Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device

被引:0
|
作者
Fiedorova, Klara [1 ]
Augustynek, Martin [1 ]
Kubicek, Jan [1 ]
Penhaker, Marek [1 ]
Vodakova, Andrea [1 ]
Korhelik, Karol [2 ]
机构
[1] VSB Tech Univ Ostrava, FEECS, 17 Listopadu 15,K450, Ostrava, Czech Republic
[2] Univ Ostrava, Fac Med, Inst Diagnost Imaging, Syllabova 19, Ostrava, Czech Republic
关键词
X-ray; Secondary radiation; Computed radiography cassette; Imaging plate; Multilevel Otsu method;
D O I
10.1007/978-3-030-31635-8_197
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Nowadays, the use of X-ray is an important part of imaging techniques used in medicine. The resulting skiagraphy images are kept in the workplace and can be influenced by secondary radiation, which occurs as a secondary effect when irradiated with X-rays. This secondary radiance has not to effect only for the skiagraphy images but also for the human body. The effect of secondary radiation is irreversible image acquisition, which can lead to poor diagnosis and poor clinical information. Currently, there are no techniques and methods available to determine the extent of secondary damage to the skiagraphy cassette. In the work, we analyse the influence of secondary radiation on the quality of the skiagraphy images using mobile X-ray devices. During image analysis, a multi-region segmentation method is used to determine pixels that are affected by irradiation. By this method, we are able to derive the characteristics of the image, determine the level of irradiation and estimate the effect of secondary radiation.
引用
收藏
页码:1599 / 1608
页数:10
相关论文
共 50 条
  • [31] X-ray image intensifier
    Balter, S
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 46 (02) : 238 - 244
  • [32] X-ray image holography
    Zhu, Peiping
    Gao, Hongyi
    Jiang, Shiping
    Chen, Min
    Cui, Mingqi
    Xu, Zhizhan
    Chen, Jianwen
    Guangxue Xuebao/Acta Optica Sinica, 2001, 21 (07): : 850 - 852
  • [33] X-RAY IMAGE INTENSIFIER
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1954, 2 (4895): : 1044 - 1044
  • [34] Quality and image restoration in secondary X-ray imaging, with human angiography as an example
    Csonka, P. L.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [35] X-RAY MICROSCOPY AND X-RAY MICROANALYSIS
    COSSLETT, VE
    NATURE, 1959, 184 (4690) : 860 - 862
  • [36] X-RAY OPTICS AND X-RAY MICROANALYSIS
    WERNER
    METALL, 1966, 20 (05): : 550 - &
  • [37] X-ray physics and x-ray tubes
    Hicks, V
    JOURNAL OF APPLIED PHYSICS, 1941, 12 (05) : 364 - 374
  • [38] X-RAY OPTICS + X-RAY MICROANALYSIS
    HEINRICH, KF
    AMERICAN SCIENTIST, 1965, 53 (03) : A382 - &
  • [39] X-Ray Inerferometer with a X-Ray Beamsplitter
    Kitamoto, S.
    Sakata, K.
    Murakami, H.
    Yoshida, Y.
    Seta, H.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [40] X-RAY OPTICS AND X-RAY MICROANALYSIS
    AXON, HJ
    JOURNAL OF THE INSTITUTE OF METALS, 1965, 93 : 607 - &