Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate

被引:0
|
作者
Hessler, C. [1 ]
Schmucker, U.
Matthes, G.
Ekkernkamp, A.
Guetschow, R.
Eggers, C.
机构
[1] Klinikum Ernst Moritz Arndt Univ, Abt Unfall & Wiederherstellungschirurgie, D-17475 Greifswald, Germany
[2] Allgemeines Krankenhaus Barmbek, Abt Unfall & Wiederherstellungschirurgie, Hamburg, Germany
[3] Allgemeines Krankenhaus St Georg, Chirurg Traumatol Klin, Hamburg, Germany
来源
UNFALLCHIRURG | 2006年 / 109卷 / 10期
关键词
fracture of the proximal humerus; fixed-angle plates; surgical technique;
D O I
10.1007/s00113-006-1138-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Fixed-angle implants are being increasingly used in surgery of fractures of the proximal humerus. The aim of this retrospective investigation was to evaluate the outcome after fracture reduction utilizing a fixed-angle plate (Konigsee((R))). Materials and methods. Between January 2003 and April 2004, 58 patients were operated, 52 of whom received a fixed-angle implant; 46 cases were harvested for a follow-up examination. Each patient was re examined clinically and radiologically at least 6 and 18 months after surgery. The functional outcome was evaluated using the Constant Score and the Simple Shoulder Test. The results were compared to results of other investigations. Results. The mean patient age was 68.8 years (34-94 years). Fractures were classified using the Neer Classification: 12 were classified as two-part, 25 as three-part, and 9 as four-part fractures. Three of the three-part and four of the four-part fractures were rated as luxation fractures. The overall functional outcome of all cases was good. More than 18 months after surgery the mean general "Constant Score" was 57; the mean side-related "Constant Score" was 89%. The Simple Shoulder Test revealed a pain-free range of motion in 41 (89.1%)of the individuals. The majority of the patients were satisfied with the results regarding remaining range of activity of the injured limb. In five cases significant complications occurred. In two cases the head of the humerus collapsed, and in one case a necrosis of the head occurred. In one individual the implant broke after an additional trauma. In this case a re-osteosynthesis utilizing a tibia plate was performed and the patient was excluded from further follow-up investigations. One soft tissue infection occurred after initial surgery. Conclusion. It has been shown that results after fixation of proximal humerus fractures with fixed-angle implants are good. The functional outcome is good and complications are rare. Our results correlate with other investigations regarding fracture reduction using fixed-angle plates and nails.
引用
收藏
页码:867 / +
页数:7
相关论文
共 50 条
  • [21] Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system
    Kimmeyer, Michael
    Schmalzl, Jonas
    Rentschler, Verena
    Jessen, Malik
    Gerhardt, Christian
    Lehmann, Lars-Johannes
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [22] Early results of treatment of proximal humerus fractures with the PHILOS locking plate
    Kilic, Buelent
    Uysal, Mustafa
    Cinar, Bekir Murat
    Oezkoc, Guerkan
    Demiroers, Hueseyin
    Akpinar, Sercan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2008, 42 (03) : 149 - 153
  • [23] Mid term results of PlantTan plate in the treatment of proximal humerus fractures
    Machani, B
    Sinopidis, C
    Brownson, P
    Papadopoulos, P
    Gibson, J
    Frostick, SP
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (03): : 269 - 276
  • [24] Surgical treatment of proximal humerus fractures using PHILOS plate
    Kumar, G. N. Kiran
    Sharma, Gaurav
    Sharma, Vijay
    Jain, Vaibhav
    Farooque, Kamran
    Morey, Vivek
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (05) : 279 - 284
  • [25] Proximal humerus fracture in advanced age -: Treatment with fixed angle plate osteosynthesis
    Köstler, W
    Strohm, PC
    Südkamp, NP
    CHIRURG, 2003, 74 (11): : 985 - 989
  • [26] Can the outcome of proximal humeral fractures be improved using a minimally invasive surgical technique for fixed-angle plate osteosynthesis?
    Ketterl, Rupert
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2013, 8 (03): : 158 - 164
  • [27] Treatment of intertrochanteric femur fractures with 95° fixed-angle blade plate in elderly patients
    Cumhur Cevdet Kesemenli
    Kaya Memişoğlu
    Serdar Necmioğlu
    Cuma Kayıkçı
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 629 - 634
  • [28] Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study
    Hessmann, Martin H.
    Korner, Jan
    Hofmann, Alexander
    Sternstein, Werner
    Rommens, Pol M.
    BIOMEDIZINISCHE TECHNIK, 2008, 53 (03): : 130 - 137
  • [29] Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results
    Markus Figl
    Patrick Weninger
    Michael Liska
    Marcus Hofbauer
    Martin Leixnering
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 661 - 669
  • [30] Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results
    Figl, Markus
    Weninger, Patrick
    Liska, Michael
    Hofbauer, Marcus
    Leixnering, Martin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (05) : 661 - 669