Spectra-resolved technique of a sensitive time-resolved fluorescence immunoassay instrument

被引:0
|
作者
Guo, ZY [1 ]
Tian, Z [1 ]
Jia, YL [1 ]
机构
[1] S China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Peoples R China
关键词
spectra-resolved technology; time-resolved fluorescence; immunoassay; lanthanide;
D O I
10.1117/12.572442
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The lanthanide trivalence ion and its chelates are used for marking substance in time-resolved fluorescence immunoassay (TRFIA), marking the protein, hormone, antibody, nucleic acid probe or biologic alive cell, to measure the concentration of the analysis substance inside the reaction system with time-resolved fluorometry after the reaction system occurred, and attain the quantitative analysis's purpose. TRFIA has been become a kind of new and more sensitive measure method after radioisotope marking, enzymatic marking, chemiluminescence, electrochemiluminescence, it primarily is decided by the special physics and chemistry characteristic of lanthanide trivalence ion and its chelates. In this paper, the result of spectroscopic evaluation of europium trivalence ion and its chelate, and the principle of spectra-resolved technology and a sensitive time-resolved fluorescence immunoassay instrument made by ourselves are reported. In the set, a high frequency Xenon pulsed-light was adopted as exciting light, and two special filters was utilized according to spectra-resolved technique. Thus the influence of scattering light and short-lifetime fluorescence was removed. And the sensitivity is 10(-12)mol/L (when Eu3+ was used for marking substance), examination repeat is CVless than or equal to5 %, examination linearity is from 10 (-8) mol/L to 10(-12)mol/L, correlation coefficient rgreater than or equal to95%(p<0.01).
引用
收藏
页码:222 / 226
页数:5
相关论文
共 50 条
  • [41] A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W
    Huang, Biao
    Yu, Huixin
    Bao, Jiandong
    Zhang, Manda
    Green, William L.
    Wu, Sing-Yung
    BIOMARKER INSIGHTS, 2018, 13
  • [42] Study of solid-phase time-resolved fluorescence label immunoassay
    Pan, LH
    Zhou, SH
    Sun, WW
    Xie, WB
    Zhao, C
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (12) : 1601 - 1604
  • [43] A Novel Europium Chelate Coated Nanosphere for Time-Resolved Fluorescence Immunoassay
    Shen, Yifeng
    Xu, Shaohan
    He, Donghua
    PLOS ONE, 2015, 10 (06):
  • [44] One step time-resolved fluorescence immunoassay for direct estimation of microcystins
    Lei, La-Mei
    Han, Bo-Ping
    Song, Li-Rong
    Huanjing Kexue/Environmental Science, 2007, 28 (04): : 872 - 875
  • [45] TIME-RESOLVED FLUORESCENCE IMAGING
    SCHNECKENBURGER, H
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1994, 24 (01) : 63 - 65
  • [46] Time-resolved fluorescence microscopy
    Klaus Suhling
    Paul M. W. French
    David Phillips
    Photochemical & Photobiological Sciences, 2005, 4 : 13 - 22
  • [47] A TIME-RESOLVED FLUORESCENCE MICROSCOPE
    FRENCH, T
    SO, P
    BERLAND, K
    GRATTON, E
    BIOPHYSICAL JOURNAL, 1993, 64 (02) : A110 - A110
  • [48] Sensitive time-resolved fluorometer
    Tian, Z
    Guo, ZY
    Optical Design and Testing II, Pts 1 and 2, 2005, 5638 : 698 - 704
  • [49] Time-resolved spectra of sonoluminescence
    Hiller, RA
    Putterman, SJ
    Weninger, KR
    PHYSICAL REVIEW LETTERS, 1998, 80 (05) : 1090 - 1093
  • [50] Ultra-sensitive method based on time-resolved fluorescence immunoassay for detection of sulfamethazine in raw milk
    Hu, Song
    Li, Danhong
    Huang, Zhen
    Xing, Keyu
    Chen, Yuan
    Peng, Juan
    Lai, Weihua
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 1137 - 1149