Depletive stripping chronopotentiometry: A major step forward in electrochemical stripping techniques for metal ion speciation analysis

被引:41
|
作者
Town, RM [1 ]
van Leeuwen, HP
机构
[1] Queens Univ Belfast, Sch Chem, Belfast BT9 5AG, Antrim, North Ireland
[2] Univ Wageningen & Res Ctr, Lab Phys Chem & Colloid Sci, NL-6703 HB Wageningen, Netherlands
关键词
metal speciation; stripping chronopotentiometry; stripping voltammetry;
D O I
10.1002/elan.200302844
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comparative evaluation of the utility of the various modes of stripping chronopotentiometry (SCP) for trace metal speciation analysis is presented in the broad context of stripping voltammetric techniques. The remarkable fundamental advantages of depletive SCP at scanned deposition potential (SSCP) are highlighted, and the rigorous underpinning theory is described. The distinctive features of SSCP include: i) an effective getting around part of the Nernstian extension of the reoxidation process, leading to ii) greater resolution than conventional stripping voltammetries; iii) a certain insensitivity to electrochemical irreversibility, especially at a microelectrode; iv) in principle, freedom from induced metal ion adsorption interferences; v) no requirement for excess ligand during stripping; and vi) ability to provide a certain measure of any chemical heterogeneity in the metal speciation that is easily distinguishable from effects of electrochemical irreversibility.
引用
收藏
页码:458 / 471
页数:14
相关论文
共 46 条
  • [21] Electrochemical stripping techniques in analysis of nucleic acids and their constituents
    Fojta, Miroslav
    Jelen, Frantisek
    Havran, Ludek
    Palecek, Emil
    CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) : 250 - 262
  • [22] Fundamental features of metal ion determination by stripping chronopotentiometry (vol 509, pg 58, 2001)
    Town, RM
    van Leeuwen, HP
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 515 (1-2): : 129 - 129
  • [23] Trace metal dynamic speciation studied by scanned stripping chronopotentiometry (SSCP) (vol 5, pg 24, 2008)
    Domingos, Rute F.
    Lopez, Rocio
    Pinheiro, Jose P.
    ENVIRONMENTAL CHEMISTRY, 2008, 5 (02) : 169 - U15
  • [24] Determination of trace metal speciation parameters by using screen-printed electrodes in stripping chronopotentiometry without deaerating
    Parat, C.
    Schneider, A.
    Castetbon, A.
    Potin-Gautier, M.
    ANALYTICA CHIMICA ACTA, 2011, 688 (02) : 156 - 162
  • [25] Significance of wave form parameters in stripping chronopotentiometric metal speciation analysis
    Town, RM
    van Leeuwen, HP
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 535 (1-2) : 11 - 25
  • [26] Interference Analysis for Electrochemical Heavy Metal Ion Sensors in Terms of Stripping Current, Barrier Width and Adsorption
    Dutta, Kusumita
    Panda, Siddhartha
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (13) : B644 - B650
  • [27] Adsorptive accumulation in constant current stripping chronopotentiometry as an alternative for the electrochemical study of metal complexation by thiol-containing peptides
    Serrano, Nuria
    Sestakova, Ivana
    Diaz-Cruz, Jose Manuel
    Arino, Cristina
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 591 (01) : 105 - 117
  • [28] Integration of microfluidics/electrochemical system for trace metal analysis by stripping voltammetry
    Lin, YH
    Zhao, R
    Thrall, KD
    Timchalk, CA
    Bennett, WD
    Matson, DW
    MICROFLUIDIC DEVICES AND SYSTEMS II, 1999, 3877 : 248 - 256
  • [29] Suitability of stripping chronopotentiometry for heavy metal speciation using hydrogen peroxide as oxidant:: Application to the Cd(II)-EDTA-PMA system
    Serrano, N
    Gómez-Boadas, MD
    Díaz-Cruz, JM
    Berbel, F
    Ariño, C
    Esteban, M
    ELECTROANALYSIS, 2005, 17 (24) : 2201 - 2207
  • [30] Thick film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label
    Wang, J
    Tian, BM
    Rogers, KR
    ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1682 - 1685