Development of Exposed Environment of Overhead Transmission Lines on Mice

被引:0
|
作者
Geng, Duyan [1 ]
Xu, Guizhi [1 ]
Yu, Hongli [1 ]
Li, Cuihuan [1 ]
Yang, Qingxin [1 ]
Yan, Weili [1 ]
机构
[1] Hebei Univ Technol, Key Lab Electromagnet Field & Elect Apparat Relia, Tianjin 300130, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to study the responses that occur in mice chronically exposed to power frequency electromagnetic fields of transmission lines, an exposed environment was constructed in laboratory. Charge simulation method and Biot-Savart law have respectively been adopted to compute the three-dimensional electric and magnetic fields of the exposed environment. Both methods are programmed using the MATLAB software. Simulations indicate that the maximum intensity of electric field, found at the level of 4 centimeters above ground (the height of white mice), can reach up to 0.85 kilometer voltage per meter (kV/m) at ground level, and the magnetic flux density can amount to 58 milli-Gauss (mG). Compared with typical overhead transmission lines, the paper concluded that the exposed condition for mice exposed to has been approached effectively and closely.
引用
收藏
页码:166 / 169
页数:4
相关论文
共 50 条
  • [21] Research and Development of On-line Monitoring System for HV Overhead Transmission Lines
    Gao, Zhilong
    Wang, Dongtao
    Cai, Xiaocen
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLIED SCIENCE AND ENGINEERING INNOVATION, 2015, 12 : 335 - 338
  • [22] Mechanical Calculation of Power Lines and Strands in Overhead Transmission Lines
    Li, Yongping
    Liu, Yu
    Zhang, Jibin
    4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENERGY AND NETWORKS (ICEEN 2016), 2016, 50
  • [23] Fault Identification Technology For Overhead Transmission Lines
    Li Fan
    Zhou Longwu
    Li Yanglin
    Rao Binbin
    Zhang Yu
    Zou Jianzhang
    Hu Jing
    Kuang Yanjun
    2018 3RD INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE), 2018, : 443 - 447
  • [24] Estimation of Lightning Incidence to Overhead Transmission Lines
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1855 - 1865
  • [25] STANDARDIZATION OF OVERHEAD POWER TRANSMISSION-LINES
    BUDZKO, IA
    VENIKOV, VA
    NEKRASOV, AM
    ASTAKHOV, YN
    CHEREMISIN, NM
    ZUBKO, VM
    BLOK, WM
    ELECTRICAL TECHNOLOGY, 1984, (01): : 31 - 41
  • [26] OVERHEAD TRANSMISSION-LINES - REFURBISHMENT AND DEVELOPMENTS
    FERGUSON, JM
    GIBBON, RR
    POWER ENGINEERING JOURNAL, 1994, 8 (03): : 109 - 118
  • [27] AUTOMATIC FAULT LOCATION ON OVERHEAD TRANSMISSION LINES
    JAMIESON, E
    ELECTRICAL REVIEW, 1969, 185 (23): : 833 - &
  • [28] Automatic Design of Overhead Transmission Lines.
    Olbrycht, Leslaw
    Przeglad Elektrotechniczny, 1981, 57 (3-4): : 108 - 110
  • [29] Statistical variation of currents in overhead transmission lines
    Morgan, VT
    ELECTRIC POWER SYSTEMS RESEARCH, 2001, 57 (02) : 59 - 64
  • [30] Overhead Quasi-Coaxial Transmission Lines
    Trainotti, Valentino
    Fano, Walter G.
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2009, 51 (06) : 93 - 101