Assessment of methods for calculating fire resistance of a steel beam

被引:0
|
作者
Skejic, Davor [1 ]
Rogic, Ivana [2 ]
Situm, Ana [3 ]
Lange, David [4 ]
Bostrom, Lars [5 ]
机构
[1] Sveuciliste Zagrebu, Gradevinski Fak, Zagreb, Croatia
[2] Seele GmbH, Gersthofen, Germany
[3] F2k Ingenieure Fries Kurschner Kobler GmbH, Stuttgart, Germany
[4] Sveuciliste Queensland, Gradevinski Fak, Brisbane, Qld, Australia
[5] RISE Svedski Inst Znanost, Boras, Sweden
来源
GRADEVINAR | 2018年 / 70卷 / 03期
关键词
fire resistance; steel beam; calculation methods; round robin study;
D O I
10.14256/JCE.2211.2017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experience shows that the assessment of fire resistance of steel elements based on European standards is conservative, while advanced methods are complex and time consuming. The analysis of existing methods for the tested steel beam exposed to bending and standard ISO fire was conducted in the scope of the international Round Robin study. The comparison of results shows that advanced methods provide non-uniform assessments. Nevertheless, advanced methods are necessary for improving standard methods that overestimate fire resistance of this "trivial" problem.
引用
收藏
页码:159 / 169
页数:11
相关论文
共 50 条
  • [31] FIRE RESISTANCE OF FIRE-RESISTANT STEEL COLUMNS
    SAKUMOTO, Y
    YAMAGUCHI, T
    OKADA, T
    YOSHIDA, M
    TASAKA, S
    SAITO, H
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (04): : 1103 - 1121
  • [32] PROBABILITY-BASED CRITICAL TEMPERATURE ASSESSMENT FOR SIMPLE STEEL BEAM EXPOSED TO FIRE
    Maslak, M.
    ARCHIVES OF CIVIL ENGINEERING, 2020, 66 (03) : 675 - 692
  • [33] Numerical assessment of structural assembly between steel beam and CFT columns under fire
    Carvalho Lopes, F. R.
    Santiago, A.
    Simoes da Silva, L.
    Santos da Silva, J. G.
    COST ACTION C26: URBAN HABITAT CONSTRUCTIONS UNDER CATASTROPHIC EVENTS, 2010, : 195 - 200
  • [34] Fire resistance performance of glulam beam
    Chen Chang-kun
    Yang Jian
    Chen Jie
    Zeng Jia-wei
    Wang Wei-yu
    Zhao Xiao-long
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2017, 24 (04) : 929 - 936
  • [35] Fire resistance performance of glulam beam
    Chang-kun Chen
    Jian Yang
    Jie Chen
    Jia-wei Zeng
    Wei-yu Wang
    Xiao-long Zhao
    Journal of Central South University, 2017, 24 : 929 - 936
  • [36] Fire resistance performance of glulam beam
    陈长坤
    杨建
    陈杰
    曾嘉伟
    王玮玉
    赵小龙
    Journal of Central South University, 2017, 24 (04) : 929 - 936
  • [37] PREDICTION OF THE FIRE RESISTANCE OF INSULATED STEEL
    MELINEK, SJ
    FIRE SAFETY JOURNAL, 1989, 14 (03) : 127 - 134
  • [38] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (03): : 82 - 94
  • [39] FIRE RESISTANCE OF STRUCTURAL-STEEL
    LIE, TT
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1978, 15 (04): : 116 - 125
  • [40] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    STETINA, HJ
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (04): : 134 - 136