Quartz crystal microbalance based biosensor for rapid and sensitive detection of maize chlorotic mottle virus

被引:32
|
作者
Huang, Xin [1 ]
Xu, Jianmin [1 ]
Ji, Hai-Feng [2 ]
Li, Guifen [1 ]
Chen, Hongjun [1 ]
机构
[1] Chinese Acad Inspect & Quarantine, Inst Plant Quarantine, Beijing 100029, Peoples R China
[2] Drexel Univ, Dept Chem, Philadelphia, PA 19010 USA
关键词
SELF-ASSEMBLED MONOLAYERS; POLYELECTROLYTE MULTILAYERS; PROTEIN MOLECULES; RESONATOR; IMMOBILIZATION; LIQUID; CHINA;
D O I
10.1039/c4ay00292j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we report a biosensor based on a quartz crystal microbalance ( QCM) for the selective and sensitive detection of maize chlorotic mottle virus (MCMV). A mixture of 10 : 1 3-mercaptopropanoic acid and 11-mercaptoundecanoic acid was applied on gold surfaces of QCM crystals to form a selfassembled monolayer, and an anti-MCMV antibody was crosslinked on the surface for specific recognition of MCMV. The frequency change of the QCM crystal is a function of the concentration of MCMV with a response range from 250 ng mL(-1) to 10 mg mL(-1). The standard curve is R2 0.997, indicating a high reproducibility in MCMV detection. The detection limit is approximately 250 ng mL(-1), which is similar to that of the existing enzyme-linked immunosorbent assay (ELISA) method. The QCM sensor showed highly specific and sensitive recognition for both purified MCMV and crude extracts from corn leaf samples.
引用
收藏
页码:4530 / 4536
页数:7
相关论文
共 50 条
  • [41] First Report of Maize chlorotic mottle virus and Maize Lethal Necrosis in Kenya
    Wangai, A. W.
    Redinbaugh, M. G.
    Kinyua, Z. M.
    Miano, D. W.
    Leley, P. K.
    Kasina, M.
    Mahuku, G.
    Scheets, K.
    Jeffers, D.
    PLANT DISEASE, 2012, 96 (10) : 1582 - 1583
  • [42] Maize catalases localized in peroxisomes support the replication of maize chlorotic mottle virus
    Zhiyuan Jiao
    Juan Wang
    Yiying Tian
    Siyuan Wang
    Xi Sun
    Siqi Li
    Wendi Ma
    Tao Zhou
    Zaifeng Fan
    Phytopathology Research, 3
  • [43] Biosensor for Rapid and Sensitive Detection of Influenza Virus
    Jong Min Yang
    Kyeong Rok Kim
    Chang Sup Kim
    Biotechnology and Bioprocess Engineering, 2018, 23 : 371 - 382
  • [44] Biosensor for Rapid and Sensitive Detection of Influenza Virus
    Yang, Jong Min
    Kim, Kyeong Rok
    Kim, Chang Sup
    BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2018, 23 (04) : 371 - 382
  • [45] Detection of Salmonella Typhimurium with Gold Nanoparticles Using Quartz Crystal Microbalance Biosensor
    Min, Hyun Jung
    Mina, Hansel A.
    Deering, Amanda J.
    Robinson, J. Paul
    Bae, Euiwon
    SENSORS, 2022, 22 (22)
  • [46] Maize Seed Contamination and Seed Transmission of Maize Chlorotic Mottle Virus in Kenya
    Kimani, Esther N.
    Kiarie, Samuel M.
    Micheni, Cyrus
    Muriki, Laureen G.
    Miano, Douglas W.
    Macharia, Isaac
    Munkvold, Gary P.
    Muiru, William M.
    Prasanna, B. M.
    Wangai, Anne
    PLANT HEALTH PROGRESS, 2021, 22 (04): : 496 - 502
  • [47] An enzyme-free quartz crystal microbalance biosensor for sensitive glucose detection in biological fluids based on glucose/dextran displacement approach
    Tang, Dianping
    Li, Qunfang
    Tang, Juan
    Su, Biling
    Chen, Guonan
    ANALYTICA CHIMICA ACTA, 2011, 686 (1-2) : 144 - 149
  • [48] Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor
    Yao, Chunyan
    Qu, Ling
    Fu, Weiling
    SENSORS, 2013, 13 (06): : 6946 - 6956
  • [49] Visual and Super-Sensitive Detection of Maize Chlorotic Mottle Virus by Dot-ELISA and Au Nanoparticle-Based Immunochromatographic Test Strip
    Zhang, Cui
    Guo, Mengmeng
    Dong, Jinxi
    Liu, Li
    Zhou, Xueping
    Wu, Jianxiang
    VIRUSES-BASEL, 2023, 15 (07):
  • [50] Real-time TaqMan RT-PCR for detection of maize chlorotic mottle virus in maize seeds
    Zhang, Yongjiang
    Zhao, Wenjun
    Li, Mingfu
    Chen, Hongjun
    Zhu, Shuifang
    Fan, Zaifeng
    JOURNAL OF VIROLOGICAL METHODS, 2011, 171 (01) : 292 - 294