
    Xiaoquan Li
    Jihe Zhao
    Jiwen Hu
    Xuefeng Gui
    Shi Li
    Shudong Lin
    Journal of Coatings Technology and Research, 2023, 20 : 321 - 331