Computational evaluation of dose distribution for BNCT treatment combined with X-ray therapy or proton beam therapy

被引:3
|
作者
Takada, Kenta [1 ,2 ]
Kumada, Hiroaki [2 ]
Matsumura, Akira [2 ]
Sakurai, Hideyuki [2 ]
Sakae, Takeji [2 ]
机构
[1] Gunma Prefectural Coll Hlth Sci, Dept Radiol Technol, 323-1 Kamiokimachi, Maebashi, Gunma 3710052, Japan
[2] Univ Tsukuba, Fac Med, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058575, Japan
关键词
PHITS simulation; BNCT; Combined radiotherapy; Dose evaluation system; Tsukuba Plan; NEUTRON-CAPTURE THERAPY; MICRODOSIMETRIC KINETIC-MODEL; PARTICLE; CANCER;
D O I
10.1016/j.apradiso.2020.109295
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, we performed Monte Carlo simulations to accurately reflect the beam delivery systems including patient-specific irradiation devices of X-ray and proton beam therapies. The dose distributions obtained from the simulations for X-rays or proton beams were successfully combined to the dose distribution of boron neutron capture therapy (BNCT), which was calculated by a treatment planning system called Tsukuba Plan. The results demonstrate the feasibility of dose evaluation for BNCT combined with other radiotherapy modalities using the Tsukuba Plan.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Proton therapy in adjuvant treatment of gastric cancer: Planning comparison with advanced x-ray therapy and feasibility report
    Dionisi, Francesco
    Avery, Stephen
    Lukens, John N.
    Ding, Xuanfeng
    Kralik, John
    Kirk, Maura
    Roses, Robert E.
    Amichetti, Maurizio
    Metz, James M.
    Plastaras, John P.
    ACTA ONCOLOGICA, 2014, 53 (10) : 1312 - 1320
  • [32] The treatment of sterility with "small dose" x ray therapy
    Friedman, M
    Finkler, R
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1942, 43 : 852 - 857
  • [33] Evaluation of Computed Tomography X-Ray Beam Dose Profiles
    Civa, Lejla M.
    Beganovic, Adnan
    Redzic, Mahira
    Lasic, Ivan
    Gazdic-Santic, Maja
    Skopljak-Beganovic, Amra
    Jasic, Rahima
    Vegar-Zubovic, Sandra
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, CMBEBIH 2019, 2020, 73 : 137 - 141
  • [34] MONTE CARLO SIMULATION FOR EVALUATION OF DOSE DISTRIBUTION IN PROTON THERAPY
    Sardari, Dariush
    Salimi, Ehsan
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (01) : 148 - 156
  • [35] AN X-RAY TUBE MOUNTING FOR CONVERGENT BEAM THERAPY GIVING HIGH PERCENTAGE DEPTH DOSE
    KOLLIBAY, W
    BRITISH JOURNAL OF RADIOLOGY, 1950, 23 (275): : 653 - 655
  • [36] Erratum to: Interactive X-ray and proton therapy training and simulation
    Felix G. Hamza-Lup
    Shane Farrar
    Erik Leon
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1685 - 1685
  • [37] Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams
    Li, XA
    Ma, CM
    Salhani, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (12): : 2561 - 2568
  • [38] A Critical Review of Radiation Therapy: From Particle Beam Therapy (Proton, Carbon, and BNCT) to Beyond
    Matsumoto, Yoshitaka
    Fukumitsu, Nobuyoshi
    Ishikawa, Hitoshi
    Nakai, Kei
    Sakurai, Hideyuki
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (08):
  • [39] DISTRIBUTION OF SCATTERED RADIATION IN SUPERFICAL X-RAY THERAPY
    Medvedevas, Nikolajus
    Adliene, Diana
    Laurikaitiene, Jurgita
    MEDICAL PHYSICS IN THE BALTIC STATES, 2010, (02): : 133 - +
  • [40] Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging
    Zhang, Ye
    Knopf, A.
    Tanner, C.
    Boye, D.
    Lomax, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24): : 8621 - 8645