Microfluidic chip capillary electrophoresis coupled with electrochemiluminescence for enantioseparation of racemic drugs using central composite design optimization

被引:22
|
作者
Guo, Wen Peng [1 ,2 ]
Rong, Zhi Bin [1 ,3 ]
Li, Ying Hong [1 ]
Fung, Ying Sing [2 ]
Gao, Guo Quan [1 ]
Cai, Zhi Ming [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Sch Med, Shenzhen Peoples Hosp 2, Guangzhou, Guangdong, Peoples R China
[2] Univ Hong Kong, Dept Chem, Hong Kong, Hong Kong, Peoples R China
[3] Shijiazhuang Maternal & Child Hlth Care Hosp, Shijiazhuang, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Central composite design; Enantioseparation; Ferrofluid valve; Microchip-CE; Spiral channel; CHIRAL SEPARATIONS; CHROMATOGRAPHY; PERFORMANCE; COLUMNS; URINE; CE;
D O I
10.1002/elps.201300238
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optimization based on central composite design (CCD) for enantioseparation of anisodamine (AN), atenolol (AT), and metoprolol (ME) in human urine was developed using a microfluidic chip-CE device. Coupling the flexible and wide working range of microfluidic chip-CE device to CCD for chiral separation of AN, AT, and ME in human urine, a total of 15 experiments is needed for the optimization procedure as compared to 75 experiments using the normal one variable at a time optimization. The optimum conditions obtained are found to be more robust as shown by the curvature effects of the interaction factors. The developed microfluidic chip-CE-ECL system with adjustable dilution ratios has been validated by satisfactory recoveries (89.5-99% for six enanotiomers) in urine sample analysis. The working range (0.3-600 M), repeatability (3.1-4.9% RSD for peak height and 4.0-5.2% RSD for peak area), and detection limit (0.3-0.6 M) of the method developed are found to meet the requirements for bedside monitoring of AN, AT, and ME in patients under critical conditions. In summary, the hyphenation of CCD with the microfluidic chip-CE device is shown to offer a rapid means for optimizing the working conditions on simultaneous separation of three racemic drugs using the microfluidic chip-CE device developed.
引用
收藏
页码:2962 / 2969
页数:8
相关论文
共 50 条
  • [31] Central composite design for the rapid optimisation of ruggedness and chiral separation of amlodipine in capillary electrophoresis
    Small, TS
    Fell, AF
    Coleman, MW
    Berridge, JC
    CHIRALITY, 1995, 7 (04) : 226 - 234
  • [32] Determination of selenomethionine in selenium-enriched yeast using capillary electrophoresis on-line coupled with electrochemiluminescence detection
    Deng, Biyang
    Shi, Aihong
    Li, Linqiu
    Xie, Fang
    Lu, Hua
    Xu, Quanxiu
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 279 - 283
  • [33] Pharmacokinetics and residues of tetracycline in crucian carp muscle using capillary electrophoresis on-line coupled with electrochemiluminescence detection
    Deng, Biyang
    Xu, Quanxiu
    Lu, Hua
    Ye, Li
    Wang, Yingzi
    FOOD CHEMISTRY, 2012, 134 (04) : 2350 - 2354
  • [34] Optimization using a factorial design for the separation of trandolapril and verapamil by capillary electrophoresis
    Capella-Peiro, MariaElisa
    Font-Rubert, Manolo
    Alvarez-Rodriguez, Lluis
    Esteve-Romero, Josep
    Durgbanshi, Abhilasha
    Bose, Devasish
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (20) : 2975 - 2988
  • [35] Determination of selenomethionine in selenium-enriched yeast using capillary electrophoresis on-line coupled with electrochemiluminescence detection
    Biyang Deng
    Aihong Shi
    Linqiu Li
    Fang Xie
    Hua Lu
    Quanxiu Xu
    Microchimica Acta, 2009, 165 : 279 - 283
  • [36] Optimisation for the separation of the oligosaccharide, sodium Pentosan Polysulfate by reverse polarity capillary zone electrophoresis using a central composite design
    Prochazka, S
    Mulholland, M
    Lloyd-Jones, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (01) : 133 - 141
  • [39] Optimization of micellar electrokinetic capillary chromatography method using central composite design for the analysis of components in Yangwei granule
    Wang, Shu-fang
    Fang, Hai-yan
    Qu, Hai-bin
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2011, 12 (03): : 193 - 200
  • [40] Optimization of micellar electrokinetic capillary chromatography method using central composite design for the analysis of components in Yangwei granule
    Shufang WANGHaiyan FANGHaibin QU Pharmaceutical Informatics InstituteZhejiang UniversityHangzhou China
    Journal of Zhejiang University-Science B(Biomedicine & Biotechnology), 2011, (03) : 193 - 200