Novel system for storage of buffy-coat-derived platelet concentrates in a glucose-based platelet additive solution: parameters and metabolism during storage and comparison to plasma

被引:22
|
作者
Gyongyossy-Issa, M. I. C. [2 ]
Zhang, J. G. [2 ]
Culibrk, B. [2 ]
Hunter, F.
Levin, E. [2 ]
Scammell, K.
Weiss, S.
Holmes, D. L. [1 ]
Holme, S. [1 ]
机构
[1] Pall Med, Covina, CA USA
[2] UBC Ctr Blood Res, Canadian Blood Serv, Vancouver, BC V6T 1Z3, Canada
基金
加拿大健康研究院;
关键词
platelet storage; platelet additive solution; PAS-G; buffy-coat platelets; platelet metabolism; IN-VITRO; SYNTHETIC MEDIUM; NEW-GENERATION; SOLUTION-II; TRANSFUSION; IMPLEMENTATION; MULTICENTER; EXPERIENCE; POTASSIUM; MAGNESIUM;
D O I
10.1111/j.1423-0410.2009.01196.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In Europe, buffy-coat processing allows for the use of platelet additive solutions (PAS). These solutions, however, have long been questioned for their lack of glucose, a potentially essential nutrient for platelet storage. Using a novel, practical, two-part system for incorporation of glucose into an additive solution (PAS-G), this study compares platelet storage in plasma to storage in PAS-G. Study Design and Methods A paired study design of platelet concentrates (PC) were prepared from leucoreduced pools of eight buffy coats (BCP) split into two equal pools, with suspension in autologous plasma, or PAS-G. On days 2, 5, 7 and 9 of storage, samples were tested using standard in vitro platelet parameters. Data were analysed by paired Student's t-tests. Results During storage, PCs in PAS-G maintain a quality profile that is strikingly similar to PCs stored in plasma in terms of platelet activation (CD62) morphology score, swirl, glucose metabolism and pH. However, PCs in PAS-G perform lower (P < 0 center dot 05) in the %ESC and %HSR assays. Conclusion PAS-G's novel presentation allows incorporation of glucose into the additive solution so that it is roughly equivalent to plasma for the maintenance of buffy-coat PCs.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 50 条
  • [31] Comparison of two automated blood fractionation systems in the routine preparation of leucoreduced pooled buffy coat derived platelet concentrates in additive solution
    Lozano, M
    Mazzara, R
    Ordinas, A
    TRANSFUSION, 2004, 44 (09) : 67A - 67A
  • [32] Lipidomic analysis of differently prepared platelet concentrates in additive solution during storage
    Duchez, Anne -Claire
    Fauteux-Daniel, Sebastien
    Ebermeyer, Theo
    Heestermans, Marco
    Arthaud, Charles-Antoine
    Eyraud, Marie-Ange
    Prier, Amelie
    Audoux, Estelle
    Portais, Jean-Charles
    Bertrand-Michel, Justine
    Garraud, Olivier
    Hamzeh-Cognasse, Hind
    Boilard, Eric
    Cognasse, Fabrice
    BLOOD TRANSFUSION, 2023, 21 (05) : 409 - 421
  • [33] Evaluation of platelet function during extended storage in additive solution, prepared in a new container that allows manual buffy-coat platelet pooling and leucoreduction in the same system
    Maria Plaza, Eva
    Luisa Lozano, Maria
    Sanchez Guiu, Isabel
    Manuel Egea, Jose
    Vicente, Vicente
    Collantes de Teran, Laura
    Rivera, Jose
    BLOOD TRANSFUSION, 2012, 10 (04) : 480 - 489
  • [34] Platelet storage lesion of WBG-reduced, pooled, buffy coat-derived platelet concentrates prepared in three in-process filter/storage bag combinations
    Krailadsiri, P
    Seghatchian, J
    Williamson, LM
    TRANSFUSION, 2001, 41 (02) : 243 - 250
  • [35] Storage of platelet-rich plasma-derived platelet concentrate pools in plasma and additive solution
    Sweeney, J
    Kouttab, N
    Holme, S
    Kurtis, J
    Cheves, T
    Nelson, E
    TRANSFUSION, 2006, 46 (05) : 835 - 840
  • [36] Storage of buffy-coat-derived platelets in additive solution: in vitro effects on platelets of the air bubbles and foam included in the final unit
    Sandgren, Per
    Saeed, Kharija
    BLOOD TRANSFUSION, 2011, 9 (02) : 182 - 188
  • [37] Cold storage of platelets in additive solution: the impact of residual plasma in apheresis platelet concentrates
    Marini, Irene
    Aurich, Konstanze
    Jouni, Rabie
    Nowak-Harnau, Stefanie
    Hartwich, Oliver
    Greinacher, Andreas
    Thiele, Thomas
    Bakchoul, Tamam
    HAEMATOLOGICA, 2019, 104 (01) : 207 - 214
  • [38] Comparison of two semi-automated devices for preparing leukoreduced pooled buffy-coat derived pooled platelet concentrates in additive solution
    Cid, J.
    Lozano, M.
    Ramiro, L.
    Escolar, G.
    Puig, L. L.
    Pla, R. P.
    VOX SANGUINIS, 2008, 95 : 318 - 318
  • [39] Storage of apheresis and pooled buffy-coat platelet concentrates treated with pathogen inactivation using the intercept blood system
    Schlenke, P.
    Franck, V.
    Lin, L.
    Kirchner, H.
    VOX SANGUINIS, 2006, 91 : 178 - 178
  • [40] Are all leucodepleted platelet concentrates equivalent? Comparison of Cobe LRS Turbo, haemonetics MCS plus LD, and filtered pooled buffy-coat-derived platelets
    Krailadsiri, P
    Seghatchian, J
    VOX SANGUINIS, 2000, 78 (03) : 171 - 175