Arterial to inspired partial pressure ratio of halothane, isoflurane, sevoflurane and desflurane in rats

被引:11
|
作者
Holdcroft, A [1 ]
Bose, D [1 ]
Sapsed-Byrne, SM [1 ]
Ma, D [1 ]
Lockwood, GG [1 ]
机构
[1] Imperial Coll, Sch Med, Hammersmith Hosp, Dept Anaesthesia, London W12 0HS, England
关键词
anaesthetics; volatile; halothane; isoflurane; sevoflurane; desflurane; rat; partial pressure; arterial; inspired;
D O I
10.1093/bja/83.4.618
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The inspired partial pressure of an anaesthetic is often used as an index of arterial partial pressure in small animal experiments. We have investigated the influence of anaesthetic solubility on the ratio of arterial to inspired partial pressure in 24 rats, allocated randomly to receive halothane, isoflurane or desflurane at four different inspired concentrations. The arterial partial pressure of the volatile agent was measured by two-stage headspace analysis using a gas chromatograph calibrated with the same gas used to calibrate the Datex Capnomac that measured the inspired concentration. Mean values of arterial to inspired ratio at the lowest concentrations were 0.60 (95% confidence intervals 0.50, 0.71) for 0.8% halothane, 0.54 (0.38, 0.69) for 0.8% isoflurane, 0.72 (0.59, 0.86) for 1.5% sevoflurane and 0.71 (0.54, 0.87) for 4% desflurane. Analysis of variance showed a significant effect of anaesthetic agent (P = 0.008) on the arterial to inspired ratio. Thus volatile anaesthetic agents do not demonstrate a fixed arterial to inspired ratio in rats.
引用
收藏
页码:618 / 621
页数:4
相关论文
共 50 条
  • [41] IS THE END-TIDAL PARTIAL-PRESSURE OF ISOFLURANE A GOOD PREDICTOR OF ITS ARTERIAL PARTIAL-PRESSURE
    FREI, FJ
    ZBINDEN, AM
    THOMSON, DA
    RIEDER, HU
    BRITISH JOURNAL OF ANAESTHESIA, 1991, 66 (03) : 331 - 339
  • [42] Comparison of end-tidal CO2 and arterial oxygen saturation during halothane, isoflurane or sevoflurane anaesthesia in dogs
    Topal, A
    Gul, N
    Gorgul, OS
    INDIAN VETERINARY JOURNAL, 2004, 81 (12): : 1345 - 1347
  • [43] Pulse pressure variation and stroke volume variation under different inhaled concentrations of isoflurane, sevoflurane and desflurane in pigs undergoing hemorrhage
    Oshiro, Alexandre Hideaki
    Otsuki, Denise Aya
    Hamaji, Marcelo Waldir M.
    Rosa, Kaleizu T.
    Ida, Keila Kazue
    Fantoni, Denise T.
    Costa Auler, Jose Otavio, Jr.
    CLINICS, 2015, 70 (12) : 804 - 809
  • [44] RATES OF AWAKENING FROM ANESTHESIA WITH I-653, HALOTHANE, ISOFLURANE, AND SEVOFLURANE - A TEST OF THE EFFECT OF ANESTHETIC CONCENTRATION AND DURATION IN RATS
    EGER, EI
    JOHNSON, BH
    ANESTHESIA AND ANALGESIA, 1987, 66 (10): : 977 - 982
  • [45] Pulmonary-to-systemic blood flow ratio effects of sevoflurane, isoflurane, halothane, and fentanyl/midazolam with 100% oxygen in children with congenital heart disease
    Laird, TH
    Stayer, SA
    Rivenes, SM
    Lewin, MB
    McKenzie, ED
    Fraser, CD
    Andropoulos, DB
    ANESTHESIA AND ANALGESIA, 2002, 95 (05): : 1200 - 1206
  • [46] THE PARTIAL-PRESSURE OF ISOFLURANE OR HALOTHANE DOES NOT AFFECT THEIR SOLUBILITY IN BLOOD - INHALED ANESTHETICS OBEY HENRYS LAW
    COBURN, CM
    EGER, EI
    ANESTHESIA AND ANALGESIA, 1986, 65 (06): : 672 - 674
  • [47] Effect of different inspired fractions of oxygen on F-shunt and arterial partial pressure of oxygen in isoflurane-anaesthetized and mechanically ventilated Shetland ponies
    Rodriguez, Abraham Calero
    de Grauw, Janny C.
    van Loon, Johannes P. A. M.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2021, 48 (06) : 930 - 934
  • [48] Prediction of Fraction of Inspired Oxygen to Achieve a Desired Arterial Partial Pressure of Oxygen
    El-Khatib, Mohamad
    Chatburn, Robert L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2012, 185 (06) : 685 - 686
  • [49] ARTERIAL-ALVEOLAR OXYGEN PARTIAL-PRESSURE RATIO - REPLY
    VIALE, JP
    CRITICAL CARE MEDICINE, 1987, 15 (05) : 540 - 541
  • [50] Concentration-Effect relations, prediction probabilities (Pk), and signal-to-noise ratios of different electroencephalographic parameters during administration of desflurane, isoflurane, and sevoflurane in rats
    Ihmsen, Harald
    Schywalsky, Michael
    Plettke, Regina
    Priller, Michael
    Walz, Florian
    Schwilden, Helmut
    ANESTHESIOLOGY, 2008, 108 (02) : 276 - 285