A High Sensitivity Optical Fiber Interferometer Sensor for Acoustic Emission Detection of Partial Discharge in Power Transformer

被引:38
|
作者
Zhou, Hong-yang [1 ,2 ]
Ma, Guo-ming [1 ,2 ]
Zhang, Meng [1 ,2 ]
Zhang, Han-chi [3 ]
Li, Cheng-rong [1 ,2 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Beijing Key Lab High Voltage & EMC, Beijing 102206, Peoples R China
[3] Aalborg Univ, Dept Energy Technol, DK-9100 Aalborg, Denmark
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Optical fiber sensors; Optical fibers; Acoustics; Partial discharges; Power transformers; Sensitivity; Power transformer; partial discharge; Michelson interferometer; optical fiber sensor; fiber coil effects; TRANSDUCER; LOCATION;
D O I
10.1109/JSEN.2019.2951613
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose a Michelson ultrasonic sensing system for detecting the acoustic emission generated by the partial discharge in power transformer. In order to guide the sensor head design in the sensing system for high sensitivity, a theoretical model is established to investigate the effects of the sensor head dimensions on the response sensitivity. After that, an optimized sensor head is designed. In the frequency range from 80 kHz to 200 kHz, whether the PZT sensor is installed in the oil or on the tank, the average response sensitivity of the proposed sensing system is higher than that of the conventional PZT system. When the distance between the sensor head and ultrasonic source is 300 mm in oil, the average detection limit of the Michelson ultrasonic sensing system is about 0.26 Pa, which is about 18.6% of that of the PZT system. Moreover, experiment results show that the detectable partial discharge initial voltage for the proposed optical system is 21.5% lower than that for the PZT system. The enhanced sensitivity makes the Michelson ultrasonic sensing system a potential method to detect the small defects in power transformer.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 50 条
  • [11] Sensitivity check of internal sensor for power transformer partial discharge measurements
    Agoris, P. D.
    Meijer, S.
    Smit, J. J.
    Lopez-Roldan, J.
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 230 - +
  • [12] High-sensitivity and High-consistency Extrinsic Fiber Fabry-Perot Partial Discharge Induced Acoustic Emission Sensor
    Chen Q.
    Li Q.
    Li Z.
    Zhang W.
    Zhao H.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (11): : 4747 - 4756
  • [13] Sensitivity Verification and Application of UHF Sensor for Partial Discharge Measurement in High Voltage Power Transformer
    Jung, J. R.
    Hwang, K. R.
    Kim, Y. M.
    Lyu, E. T.
    Yang, H. J.
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 277 - 280
  • [14] Optical Fiber Ultrasonic Detection Technology for Partial Discharge in Power Transformer and New Multiplexing Method
    Ma G.
    Zhou H.
    Liu Y.
    Gao S.
    Xia Y.
    Zhang W.
    Zhang Z.
    He R.
    Peng G.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (05): : 1768 - 1780
  • [15] Preliminary Study on a Fiber Optic Extrinsic Fabry-Perot Interferometer Sensor of Acoustic Detection for Partial Discharge
    Si Wen-Rong
    Fu Chen-Zhao
    Gao Kai
    Huang Hua
    Yuan Peng
    2018 INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA), 2018, : 155 - 158
  • [16] Partial Discharge Diagnostics in Power and Instrument Transformer Based on Acoustic Emission Method
    Nicoara, Tania
    Marinescu, Andrei
    Patru, Ion
    2016 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2016,
  • [17] Partial Discharge Localization and Classification Using Acoustic Emission Analysis in Power Transformer
    Mohammadi, Ezatollah
    Niroomand, Mehdi
    Rezaeian, Mandie
    Amini, Zahra
    INTELEC 09 - 31ST INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 2009, : 1186 - 1191
  • [18] Ultra-High SNR Demodulation Method for Optical Fiber Sensors Applied in Power Transformer Partial Discharge Detection
    Qiao, Jixian
    Zhang, Weichao
    Wang, Yanqi
    Shao, Qibing
    Cai, Jianlong
    Zhao, Hong
    SENSORS, 2022, 22 (08)
  • [19] Detection of acoustic emission wave by using optical fiber sensor during single pulse discharge
    Akematsu, Yoshiaki
    Kageyama, Kazuro
    Mohri, Naotake
    Murayama, Hideaki
    Matsuo, Masako
    ADVANCED SENSOR TECHNOLOGIES FOR NONDESTRUCTIVE EVALUATION AND STRUCTURAL HEALTH MONITORING II, 2006, 6179
  • [20] ACOUSTIC SENSITIVITY OF FIBER-OPTICAL INTERFEROMETER
    BUTUSOV, MM
    ERMAKOVA, NV
    URVANTSEVA, NL
    OPTIKA I SPEKTROSKOPIYA, 1982, 53 (02): : 193 - 194