An Automated Permuting Capacitor Device for Calibration of IVDs

被引:8
|
作者
Hsu, Jimmy C. [1 ,2 ]
Gong, Jeng [3 ]
Huang, Chih-Fang [2 ]
机构
[1] Ind Technol Res Inst, Ctr Measurement Stand, Hsinchu 30011, Taiwan
[2] Natl Tsing Hua Univ, Inst Elect Engn, Hsinchu 30013, Taiwan
[3] Tunghai Univ, Dept Elect Engn, Taichung 407, Taiwan
关键词
Coaxial microwave switch; four-terminal-pair (4TP); inductive voltage divider (IVD); permuting capacitors; INDUCTIVE VOLTAGE DIVIDERS; 1; MHZ; BRIDGE; FREQUENCIES; KHZ; DEPENDENCE; RESISTANCE;
D O I
10.1109/TIM.2014.2308035
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new automated permuting capacitor device (APCD) for calibration of inductive voltage dividers (IVDs) with four-terminal-pair definition was designed and tested. The permuting capacitors composed of 11-SMD capacitors were housed in a bulk metal in a symmetrical arrangement. Thus, the APCD is compact and the temperature of the APCD could be controlled within several mKs. Using coaxial microwave switches, the APCD was permuted quickly and automatically using electrical signals during the calibration process. This prevented the APCD from being thermally perturbed by manual operation. Owing to the improved stability of the device, the effects of stray capacitance and voltage coefficient of the APCD were evaluated accurately. The calibration of an IVD using the permuting capacitor method with this APCD in the frequency range 1-2 kHz with accuracy comparable with that of the straddling method is presented in this paper.
引用
收藏
页码:2271 / 2278
页数:8
相关论文
共 50 条
  • [21] An ISFET automated output calibration system implementation on reconfigurable FPGA device with MATLAB Artificial Intelligence interfacing
    Saini, Deepa
    Rupani, Ajay
    Sujediya, Gajendra
    Sharma, Tushar
    PROCEEDINGS OF THE 2017 3RD INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL COMPUTING AND COMMUNICATION TECHNOLOGY (ICATCCT), 2017, : 354 - 358
  • [22] CALIBRATION OF AUTOMATED THYROTROPIN ASSAYS
    SADLER, WA
    VANDERSPLINTER, TM
    MURRAY, LM
    TURNER, JG
    CLINICAL CHEMISTRY, 1993, 39 (05) : 904 - 905
  • [23] Automated system for DMM calibration
    Slavov, Vladislav
    Tashev, Tasho
    Mladenov, Valeri
    CIMMACS '07: PROCEEDINGS OF THE 6TH WSEAS INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE, MAN-MACHINE SYSTEMS AND CYBERNETICS, 2007, : 372 - +
  • [24] Automated Calibration Machine for Spirometers
    Chaaya, Pamela
    Sassiya, Bedouin
    Ghnatios, Chady
    Kassem, Abdallah
    2019 FOURTH INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTATIONAL TOOLS FOR ENGINEERING APPLICATIONS (ACTEA), 2019,
  • [25] Automated calibration training for forecasters
    Stone, Eric R.
    Luu, Jason
    Costello, Cory K.
    Somerville, Annie H.
    JOURNAL OF BEHAVIORAL DECISION MAKING, 2023, 36 (04)
  • [26] AN AUTOMATED THERMOCOUPLE CALIBRATION SYSTEM
    BETHEA, MD
    ROSENTHAL, BN
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (05) : 702 - 706
  • [27] Automated calibration of graduated scales
    Chávez, G
    Valera, B
    Padilla, S
    2004 1st International Conference on Electrical and Electronics Engineering (ICEEE), 2004, : 385 - 390
  • [28] An automated robot calibration system
    Robinson, P
    Orzechowski, P
    James, PW
    Smith, C
    ISIE '97 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-3, 1997, : SS285 - SS290
  • [29] AUTOMATED SOLAR GAIN CALIBRATION
    PRATTE, JF
    FERRARO, DG
    24TH CONFERENCE ON RADAR METEOROLOGY, 1989, : 619 - 622
  • [30] Automated system for the calibration of magnetometers
    Petrucha, Vojtech
    Kaspar, Petr
    Ripka, Pavel
    Merayo, Jose M. G.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (07)