An evaluation of image noise variance for time-of-flight PET

被引:0
|
作者
Watson, Charles C. [1 ]
机构
[1] Siemens Med Solut Mol Imaging, Knoxville, TN 37932 USA
关键词
POSITRON-EMISSION-TOMOGRAPHY; RECONSTRUCTION; SYSTEMS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a simple theoretical framework for linear time-of-flight (TOF) reconstruction and evaluate several alternative TOF filters. We implement a capability for direct computation of TOF noise variance images and evaluate the gain in image variance for TOF vs. non-TOF for 1.26 nsec TOF resolution on the Siemens biograph HiRez PET/CT. The variance calculation is validated by comparing to pixel variances computed from replicated synthetic data. TOF reconstruction does not give a uniform improvement in image noise variance, but improves variance more toward the periphery of an object than at its center. The TOF performance gain depends on how random coincidences are processed, and is greater when the randoms fraction is higher, or when randoms smoothing is not employed. We confirm that TOF gain is greater for larger objects than for smaller ones, but find discrepancies with the D/Delta x rule of thumb. With 1.26 nsec resolution on the HiRez, TOF image noise gain factors (non-TOF/TOF variance) range from 1.5 to 2.2 on the measured data at hand. We predict that an improvement in TOF resolution by a factor of 2 (to 600 psec) could improve image variance on this machine by an additional factor of 1.8. We find that confidence weighted TOF reconstruction under-performs non-TOF reconstruction for objects whose diameters are small compared to the TOF resolution.
引用
收藏
页码:2041 / 2045
页数:5
相关论文
共 50 条
  • [22] Evaluation of Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET
    Wang, Jingnan
    Wang, Tong
    Zhu, Wenjia
    Zhang, Yue
    Li, Nan
    Zhang, Hui
    Huo, Li
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [23] Clinical evaluation of a prototype time-of-flight PET/CT system
    Kempf, Brad
    Nathan, Mark
    Rohren, Eric
    Peller, Patrick
    Murphy, Robert
    Lowe, Val
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [24] Effect of time-of-flight in PET image reconstruction on standardized uptake value
    Sawamoto, Hirofumi
    Abe, Koichiro
    Baba, Shingo
    Tanabe, Yoshitaka
    Maruoka, Yasuhiro
    Sasaki, Masayuki
    Honda, Hiroshi
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [25] Commissioning and First Image Reconstruction with a New Time-of-Flight PET Prototype
    Brandt, Ole
    Munwes, Yonathan
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [26] TIME-OF-FLIGHT DEPTH IMAGE DENOISING USING PRIOR NOISE INFORMATION
    Edeler, T.
    Ohliger, K.
    Hussmann, S.
    Mertins, A.
    2010 IEEE 10TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS (ICSP2010), VOLS I-III, 2010, : 119 - +
  • [27] Improving time resolution in time-of-flight PET
    Conti, Maurizio
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S194 - S198
  • [28] Clinical impact of time-of-flight PET
    Soussan, M.
    Galas, J-L
    Ouvrier, M-J
    Pop, G.
    Neuman, A.
    Weinmann, P.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (07): : 401 - 405
  • [29] Update on Time-of-Flight PET Imaging
    Surti, Suleman
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 98 - 105
  • [30] OPTIMIZATION OF DETECTORS FOR TIME-OF-FLIGHT PET
    Moszynski, Marek
    Szczesniak, Tomasz
    WORKSHOP ON TIMING DETECTORS: ELECTRONICS, MEDICAL AND PARTICLE PHYSICS APPLICATIONS, 2010, 4 (01): : 59 - 64